Operating Instructions and Parts Manual

 

FP260200

www.chpower.com

Definition of terms 

(continued)

Motor Protection - 

If the unit is over 

worked, a thermal limiter will shut unit 
off. If this happens, switch unit to OFF, 
wait 30 minutes to cool, turn ON again 
to resume work.

Operation

lUbrIcatIOn

This is an oilless product and 

DOeS nOt

 

require lubrication to operate.

beFOre FIrSt StartUP  
breaK-In PrOceDUre

Complete this procedure before using 
compressor for the first time. Once 
completed, it is not necessary to repeat.
1.   Turn regulator knob fully clockwise 

(to the right) to open air flow.

2.   Do not attach a hose or any other 

fitting to the compressor.

3.   Turn ON/OFF switch to OFF (

 O 

position.

4.   Plug in power cord.
5.   Turn ON/OFF switch to ON (

 I 

position. Allow compressor to run 
for 5 minutes.

6.   Turn ON/OFF switch to OFF (

 O 

position.

7.   Unplug power cord.

OPeratInG PrOceDUre

1.   Turn switch to OFF (

 O 

) position and 

plug in power cord.

2.   Turn regulator knob 

counterclockwise to close air flow.

3.   Turn switch to ON (

 I 

) position.

4.   Compressor will build to maximum 

pressure and shut off.

5.   With hose attached to outlet of 

compressor, attach tire chuck or 
other tool to open end of hose.

6.   Adjust regulator to proper pressure 

for tool or tire. Operate tool per 
instructions.

As air is depleted from the tank by 
use of a tire chuck, tool, etc., the 
compressor will restart automatically 
at its preset “cut-in” pressure. When 
a tool is being used continuously, 
the compressor will cycle on and off 
automatically.

7.   Turn switch to OFF (

 O 

) position, 

unplug power cord and drain 
tank of air when finished using 
compressor.

User - Maintenance 

Instructions

 

 

 

Disconnect power source 
then release all pressure from 
the system before attempting 
to install, service, relocate or perform 
any maintenance. Service should be 
performed by an authorized service 
representative.

The compressor should be checked 
often for any visible problems and the 
following maintenance procedures 
should be performed each time the 
compressor is used.

aSMe SaFety valve

 

Do not  remove or  

  attempt to adjust 

the safety valve!

Check the safety valve by performing 
the following steps: 
1.   Plug the compressor in and run until 

shut off pressure is reached (see 
Operating Instructions).

2.   Wearing safety glasses, pull the 

ring on the safety valve to release 
pressure from compressor tank. Use 
your other hand to deflect fast-
moving air from being directed 
toward your face.

3.   The safety valve should close 

automatically at approximately 
40-50 psi. If the safety valve does 
not allow air to be released when 
you pull on the ring, or if it does 
not close automatically, it MUST be 
replaced.

DraIn tanK

With compressor shut off and pressure 
released, drain moisture from tank by 
opening drain valve underneath tank.

cleanInG

Turn power OFF and clean dust and dirt 
from pump cover, tank, and air lines.
IMPORTANT: Unit should be located as 
far from spraying area as hose will allow 
to prevent over-spray from clogging air 
filter.

enD OF OPeratIOn/StOraGe

1.   Turn ON / OFF switch to the OFF (

 O 

position.

2.   Unplug power cord from wall outlet 

and wrap around handle area to 
prevent damage when not in use.

3.   Wearing safety glasses drain tank of 

air by pulling the ring on the safety 
valve. Use other hand to deflect 
fast moving air from being directed 
toward your face.

4.   Drain tank of condensation by 

opening drain valve on bottom of 
tank. Tank pressure should be below 
10 psi when draining tank.

5.   Air hose should be disconnected 

from compressor and hung open 
ends down to allow any moisture to 
drain.

6.   Compressor and hose should be 

stored in a cool, dry place.

Figure 6

Figure 5

Содержание FP260200

Страница 1: ...lp recognize this information observe the following symbols Danger indicates an imminently hazardous situation which if not avoided WILL result in death or serious injury Warning indicates a potential...

Страница 2: ...leaning with solvents or toxic chemicals follow the instructions provided by the chemical manufacturer Hose Precautions 20 Inspect hose before use Do not exceed working pressure marked on hose Do not...

Страница 3: ...air pressure released at the hose outlet Turning the regulator knob clockwise to the right will increase air pressure at the outlet Turning the knob counter clockwise to the left will lower air pressu...

Страница 4: ...tempting to install service relocate or perform any maintenance Service should be performed by an authorized service representative The compressor should be checked often for any visible problems and...

Страница 5: ...ion If a leak is detected tighten Or remove fitting and apply pipe tape to threads and reassemble Do not disassemble check valve with air in tank bleed tank first 3 Tank leaks 3 Check entire tank for...

Страница 6: ...ormation Address any correspondence to Model number Campbell Hausfeld Serial number if any Attn Customer Service Part description and number as shown in parts list 100 Production Drive Harrison OH 450...

Страница 7: ...Gauge FP204012AV t 1 24 Regulator and Manifold Assembly FP018800AV t 1 25 ASME Safety Valve V 215100AV 1 26 Check Valve Assembly FP209532AV 1 27 Check Valve 1 28 Poppet 1 29 Spring 1 30 Pressure Switc...

Страница 8: ...abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices are removed or altered this warra...

Страница 9: ...e pour la S CURIT et pour VITER LES PROBL MES D QUIPEMENT Rechercher les symboles suivants pour cette information Danger indique une situation dangereuse imminente qui M NERA la mort ou des blessures...

Страница 10: ...iriger la peinture ou autre mat riel pulv ris vers le compresseur Situer le compresseur aussi loin que possible de l endroit de pulv risation pour r duire l accumulation de surpulv risation sur le com...

Страница 11: ...la terre Dans l venement d un court circuit la mise la terre diminue le risque de secousse lectrique en fournissant un fil d chappement pour le courant lectrique Ce produit est quip avec un cordon qui...

Страница 12: ...7 Quand on a termin d utiliser le compresseur tourner l interrupteur la position OFF ARR T O d brancher le cordon d alimentation et vidanger le r servoir d air Instructions de Maintenance de l Utilis...

Страница 13: ...le clapet Avec de l air dans le r servoir purger le r servoir d abord 3 Le r servoir pr sente de pertes 3 V rifier tout le r servoir avec de l eau savonneuse Le compresseur travaille continuelle ment...

Страница 14: ...suivante Correspondance Num ro du mod le Campbell Hausfeld Num ro de s rie si applicable Attn Customer Service Description de la pi ce et son num ro sur la liste de pi ces 100 Production Drive Harris...

Страница 15: ...lecteur assemblage FP018800AV t 1 25 Soupape de s ret ASME V 215100AV 1 26 Assemblage du clapet FP209532AV 1 27 Clapet 1 28 Champignon 1 29 Ressort 1 30 Pressostat FP018400AV 1 31 R servoir 1 32 Robin...

Страница 16: ...de faire fonctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de s ret Si ces appareils de s ret sont enlev s ou modifi s la garantie...

Страница 17: ...edida de SEGURIDAD y para EVITAR PROBLEMAS CON EL EQUIPO Debe reconocer los siguientes s mbolos Peligro indica una situaci n inminentemente peligrosa que si no se evita dar como resultado la muerte o...

Страница 18: ...lventes o qu micos t xicos siga las instrucciones del fabricante de dichos qu micos Precauciones para las mangueras 20 Revise la manguera antes del uso No exceda la presi n de trabajo indicada en la m...

Страница 19: ...sor El interruptor debe colocarse en la posici n OFF O para conectar o desconectar el cord n el ctrico del tomacorrientes o para cambiar herramientas Interruptor de presi n ubicado internamente Al enc...

Страница 20: ...conecte el cord n el ctrico del tomacorrientes y libere toda la presi n del sistema antes de tratar de instalar darle servicio cambiar de lugar o darle cualquier tipo de mantenimiento El servicio debe...

Страница 21: ...soluci n de agua y jab n Si se detecta una fuga apriete O quite la conexi n y aplique cinta para tuber as a las rocas y vuelva a armar No desarme la v lvula de retenci n Si hay aire en el tanque prim...

Страница 22: ...ente informaci n Puede escribirnos a N mero del modelo Campbell Hausfeld N mero de Serie de haberlo Attn Customer Service Descripci n y n mero del repuesto seg n la lista de repuestos 100 Production D...

Страница 23: ...t 1 24 Regulador y ensamble del distribuidor FP018800AV t 1 25 V lvula de seguridad ASME V 215100AV 1 26 Ensamblaje de V lvula de chequeo FP209532AV 1 27 V lvula de chequeo 1 28 Castillete 1 29 Resor...

Страница 24: ...cluir la desconexi n o modificaci n de los instrumentos de seguridad Si dichos instrumentos de seguridad son desconectados la garant a quedar a cancelada D Los ajustes normales explicados en el los ma...

Отзывы: