Use and maintenance manual
–
Translation of
original Instruction Rev.: 00, Data 26/11/2018
Pag. 19
WARNING!
•
Use the unit only for the purposes described in par. "Description of the Product". Any other use may cause
injuries.
•
The backpack (3) shall be positioned in such a way that the 90% of its weight is supported by the operator’s
waist instead of by his back.
•
The braces shall be used to improve the weight balancing (10%).
5.2
Display
After quickly pressing the ON/OFF button (11) on the display (9), the charge level will be visible for about 5 seconds with
the following modes:
• 4 led bars – 80/100% charge level
• 3 led bars – 60/80% charge level
• 2 led bars – 40/60% charge level
• 1 led bar – 20/40% charge level
• 1 flashing led light – charge level is lower than 20%
• All flashing LED lights with repetition each second = Error status.
If any undervoltage is detected, it persists even if the battery is switched off and then on again, until it reaches at least the
20% of its status of charge (SoC).
WARNING!
If the problem cannot be solved, take the battery to an Authorized Service Point.
5.2.1
ON/OFF battery led light
When the button is pressed while switching off the battery, the timed lit-up led bars quantity will decrease up to zero.
When the last LED bar is off, the battery switches off by releasing the button.
5.2.2
ON/OFF power supply management
• When the battery is off, it is switched on by pressing the button. The charge level can be seen for 5 seconds.
• When the battery is off, it is switched on by connecting it to the charger. The charge level can be seen on as long as
the charger is connected.
• If the consumption is less than 200 mA, the self-switching-OFF timer is activated. Timing depends on the battery pack
status of charge (SoC).
• The operator can switch off the battery by keeping the button pressed for at least 5 seconds.
• The battery switches off automatically, when the charger is disconnected or when charge is complete
• While the battery is charging, it cannot be switched off.
5.3
Battery re-charging
For the recharge operations please read the manual of the battery-charger.
5.4
Troubleshooting
WARNING!
All the following maintenance operations shall be carried out by a mechanical maintenance technician.
FAULT
CAUSE
RIMEDY
The battery does not turn on
Flat battery
Re-charge the battery
The battery is off
Auto switch-OFF entered
Turn the battery
ON
(4) by means of the switch.
The battery display is flashing Error detected
Switch the battery off and on again to reset the error.
Содержание Line 58
Страница 4: ...Manuale Uso e Manutenzione Istruzioni Originali Rev 00 Data 26 11 2018 Pag 3...
Страница 50: ...00 26 11 2018 49 CAMPAGNOLA S r l CAMPAGNOLA S r l...
Страница 53: ...52 00 26 11 2018 2 1 2003 10 2002 44 81 2008 2 1 1 1 2004 108 2 2 2 3 2 2 60 C 3 6 2...
Страница 54: ...00 26 11 2018 53 Warranty 2 4 CAMPAGNOLA S r l 3 1 CE 3 2 2 3 1 2 3 3 3 3 4...
Страница 57: ...56 00 26 11 2018 6 1 On Off 4 6 1 1 2 180 2 180 6 1 1 2 6 2 7 1 a b...
Страница 58: ...00 26 11 2018 57 7 2 2002 95 2002 96 2003 108...
Страница 95: ...94 00 26 11 2018 CAMPAGNOLA S r l...
Страница 98: ...00 26 11 2018 97 2 1 2 2003 10 EC 2002 44 EC 81 2008 1 1 2 1 2004 108 EC 2 2 3 2 2 2 60 3 6 2 Garanzia Warranty...
Страница 99: ...98 00 26 11 2018 4 2 CAMPAGNOLA S r l 3 1 3 2 3 2 3 1 2 A 3 3 3 4 3...
Страница 101: ...100 00 26 11 2018 3 90 10 2 5 11 9 5 4 80 100 3 60 80 40 60 1 20 40 1 20 1 20 SoC 1 2 5 2 2 5 5 200 5 3 5 4 5 On Off 4...
Страница 102: ...00 26 11 2018 101 6 1 6 On Off 4 1 1 6 2 180 2 180 1 1 6 2 2 6 7 1 7 2 7 2002 95 CE 2002 96 CE 2003 108 CE...
Страница 103: ...102 00 26 11 2018...