Operation and maintenance instructions
Series PME CANopen proportional pressure
regulator
5000054187
Ver. 01
41
0x4210
Device temperature error
0x5530
Memory error
0x5220
Micro error
0x8302
Pressure error
0x5410
Driver error
11.3.2.5.
1005h COB-ID sync
This object contains the configuration of the COB-ID of the synchronization message (SYNC), it
indicates whether the device generates the message or not.
BIT
VALUE
DESCRIPTION
31(MSB)
X
Not used
30
0
1
The device does not generate the SYNC message
The device generates the SYNC message
29
0
1
11-bit CAN-ID
29-bit CAN-ID
28-0
X
Extended address 29 bit
11-0
X
Standard address 11 bit
11.3.2.6.
1006h Communication cycle period
This object contains the period in milliseconds of the cyclic communication of SYNC messages, when
its value is null the device does not send synchronism messages.
11.3.2.7.
1007h Synchronous window length
This object the time from the synchronism message within which these PDOs must arrive to be valid.
If the value is set to zero, the synchronization is disabled.
11.3.2.8.
1008h Manufacturer device name
This object contains the device name given by the manufacturer.
11.3.2.9.
1009h Manufacturer hardware version
This object contains the hardware version of the device.
11.3.2.10.
100Ah Manufacturer software version
This object contains the firmware version of the device.