11.3.2.
CiA 301 profile objects description
11.3.2.1.
1000h Device type
This object contains information about the device type and its functionality. It consists of two 16-bit
fields: the first one describes the profile used and the second one contains specific additional
information.
11.3.2.2.
1001h Error register
This object contains the internal device error mapping, is a mandatory object for all devices and is
included in the emergency objects. The defined values are defined in the following table.
BIT
OPZIONALE
DESCRIZIONE
0
Mandatory
Generic error
1
Optional
Current
2
Optional
Voltage
3
Optional
Temperature
4
Optional
Communication error
5
Optional
Specific of profile
6
Optional
Reserved
7
Optional
Reserved
11.3.2.3.
1002h Manufacturer status register
This object contains the status of the device, it is specific to the manufacturer
11.3.2.4.
1003h Pre-defined error field
This object contains errors that have occurred on the device and that have been reported by the
emergency message. Doing so, it provides a history.
Sub-index 0 contains the number of errors that are currently saved from sub-index 1 to sub-index
8. When there are no errors, it contains the value zero. Each new error is saved at index 1 and the
old ones are moved to the major indices.
Writing zero on sub-index 0 involves deleting the history, resetting all saved errors.
Each error consists of a 16-bit field that contains the error code, defined by CANopen.
MANUFACTURER
INFORMATION
ERROR TYPE
0x0000
No error
0x2320
Overcurrent coil error
0x3120
Master power supply too low error