An ASME code safety relief valve with a   

  setting no higher than the Maximum 

Allowable Working Pressure (MAWP) of the tank MUST be 

installed in the air lines or in the tank for this compressor. 

The ASME safety valve must have sufficient flow and pressure 

ratings to protect the pressurized components from bursting. 

The flow rating can be found in the parts manual. The safety 

valve in the intercooler does not provide system protection. 

  Never attempt to adjust ASME safety valve� Keep safety valve 

free from paint and other accumulations�

 

Never attempt to repair or  

  modify a tank! Welding, drilling 

or any other modification will weaken the tank 

resulting in damage from rupture or explosion. 

Always replace worn, cracked or damaged tanks.

 

  Drain liquid from tank daily.

  Tanks rust from moisture build-up, which weakens the tank� 

Make sure to drain tank regularly and inspect periodically for 
unsafe conditions such as rust formation and corrosion�

  Fast moving air will stir up dust and debris which may be 

harmful� Release air slowly when draining moisture or 
depressurizing the compressor system�

SPRAYING PRECAUTIONS

 

Do not spray flammable  

  materials in vicinity of open 

flame or near ignition sources including the 

compressor unit.

  Do not smoke when spraying paint, insecticides, or other 

flammable substances�

  Use a face mask/respirator when spraying and 

spray in a well ventilated area to prevent health 
and fire hazards�

  Do not direct paint or other sprayed material 

at the compressor� Locate compressor as far away from 
the spraying area as possible to minimize overspray 
accumulation on the compressor�

  When spraying or cleaning with solvents or toxic 

chemicals, follow the instructions provided by the chemical 
manufacturer�

SAVE THESE INSTRUCTIONS 

DO NOT DISCARD

CT1001

Important Safety Information (Continued)

www.chpower.com

3

Installation

The DANGERWARNINGCAUTION, and NOTICE notifications and instructions in this manual cannot cover all possible 
conditions and situations that may occur� It must be understood by the operator that caution is a factor which cannot be 
built into this product, but must be supplied by the operator�

LOCATION

The tank must sit level or slope slightly towards the drain valve 
to allow the tank to drain properly�
It is extremely important to install the compressor in a clean, 
well ventilated area where the surrounding air temperature will 
not be more than 100°F�
A minimum clearance of 4 inches between the compressor and a 
wall is required because objects could obstruct air flow�
 

Do not locate the compressor air inlet near 

  steam, paint spray, sandblast areas or any 

other source of contamination. This debris will damage the 

motor.

ELECTRICAL INSTALLATION

 

All wiring and electrical connections   

  should be performed by a qualified 

electrician. Installation must be in accordance with local  

codes and national electrical codes.

GROUNDING INSTRUCTIONS

1�  This product is for use on a nominal 120 volt circuit and 

has a grounding plug that looks like the plug illustrated in 
Figure 1� Make sure the product is connected to an outlet 
having the same configuration as the plug� This product 
must be grounded� In the event of an electrical short circuit, 
grounding reduces risk of electrical shock by providing an 
escape wire for electric current� This product is equipped 
with a cord having a grounding wire with an appropriate 
grounding plug� Cord must be plugged into an outlet that is 
properly installed and grounded in accordance with all local 
codes and ordinances�

Figure 1

Grounded 

Pin

Grounded 

Outlet

Содержание CT1001

Страница 1: ...l 1 800 543 6400 for customer assistance Have the serial number model number and parts list with missing parts circled before calling DO NOT RETURN THE PRODUCT TO THE RETAILER Do not operate unit if d...

Страница 2: ...t when you cut sand drill or grind materials such as wood paint metal concrete cement or other masonry This dust often contains chemicals known to cause cancer birth defects or other reproductive harm...

Страница 3: ...the instructions provided by the chemical manufacturer SAVE THESE INSTRUCTIONS DO NOT DISCARD CT1001 Important Safety Information Continued www chpower com 3 Installation The DANGER WARNING CAUTION an...

Страница 4: ...our Compressor Pressure Switch AUTO OFF Switch In the AUTO position the compressor shuts off automatically when tank pressure reaches the maximum preset pressure In the OFF position the compressor wil...

Страница 5: ...r ring has been released or valve is stuck and cannot be actuated by ring it MUST be replaced REGULATOR KNOB 1 This knob controls air pressure to an air operated tool or paint spray gun 2 Turning knob...

Страница 6: ...30 minutes manually reset the thermal overload protector by pushing the button shown in Figure 5 STORAGE 1 When not in use store hose and compressor in a cool dry place 2 Drain tank of moisture 3 Disc...

Страница 7: ...ve bearing on eccentric or motor shaft 3 Replace 4 Cylinder or piston ring is worn or scored 4 Replace or repair as necessary 5 Loose bolts tank not level 5 Tighten bolts shim tank to level position T...

Страница 8: ...ther contaminants c Cosmetic defects that do not interfere with compressor functionality d Rusted tanks including but not limited to rust due to improper drainage or corrosive environments e The follo...

Страница 9: ...num ro de mod le et liste de parties avec les parties manquantes encercl es avant d appeler NE PAS RENVOYER LE PRODUIT AU MARCHAND Ne pas utiliser un mod le qui a t endommag pendant le transport la m...

Страница 10: ...ment ou autre ma onnerie Cette poussi re contient souvent des produits chimiques reconnus pour causer le cancer les d formations cong nitales G N RALIT S SUR LA S CURIT Lire attentivement tous manuels...

Страница 11: ...i re et le d bris qui peut tre dangereux L cher l air lentement en purgeant l humidit ou pendant la d pressurisation du syst me de compresseur CT1001 Importantes Instructions De S curit Suite F3 Les s...

Страница 12: ...s la position AUTO le compresseur se coupe automatiquement quand la pression du r servoir arrive la pression maximale r gl e d avance Dans la position OFF le compresseur ne fonctionnera pas Cet interr...

Страница 13: ...R COMPRIM L humidit dans l air comprim forme des goutelettes en arrivant de la pompe du compresseur Si l humidit est lev e ou si le compresseur est utilis continuellement cette humidit s accumulera da...

Страница 14: ...eur de surchauffe thermique en enfon ant le bouton indiqu dans la Figure 5 ENTREPOSAGE 1 Si hors d usage entreposer le tuyau et le compresseur dans un endroit frais et sec 2 Purger l humidit du r serv...

Страница 15: ...ou r parer si n cessaire 3 Palier d fectueux sur l excentrique ou sur l arbre du moteur 3 Remplacer 4 Cylindre ou segment de piston us ou ray 4 Remplacer ou r parer si n cessaire 5 Boulons d gag s r s...

Страница 16: ...mais sans s y limiter la rouille caus e par la vidange incorrecte ou par un environnement corrosif e Les composants suivants sont consid r s comme des articles sujets l usure normale et ne sont pas co...

Страница 17: ...e serie el n mero del modelo y la lista de partes con las partes que faltan marcadas con un c rculo antes de llamar NO DEVUELVA EL PRODUCTO AL MINORISTA No debe utilizar la unidad si se ha da ado dura...

Страница 18: ...o madera pintura metal hormig n cemento u otro tipo de mamposter a se puede producir polvo Con frecuencia este polvo contiene productos qu micos que se conocen como causantes de c ncer defectos cong n...

Страница 19: ...lventes o qu micos t xicos siga las instrucciones del fabricante de dichos qu micos GUARDE ESTAS INSTRUCCIONES NO LAS DESECHE Los s mbolos de PELIGRO ADVERTENCIA PRECAUCI N y AVISO y las instrucciones...

Страница 20: ...camente cuando la presi n del tanque alcanza el nivel m ximo fijado en la f brica En la posici n OFF el compresor no funcionar El presostato debe colocarse en OFF para conectar o desconectar el cord n...

Страница 21: ...nque para verificar que el sistema est funcionando adecuadamente Funcionamiento HUMEDAD EN EL AIRE COMPRIMIDO La humedad que se acumula en el aire comprimido se convierte en gotas a medida que sale de...

Страница 22: ...esionando el bot n que se muestra en la Figura 5 ALMACENAMIENTO 1 Mientras no lo est usando debe almacenar el compresor y las mangueras en un sitio seco y fr o 2 Debe drenar el tanque 3 Debe desconect...

Страница 23: ...del pist n est desgastado o rayado 4 Reempl celo o rep relo seg n sea necesario 5 Pernos flojos tanque desnivelado 5 Apriete los pernos nivele el tanque con unas almohadillas La presi n del tanque ba...

Страница 24: ...al drenaje inadecuado u agentes corrosivos en el ambiente e Las siguientes piezas se consideran art culos sujetos a desgaste normal y no son cubiertas despu s del primer a o de propiedad Motor el ctri...

Отзывы: