28
Repair hints
Operation with closed fire box in accordance with EN 13229
Lina GT
7363
Lina
7345 s/h
7351 s/h
7357 s/h
7363 s/h
Lina
8745 h
8751 h
8757 h
Lina
8770 h
Lina
10045 h
10051 h
10057 h
Lina
12045 h
12051 h
12057 h
Lina TV
4545 s/h
4551 s/h
4557 s/h
4580 h
Nominal heat output
kW
6
9
10
19
10
10
7
Thermal output range
kW
4.4–6.3
3.2–10.9
4.6–10.1
8.0–19.2
3.2–10.9
4.9–10.6
3.4–7.8
Room heat output
kW
6
9
10
19
10
10
7
Heat distribution:
through the viewing window
%
25
35
35
35
35
40
50
Heat distribution:
convective output
%
75
65
65
65
65
60
50
Suitable for multiple flue connections to the chimney
Flue gas connector
Ø in mm
180
200
200
200
200
200
180
Combustion air connector
Ø in mm
125
150
150
150
150
150
125
SMR combustion control
recommended free cross-section
1
Supply air (cm
2
)
1080
1410
1560
2970
1560
1440
840
Recirculation air (cm
2
)
900
1170
1300
2470
1300
1200
700
Combustion air requirement
m³/h
24
36
40
76
40
40
28
Recommended quantity of wood, approx.
kg
2.5
4.0
4.5
5.5
5.0
5.0
3.0
Recommended quantity of wood with NHK, approx.
kg
---
5.5
5.5
---
9.0
---
---
Recommended quantity of wood with heat storage
system, approx.
kg
4.5
6.0
---
---
---
---
5,5
Recommended length of logs
cm
33
33
33
33
33
33
33
Fuel conversion
kg/h
1.8
4.7
---
---
---
---
5.1
Minimum distance to the fire box
(in accordance with TR OL 2006, version 2010)
mm
800
800
800
800
800
800
800
Minimum distance to the insulation
(in accordance with TR OL 2006, version 2010)
mm
60
90
100
100
100
100
70
Insulation thickness
(with a wall that does not need to
be protected) (based on SILCA® 250KM)
mm
60
60
60
60
60
60
60
Weight
kg
230
230-290
280-320
350
310-350
340-400
190-250
Fuel
Type
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Triple v
alues
with nominal
heat output
Flue gas mass flow
g/s
6.2
9.1
8.9
17.8
10.1
7.9
7.5
Flue gas temperature
°C
214
320
320
263
320
365
330
Required delivery pressure
Pa
12
12
12
12
12
12
12
Triple v
alues
for
connecting
cer
amic flues
(w
ood used as
fuel)
Firing power
kW
15
19.8
---
---
---
---
18.2
Flue gas mass flow
g/s
14.5
16.7
---
---
---
---
14.7
Flue gas temperature
upstream of the connecting surface
°C
418
345
---
---
---
---
337
Required delivery pressure at the flue
gas connector
Pa
15
15
---
---
---
---
15
Combustion air requirement
m³/h
56
59.6
---
---
---
---
63,9
Recommended flue length
2
m
---
3.5
3.5
---
3.5
3.5
3.5
Emission v
alues
W
ood fuel
CO
- based on 13 % O₂
mg/Nm³
< 1250
< 1250
< 1250
< 1250
< 1250
< 1250
> 1250
Dust
- based on 13 % O₂
mg/Nm³
< 40
< 40
< 40
< 40
< 40
< 40
< 40
Efficiency
%
> 80
> 78
> 78
> 78
> 78
> 80
> 78
Minimum heat-emitting surface
3
(based on closed design)
m²
2.7
4.0
4.4
7.6
4.4
4.1
2.4
Ecodesign Regulation in accordance with (EU) 2015/1185
Energy efficiency class in accordance with (EU) 2015/1186
Energy efficiency index (EEI)
112.7
103.4
103.2
103.2
103.4
106.6
103.7
Declaration of Performance
No.
LE1260504-1
LE29061074-2
LE29102338
LE848363-1
LE29061074-3
LE29102334
LE29061106
possible connected equipmen
t
Top mounted heat exchanger
---
---
---
---
---
Hot air top-mounted element
---
---
---
---
Heat exchanger
---
---
---
---
Efficiency with connected equipment
%
---
> 80
> 80
---
> 80
---
---
Hot water top-mounted element (HWAR R)
---
---
---
4
s = hinged door, h = guillotine door, TV = tunnel version
The specified waterside output was determined under test conditions. The achievable output can vary
depending on the flue liner, quantity of wood and pump assembly used.
1
The calculation was based on “TR OL 2006, edition 2010 – Table 17: Free cross-section in cm² for grille or
opening tile based on the thermal output for air heating” with the preferred air velocity of 0.75 m/s. Supply air
grille 240 cm2 / kW, recirculation air grille 200 cm² / kW.
2
The information regarding flue lengths is a recommendation and based on the
calculation in accordance with TR OL 2022 chapter 15. The calculation is based on a
medium-heavy design and a flue ratio of 360 cm².
4
With the exception of height 80 cm
3
Average value based on the storage time. Depending on the material properties
and the construction thickness.
Mean specific heat distribution = approx. 500 W / m²