manualshive.com logo in svg
background image

4

Operating Instructions

Oilless Stationary Compressors

LUBRICATION

This is an oilless product and 

DOES

NOT

require lubrication to operate.

BREAK-IN PROCEDURE 

Do not attach air 
chuck or other tool

to open end of hose until start-up has
been completed and unit checks OK.

IMPORTANT:

Do not operate

compressor before reading instructions
or damage may result. 
1. Turn regulator fully clockwise to

open air flow.

2. Turn switch to OFF position and plug

in power cord.

3. Turn switch to AUTO position and

run unit for 30 minutes to break in
the pump parts.

4. Turn regulator knob fully

counterclockwise. Compressor will 
build to maximum preset pressure
and shut off.

5. Turn regulator knob clockwise to

cause air to bleed off. Compressor
will restart at a preset pressure.

6. Turn regulator knob

counterclockwise to shut off the air
and turn switch to Off position.

7. Attach chuck or other tool to open

end of hose. Turn the regulator on.

In the AUTO position, the compressor
pumps air into the tank. It shuts off
automatically when unit reaches its
maximum preset pressure. In the OFF
position, the pressure switch cannot
function and the compressor will not
operate. This switch should be in the
OFF position when connecting or
disconnecting the power cord from the
electrical outlet.

ASME SAFETY VALVE

Do not remove or 
attempt to adjust

the safety valve!

This valve should be
checked under
pressure occasionally
by pulling the ring by
hand. If air leaks after
ring has been

Figure 3

MOISTURE IN COMPRESSED AIR

Moisture in compressed air will form
into droplets as it comes from an air
compressor pump. When humidity is
high or when a compressor is in
continuous use for an extended
period of time, this moisture will
collect in the tank. When using a
paint spray or sandblast gun, this
water will be carried from the tank
through the hose, and out of the
gun as droplets mixed with the spray
material.

IMPORTANT:  

This condensation

will cause water spots in a paint
job, especially when spraying other
than water based paints. If
sandblasting, it will cause the sand
to cake and clog the gun, rendering
it ineffective. A filter in the air line
(MP3105), located as near to the
gun as possible, will help eliminate
this moisture.

Drain
Petcock

Safety
Valve

Pressure
Switch

Regulator

Check Valve
(Opposite Side)

Off

Auto

Air Hose
Attachment

Discharge Tube

(Opposite Side)

Figure 4

power cord from the electrical outlet or
when changing air tools.

Regulator

- The regulator controls the

amount of air pressure released at the
hose outlet.

ASME Safety Valve

- This valve

automatically releases air if the tank
pressure exceeds the preset maximum.

Discharge tube

- This tube carries

compressed air from the pump to the
check valve. This tube becomes very hot
during use. To avoid the risk of severe
burns, never touch the discharge tube.

Check valve

- One-way valve that

allows air to enter the tank, but
prevents air in the tank from flowing
back into the compressor pump.

Drain Petcock

- This valve is located on

the bottom of the tank. Use this valve
to drain moisture from the tank daily
to reduce the risk of corrosion.

Reduce tank pressure below 10 PSI,
then drain moisture from tank daily to
avoid tank corrosion. Drain moisture
from tank(s) by opening the drain
petcock located underneath the tank.

Figure 5

Operation 

(Continued)

Содержание WL6000 Series

Страница 1: ...below the pump in the space below Model No ____________________ Serial No ____________________ Date of purchase _________________ Retain these numbers for future reference Q U A L I T YASSURANCE PR O G R A M Need Assistance Call Us First 1 800 543 8622 Oilless Stationary Compressors questions damaged or missing parts please call 1 800 543 6400 for customer assistance or call the nearest Campbell H...

Страница 2: ...ulting in damage from rupture or explosion Always replace worn or damaged tanks Drain liquid from tank daily 12 Tanks rust from moisture build up which weakens the tank Make sure to drain tank regularly and inspect periodically for unsafe conditions such as rust formation and corrosion 13 Fast moving air will stir up dust and debris which may be harmful Release air slowly when draining moisture or...

Страница 3: ...tage indicated on motor nameplate and meet all electrical codes for this minimum 2 Use a slow blow fuse or a circuit breaker Overheating short circuiting and fire damage will result from inadequate wiring etc NOTE 120 volt 15 amp units can be operated on a 120 volt circuit under the following conditions a No other electrical appliances or lights are connected to the same branch circuit b Voltage s...

Страница 4: ...plets as it comes from an air compressor pump When humidity is high or when a compressor is in continuous use for an extended period of time this moisture will collect in the tank When using a paint spray or sandblast gun this water will be carried from the tank through the hose and out of the gun as droplets mixed with the spray material IMPORTANT This condensation will cause water spots in a pai...

Страница 5: ...2 Clogged air filter 3 Lack of proper ventilation If the thermal overload protector is actuated the motor must be allowed to cool down before start up is pos sible The motor will automatically restart without warning if left plugged into electrical outlet and unit is turned on TORQUE REQUIREMENTS Connecting rod bolt 20 in Ibs Compressor hd bolts 100 110 in Ibs Motor bolts 35 in Ibs Mounting bolts ...

Страница 6: ...cause of problem 4 Motor will restart when cool 5 Replace 6 Remove and replace check valve Do not disassemble check valve with air in tank bleed tank 1 Check connections check with voltmeter 2 Replace motor 3 Replace or repair Do not disassemble check valve with air in tank bleed tank 1 Check for proper fuse use time delay fuse Disconnect other electrical appliances from circuit or operate compres...

Страница 7: ...heck valve assembly clean or replace Do not disassemble check valve with air in tank bleed tank 1 Clean or replace 2 Replace leaking components or tighten as necessary 3 Have authorized service representative repair unit 4 Replace 5 Replace 1 Drain tank 2 Move to area of less humidity use air line filter 1 Replace switch 2 Decrease air usage compressor not large enough for air requirement 1 Drain ...

Страница 8: ...d to maintain the product i e lubricants filters and gaskets etc G Gasoline engines and components are expressly excluded from coverage under this limited warranty The Purchaser must comply with the warranty given by the engine manufacturer which is supplied with the product H Additional items not covered under this warranty 1 All Compressors Maintenance records must be provided to make warranty c...

Страница 9: ... 1910 134 et ou Canadian Standards Associations CSA DÉNÉGATION DES GARANTIES SI LE COMPRESSEUR EST UTILISÉ POUR LES APPLICATIONS D AIR RESPIRABLE ET L ÉQUIPEMENT DE SÉCURITÉ EN CANALISATION ET D ALARME N EST PAS UTILISÉ SIMULTANÉMENT LES GARANTIES EN EXISTANCE SERONT ANNULÉES ET CAMPBELL HAUSFELD NIE TOUTE RESPONSABILITÉ POUR N IMPORTE QUELLE PERTE BLESSURE OU DOMMAGE DANGER MANUEL BUILT TO LAST T...

Страница 10: ...utilisation Réparer ou remplacer toutes pièces défectueuses avant l utilisation 8 Inspecter le degré de serrage de toutes attaches par intervalles régulières Ne jamais essayer de réparer ou de modifier un réservoir Le soudage perçage ou autre modifications peuvent affaiblir le réservoir et peuvent résulter en dommage de rupture ou d explosion Toujours remplacer un réservoir usé fendu ou endommagé ...

Страница 11: ...erre à ni une ni l autre borne plate Le fil avec l isolation qui a une surface externe verte avec ou sans rayures est le fil de terre Ne jamais brancher le fil vert ou vert et jaune à une borne électrisée 3 Si vous ne comprenez pas les instructions pour la mise à la terre ou si vous n êtes pas certains si le produit AVERTISSEMENT DANGER DANGER est mis à la terre correctement vérifier avec un élect...

Страница 12: ...eur accumulera la pression jusqu à ce qu il atteint la pression réglée d avance et s arrêtera 5 Tourner le bouton du régulateur à la droite en laissant de l air s échapper Le compresseur se remettra en marche à une pression réglée d avance 6 Tourner le bouton du régulateur à la gauche afin de couper l air et ensuite tourner l interrupteur à la position Off 7 Fixer un mandrin ou autre outil au bout...

Страница 13: ...pape DOIT être remplacée BOUTON DU RÉGULATEUR 1 Ce bouton règle la pression à un outil pneumatique ou à un pistolet pulvérisateur Voir Figure 5 2 La pression d air à la sortie est augmentée en tournant le bouton à la droite 3 La pression d air à la sortie est réduite en tournant le bouton à la gauche 4 Pour couper le débit d air tourner complètement à la gauche MANOMÈTRE RÉGLÉ DE SORTIE D AIR 1 Ce...

Страница 14: ... 6 Enlever et remplacer le clapet Ne pas démonter le clapet s il y a de l air dans le réservoir vidanger le réservoir 1 Inspecter les branchements vérifier avec un voltmètre 2 Remplacer le moteur 3 Remplacer ou réparer Ne pas démonter le clapet s il y a de l air dans le réservoir vidanger le réservoir 1 Vérifier le type de fusible utiliser un fusible à retardement Débrancher les autres appareils é...

Страница 15: ...l air dans le réservoir vidanger le réservoir 1 Nettoyer ou remplacer 2 Remplacer les pièces qui ont des fuites ou serrer 3 Faire réparer le modèle à un centre de service autorisé 4 Remplacer 5 Remplacer 1 Purger le réservoir 2 Déplacer à un endroit moins humide utiliser un filtre en canalisation d air 1 Remplacer 2 Réduire l utilisation d air le compresseur n est pas assez large pour la demande d...

Страница 16: ...rs à essence et les pièces détachées sont expressément exclus de cette garantie limitée L acheteur doit observer la garantie du fabricant de moteur qui est fournie avec le produit H Articles supplémentaires qui ne sont pas couverts sous cette garantie 1 Tous les Compresseurs Il est nécessaire de fournir le compte d entretien pour une réclamation de garantie a Toutes pièces détachées endommagées pe...

Страница 17: ... indica que hay una situación inmediata que LE OCASIONARIA la muerte o heridas de gravedad Esto le indica que hay una situación que PODRIA ocasionarle la muerte o heridas de gravedad Esto le indica que hay una situación que PODRIA ocasionarle heridas no muy graves Ésto le indica una información importante que de no seguirla le podría ocasionar daños al equipo Cuando desempaque la unidad inspección...

Страница 18: ... La circulación rápida de aire podría levantar polvo y desperdicios dañinos Siempre libere el aire lentamente para drenar el tanque o liberar la presión del sistema PRECAUCIONES PARA ROCIAR Nunca rocíe materiales inflamables cerca de llamas al descubierto o fuentes de ignición incluyendo el compresor 14 No fume mientras esté rociando pintura insecticidas u otras substancias inflamables 15 Use una ...

Страница 19: ...os terminales planos El alambre cuya superficie externa del aislante es verde con o sin rayas amarillas es el cable de conexión a tierra Nunca conecte los cables verdes o verde con rayas amarillas a un terminal con tensión 3 Consúltele a un electricista calificado o a un técnico de reparación en caso de que no comprenda bien las instrucciones o si tiene dudas de que esté conectado a tierra adecuad...

Страница 20: ...amente en sentido contrario al de las agujas del reloj para cerrar el flujo de aire y coloque el presostato en Off 7 Conecte un mandril o herramienta neumática a la manguera Encienda el regulador En la posición AUTO el compresor bombea aire hacia el tanque El compresor se apaga automáticamente cuando la unidad alcanza una presión máxima fijada de fábrica En la posición OFF el presostato no puede f...

Страница 21: ... ubicada debajo del tanque para drenarle toda la humedad 3 Apague el compresor póngalo en OFF y limpie el motor el tanque las líneas de aire y las aletas del sistema de enfriamiento del cabezal IMPORTANTE Debe colocar el com presor lo más lejos posible del área de trabajo según lo permita la longitudud de la manguera para evitar que el filtro se atasque FILTRO DE AIRE Cerciórese de que el filtro e...

Страница 22: ...lácelo 6 Desconecte y reemplace la válvula de chequeo Antes de desmantelar la válvula de chequeo purgue el aire del tanque 1 Chequée las conecciones chequée con un voltimetro 2 Reemplace el motor 3 Reemplácela o repárela Antes de desmantelar la válvula de chequeo purgue el aire del tanque 1 Cerciórese de que está usando el fusible adecuado use un fusible de acción retardada Desconecte los otros ar...

Страница 23: ...mantelar la válvula de chequeo purgue el aire del tanque 1 Límpielo o reemplácelo 2 Reemplace las tuberías que tengan fugas o apriételas según sea necessario 3 Un técnico especializado debe reparar el compresor 4 Reemplácelo 5 Reemplácelo 1 Drene el tanque 2 Mueva el compresor a una área menos húmeda use un filtro de aire incorporado a la línea 1 Reemplace el presostato 2 Disminuya el consumo de a...

Страница 24: ...tes filtros y empaques G Las piezas para motores eléctricos o de gasolina están específicamente excluídos de la cobertura de esta garantía limitada Éstos deben ser enviados por el comprador al fabricante original o a los centros de servicio autorizados por el fabricante para que se les den servicio H Artículos adicionales no cubiertos por esta garantía 1 Todos los compresores Debe suministrar los ...

Отзывы: