Installation (Continued)

 

Improper use of grounding plug   

  can result in a possible risk of 

electrical shock!
 

Do not use a grounding adapter  

  with this product!

2�  If repair or replacement of cord or plug is necessary, do not 

connect grounding wire to either flat blade terminal� The wire 
with insulation having an external surface that is green (with 
or without yellow stripes) is the grounding wire�

 

Never connect green (or green and yellow)  

  wire to a live terminal.

3�  Check with a qualified electrician or serviceman if grounding 

instructions are not completely understood, or if in doubt as 
to whether product is properly grounded� Do not modify plug 
provided; if it will not fit outlet, have proper outlet installed 
by a qualified electrician�

WIRING

1�  Local electrical wiring codes differ from area to area� Source 

wiring, plug and protector must be rated for at least the 
amperage and voltage indicated on motor nameplate, and 
meet all electrical codes for this minimum�

2�  Use a slow blow fuse or a circuit breaker�

Glossary of Terms / Getting to Know your Compressor

Pressure Switch - AUTO/OFF Switch - 
In the AUTO position, the compressor 
shuts off automatically when tank 
pressure reaches the maximum preset 
pressure� In the OFF position, the 
compressor will not operate� This switch 
should be in the OFF position when 
connecting or disconnecting the power 
cord from the electrical outlet or when 
changing air tools�
Regulator - The regulator controls the 
amount of air pressure released at the 
hose outlet�
Discharge Tube - This tube carries 
compressed air from the pump to the 
check valve� This tube becomes very hot 
during use� To avoid the risk of severe 
burns, never touch the discharge tube�
ASME Safety Valve - This valve 
automatically releases air if the tank 
pressure exceeds the preset maximum�
Check Valve - One-way valve that allows 
air to enter the tank, but prevents air 
in the tank from flowing back into the 
compressor pump�
Tank Drain - This valve is located on 
the bottom of the tank� Use this valve 
to drain moisture from the tank daily to 
reduce the risk of corrosion�
Reduce tank pressure below 10 psi by 
pulling the safety valve, then drain 
moisture from tank� Drain daily to avoid 
tank corrosion�

Figure 2

Pump 

Shroud

 

Tank

Pressure 

Switch
Safety 

Valve

Tank Pressure 

Gauge

Outlet Pressure 

Gauge

Universal 

Coupler

Tank  

Drain

Regulator

Содержание CT1001

Страница 1: ...l 1 800 543 6400 for customer assistance Have the serial number model number and parts list with missing parts circled before calling DO NOT RETURN THE PRODUCT TO THE RETAILER Do not operate unit if d...

Страница 2: ...t when you cut sand drill or grind materials such as wood paint metal concrete cement or other masonry This dust often contains chemicals known to cause cancer birth defects or other reproductive harm...

Страница 3: ...the instructions provided by the chemical manufacturer SAVE THESE INSTRUCTIONS DO NOT DISCARD CT1001 Important Safety Information Continued www chpower com 3 Installation The DANGER WARNING CAUTION an...

Страница 4: ...our Compressor Pressure Switch AUTO OFF Switch In the AUTO position the compressor shuts off automatically when tank pressure reaches the maximum preset pressure In the OFF position the compressor wil...

Страница 5: ...r ring has been released or valve is stuck and cannot be actuated by ring it MUST be replaced REGULATOR KNOB 1 This knob controls air pressure to an air operated tool or paint spray gun 2 Turning knob...

Страница 6: ...30 minutes manually reset the thermal overload protector by pushing the button shown in Figure 5 STORAGE 1 When not in use store hose and compressor in a cool dry place 2 Drain tank of moisture 3 Disc...

Страница 7: ...ve bearing on eccentric or motor shaft 3 Replace 4 Cylinder or piston ring is worn or scored 4 Replace or repair as necessary 5 Loose bolts tank not level 5 Tighten bolts shim tank to level position T...

Страница 8: ...ther contaminants c Cosmetic defects that do not interfere with compressor functionality d Rusted tanks including but not limited to rust due to improper drainage or corrosive environments e The follo...

Страница 9: ...num ro de mod le et liste de parties avec les parties manquantes encercl es avant d appeler NE PAS RENVOYER LE PRODUIT AU MARCHAND Ne pas utiliser un mod le qui a t endommag pendant le transport la m...

Страница 10: ...ment ou autre ma onnerie Cette poussi re contient souvent des produits chimiques reconnus pour causer le cancer les d formations cong nitales G N RALIT S SUR LA S CURIT Lire attentivement tous manuels...

Страница 11: ...i re et le d bris qui peut tre dangereux L cher l air lentement en purgeant l humidit ou pendant la d pressurisation du syst me de compresseur CT1001 Importantes Instructions De S curit Suite F3 Les s...

Страница 12: ...s la position AUTO le compresseur se coupe automatiquement quand la pression du r servoir arrive la pression maximale r gl e d avance Dans la position OFF le compresseur ne fonctionnera pas Cet interr...

Страница 13: ...R COMPRIM L humidit dans l air comprim forme des goutelettes en arrivant de la pompe du compresseur Si l humidit est lev e ou si le compresseur est utilis continuellement cette humidit s accumulera da...

Страница 14: ...eur de surchauffe thermique en enfon ant le bouton indiqu dans la Figure 5 ENTREPOSAGE 1 Si hors d usage entreposer le tuyau et le compresseur dans un endroit frais et sec 2 Purger l humidit du r serv...

Страница 15: ...ou r parer si n cessaire 3 Palier d fectueux sur l excentrique ou sur l arbre du moteur 3 Remplacer 4 Cylindre ou segment de piston us ou ray 4 Remplacer ou r parer si n cessaire 5 Boulons d gag s r s...

Страница 16: ...mais sans s y limiter la rouille caus e par la vidange incorrecte ou par un environnement corrosif e Les composants suivants sont consid r s comme des articles sujets l usure normale et ne sont pas co...

Страница 17: ...e serie el n mero del modelo y la lista de partes con las partes que faltan marcadas con un c rculo antes de llamar NO DEVUELVA EL PRODUCTO AL MINORISTA No debe utilizar la unidad si se ha da ado dura...

Страница 18: ...o madera pintura metal hormig n cemento u otro tipo de mamposter a se puede producir polvo Con frecuencia este polvo contiene productos qu micos que se conocen como causantes de c ncer defectos cong n...

Страница 19: ...lventes o qu micos t xicos siga las instrucciones del fabricante de dichos qu micos GUARDE ESTAS INSTRUCCIONES NO LAS DESECHE Los s mbolos de PELIGRO ADVERTENCIA PRECAUCI N y AVISO y las instrucciones...

Страница 20: ...camente cuando la presi n del tanque alcanza el nivel m ximo fijado en la f brica En la posici n OFF el compresor no funcionar El presostato debe colocarse en OFF para conectar o desconectar el cord n...

Страница 21: ...nque para verificar que el sistema est funcionando adecuadamente Funcionamiento HUMEDAD EN EL AIRE COMPRIMIDO La humedad que se acumula en el aire comprimido se convierte en gotas a medida que sale de...

Страница 22: ...esionando el bot n que se muestra en la Figura 5 ALMACENAMIENTO 1 Mientras no lo est usando debe almacenar el compresor y las mangueras en un sitio seco y fr o 2 Debe drenar el tanque 3 Debe desconect...

Страница 23: ...del pist n est desgastado o rayado 4 Reempl celo o rep relo seg n sea necesario 5 Pernos flojos tanque desnivelado 5 Apriete los pernos nivele el tanque con unas almohadillas La presi n del tanque ba...

Страница 24: ...al drenaje inadecuado u agentes corrosivos en el ambiente e Las siguientes piezas se consideran art culos sujetos a desgaste normal y no son cubiertas despu s del primer a o de propiedad Motor el ctri...

Отзывы: