manualshive.com logo in svg
background image

2

Operating Instructions & Parts Manual

www.chpower.com

General Safety 

(Cont.)

Caution indicates 
a potentially haz-

ardous situation which, if not avoided,
MAY result in minor or moderate
injury.

Notice indicates 
important infor-

mation that, if not followed, may
cause damage to the equipment.

IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS

– To

reduce the risk of fire or explosion,
electrical shock and injury to per-
sons, read and understand all
instructions included in this manual.
Be familiar with the controls and
the proper usage of the equipment.

ELECTRICAL SHOCK HAZARD:
To prevent electrical shock,
observe the following guide-
lines at all times:

GROUNDING INSTRUCTIONS

This product must be grounded. In
the event of an electrical short cir-
cuit, grounding reduces the risk of
electric shock by providing an
escape wire for the electric current.
This product is equipped with a cord
having a grounding wire with an
appropriate grounding plug. The
plug must be plugged into an outlet
that is properly installed and
grounded in accordance with all
local codes and ordinances, as well
as the National Electrical Code (NEC)

!

DANGER

NOTICE

!

CAUTION

and, in the United States, the
Occupational Safety and Health Act
(OSHA). 

Improper installa
tion of the

grounding plug is liable to result in
a risk of electric shock. When repair
or replacement of the cord or plug is
required, do not connect the
grounding wire to either flat blade
terminal. The wire with insulation
having an outer surface that is
green,with or without yellow
stripes, is the grounding wire.

Check with a qualified electrician or
serviceman when the grounding
instructions are not completely
understood, or when in doubt as to
whether the product is properly
grounded. Do not modify the plug
provided; if it does not fit the out-
let, have the proper outlet installed
by a qualified electrician.

This product is for use on a nominal
120-V circuit and has a grounding
plug similar to the plug illustrated
in Figure 1. Only connect the prod-
uct to an outlet having the same
configuration as the plug. Do not
use an adapter with this product.

!

WARNING

TEST

RESET

Figure 1 - Grounded three-wire
extension cord

Gauge of Cord

18

16

14

12

10

8

Table 1 – Extension Cords for 120V/15 Amp Unit

Length of Cord (ft.) 25-50

50<100

100<150 150<250 250<400 400-500

Содержание HousePainter EZ5000 Series

Страница 1: ...g on the sprayer Unpacking After unpacking the unit inspect care fully for any damage that may have occurred during transit Make sure to tighten all connection points before putting into service There...

Страница 2: ...l local codes and ordinances as well as the National Electrical Code NEC DANGER NOTICE CAUTION and in the United States the Occupational Safety and Health Act OSHA Improper installa tion of the ground...

Страница 3: ...manufacturer Verify that all containers and col lection systems are grounded to prevent static discharge WARNING Connect to a grounded outlet and use grounded extension cords Do not use a 3 to 2 adapt...

Страница 4: ...d When not in use turn the unit Off see Figure 4 and relieve pressure by triggering the gun in a safe direction Then engage the trig ger lock High pressure spray can inject toxins into the body and ca...

Страница 5: ...urn the unit to the Off posi tion see Figure 6 Be thoroughly familiar with the controls To reduce the risk of injury Always wear appropriate gloves eye protection and a respirator or mask when paintin...

Страница 6: ...sheeting to protect windows Operating Instructions Parts Manual www chpower com 6 light fixtures etc that are not to be painted the same color as the struc ture For best results remove any hinges or f...

Страница 7: ...ubes for 1 gallon paint containers and the 5 gallon set for 5 gallon paint containers Turn the One Touch 7 EZ5000 Series www chpower com Set Up Cont To extend your reach for floors and ceilings consid...

Страница 8: ...see Figure 16 for thin materials such as water seals and polyurethanes The highest pres sure setting see Figure 17 is used for heavier coatings like latex paint The best way to determine the proper s...

Страница 9: ...to activate or release the trigger when your arm is not in motion You will get a build up of paint at any point where the gun is spraying without your arm being in motion Rolling If you use either of...

Страница 10: ...gure 20 Leave the suction and bypass tubes in the bucket of coating Cover the tubes and bucket with a damp towel or if using latex paint pour a very thin layer of water over top of paint Stir water in...

Страница 11: ...ome other cleaning fluid pour enough of the solution into a bucket to come about an inch above the suction filter Do not use a waste bucket Keep the bypass tube in the fluid bucket with the suc tion t...

Страница 12: ...fore each use Before each use Before each use As required As required As required Every 100 gal or more often if required Every 100 gal As required Every 100 gal Every 20 75 gal See parts listing for...

Страница 13: ...r replace gun valve 2 Replace gun valve or replace entire gun 3 Adjust trigger by adjusting nut behind trigger Move nut towards handle if trigger does not move Tighten nut by turn ing towards spray ti...

Страница 14: ...ghten block bolts in an X pat tern or replace block 2 Tighten clamp 3 Remove and replace outlet valve 4 a Tighten hose on outlet valve b Check for damaged thread on connector Replace if nec essary 1 T...

Страница 15: ...dirty worn or defective 3 Dirty or worn inlet or outlet valve 4 Pressure is adjusted too low for material being sprayed 5 Clogged suction filter 6 Clogged gun filter 7 Tip is too large for material b...

Страница 16: ...U S A Ref No Description Part Number Qty 1 1 gallon suction hose kit includes suction hose bypass hose clamps and suction filter EZ500420SV 1 5 gallon suction hose kit includes suction hose bypass hos...

Страница 17: ...LURE OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to y...

Страница 18: ......

Страница 19: ...ttentivement pour tout signe de dommages en transit S assurer de resserrer tous les points de connexion avant de le mettre en marche Il y aura un peu de lubrifiant dans la t te de l appareil cause du...

Страница 20: ...Unis l Occupational Safety and Health Act OSHA DANGER AVIS ATTENTION Une mauvaise installation de la prise mise la terre peut cr er des risques de chocs lectriques S il faut rem placer ou r parer le c...

Страница 21: ...ers toute personne ou ani mal Garder les mains et autres parts du AVERTISSEMENT S curit g n rale suite longe n est pas endommag e En util isant une rallonge s assurer d en utilis er une suffisamment l...

Страница 22: ...e pression peut injecter des toxines dans le corps et provoquer de graves blessures S il y a injection consulter imm di atement un m decin V rifier les tuyaux et les pi ces pour tout signe de dom mage...

Страница 23: ...yau pour tirer ou soulever l quipement AVERTISSEMENT Installation OUTILS N CESSAIRES Tournevis Deux cl s r glables ou deux cl s fourche de 3 4 po ou toute com binaison de ces deux types Rallonge voir...

Страница 24: ...structions de fonctionnement 24 plantes qui pourraient tre endom mag s Retirer ou couvrir les charni res les poign es et autres quincaillerie que l on ne veut pas peindre En peignant l int rieur Pour...

Страница 25: ...vation Lorsqu il n y a plus de bulles tourner la commande touche unique la posi tion de pulv risation voir la figure 15 25 S rie EZ5000 v risation directement au dessus de la t te et donne un autre 2...

Страница 26: ...graduellement la pression et continuer pulv riser des essais apr s chaque ajuste ment jusqu ce qu il n y ait plus de bavures dans le motif de pulv risation voir la figure 18 Utiliser cette m thode po...

Страница 27: ...er l accessoire rouleau sur le pistolet voir la figure 10 Amorcer le pulv risateur tel que d crit la page 8 Lorsqu il n y a plus de bulles visibles dans le tube de d riva tion tourner la commande touc...

Страница 28: ...l eau dans la peinture le lendemain matin Rev tements qui se nettoient l eau Apr s la peinture tourner le bouton de commande touche unique la posi tion d amor age voir la figure 14 Soulever le tube d...

Страница 29: ...er le tube de d rivation dans le seau du fluide avec le tube d aspiration Laisser le fluide cir culer pendant 10 minutes dans la posi tion de nettoyage de pompe voir la fig ure 21 Tourner la commande...

Страница 30: ...vant chaque utilisation Au besoin Au besoin Au besoin Tous les 378 L 100 gallons ou plus souvent au besoin Tous les 378 L 100 gallons Au besoin Tous les 378 L 100 gallons Tous les 20 75 gallons Consul...

Страница 31: ...a commande un r glage plus lev 3 V rifier le niveau d huile Si bas remplir jusqu 1 4 po du haut du bo tier avec de l huile hydraulique 10 W CH AL1702 4 Diluer et ou filtrer tout mat riau 5 Retirer et...

Страница 32: ...r le disjoncteur ou utiliser le disjoncteur de 20 amp res 1 Choisir le bon calibre ou brancher directement dans la prise et utiliser un autre tuyau de pulv risation sup pl mentaire 2 Apporter un centr...

Страница 33: ...on de pulv risation 2 Remplacer le filtre du pis tolet s assurer que le bo ti er du filtre soit libre de d bris 1 Diluer m langer et filtrer tous les mat riaux 2 Nettoyer ou remplacer la buse de pulv...

Страница 34: ...la pompe et r p ter jusqu ce qu elle s amorce Cette proc dure fonctionne seulement si la soupape d aspiration est libre Alimentation sous pression de la pompe 34 Manuel de pi ces et instructions de f...

Страница 35: ...pi ce Qt 1 trousse de tuyau d aspiration de 1 gallon inclut tuyau d aspiration tuyau de d rivation pinces et filtre d aspiration EZ500420SV 1 Trousse de tuyau d aspiration de 5 gallons inclut tuyau d...

Страница 36: ...TOUT D FAUT PANNE OU MAUVAIS FONCTIONNEMENT DU PRODUIT CAMPBELL HAUS FELD Quelques Provinces tats n autorisent pas l exclusion ni la limitation des dom mages fortuits ou indirects La limitation ou exc...

Отзывы: