Camina & Schmid Lina 4545 s Скачать руководство пользователя страница 14

14

Fuels

2.3 

Weight and dimensions

The weight and dimensions of the product vary depending 

on the type and model. The serial plate includes important 
information – such as the serial number – for identifying the 
appliance.

2.4 

Function

The fireplace inserts are room air-dependent combustion 

systems and fulfil the following function:

 

 Individual room heating (stove) by warm air and radiation 

heat, produced by the combustion cycle in the firebox.

Fig. 10:  Heating circuit, diagram

2.4.1 

Fire box

The firebox is used to burn wood fuels. The oxygen needed 

for combustion is supplied through openings in the lower 
part of the appliance. The heating gases produced by the 
combustion process are discharged through a flue gas 
connector. For greater efficiency, additional equipment can 
be connected downstream of the fireplace insert. Depending 
on the design, these can lead to higher convective output, 
heat storage or hot water heating. The exhaust gases are 
then transported to the chimney via the connection pipe. 

The wood ash produced remains in the firebox without ash 

collector, and with appliances with ash box it is collected 
under the firebox.

2.5 

Heating technology and environment

Wood is an energy source that is constantly regenerated and 

is CO2-neutral in terms of the environment and in the natural 
cycle.

Fig. 11:  Environmental and wood cycle

The fireplace inserts are technically designed for optimum 

combustion with low CO2 emissions and achieve a high 
energy efficiency class. 

The prerequisite for optimum use of this heating technology 

is the professional design and installation of the appliance by 
the specialist company and regular care and maintenance of 
the fireplace.

The selection of fuels used also has a positive impact on 

combustion efficiency in the fireplace.

3. 

Fuels

PROHIBITED! Never use waste materials as fuel!

Only use the fuels approved for the appliance!

The fireplace inserts are solely designed for logs 

and wood briquettes. Never use coal, peat, wood 
pellets or other fuels!

3.1 

Prohibited fuels

Newly felled, impregnated, painted, glued or coated wood, 
chipboard, shavings and sawdust, bark and chipboard waste, 
cardboard, waste paper briquettes, plastics and household 
waste are all prohibited fuels! 

Содержание Lina 4545 s

Страница 1: ...Fireplace insert OPERATING INSTRUCTIONS LINA 45 120 LINA TV 45 120...

Страница 2: ...na 5557 h Lina 5580 h Lina 6745 h Lina 6751 h Lina 6757 h Lina 6780 h Lina 7345 s Lina 7351 s Lina 7357 s Lina 7363 s All rights reserved The reprinting reproduction and dissemination either in whole...

Страница 3: ...551 s s Lina TV 4557 s s Lina TV 5545 s s Lina TV 5551 s s Lina TV 5557 s s Lina 7351 h Kristall Lina 7363 h Kristall Lina 8745 h Lina 8751 h Lina 8757 h Lina 8770 h Lina 10045 h Lina 10051 h Lina 100...

Страница 4: ...llation instructions heat protective glove tensioning key depending on model front fireplace glass cleaner stove paint long adjustable feet depending on model Lina TV 6745 h s Lina TV 6751 h s Lina TV...

Страница 5: ...s 15 3 3 1 Recommended residual moisture level 15 3 3 2 Heating behaviour of wood 15 3 3 3 Calorific value of the wood 16 3 3 4 Correct drying and storage 16 3 3 5 Drying time 16 3 4 Wood briquettes 1...

Страница 6: ...gulations These operating instructions are intended to help you use this heating technology safely and properly Compliance with these operating instructions will ensure your safety and is the prerequi...

Страница 7: ...the safe use of this product and indicates possible dangers It provides information on how dangers can be avoided 1 4 Important information Information indicated by the i symbol provides useful infor...

Страница 8: ...n accordance with EU 305 2011 From your dealer importer or E mail info camina schmid de Website www camina schmid de leistungserklaerungen D C Fig 1 Serial plate No Type A CE marking as per EC No 765...

Страница 9: ...lace inserts are not in operation 1 8 5 Multiple flue connections Refer to chapter 12 Technical data regarding the suitability of the fireplace inserts if more than one fireplace is connected to the s...

Страница 10: ...ransition times e g autumn or spring or in bad weather e g fog strong wind etc Keep the door closed when the fireplace is in operation Make sure that doors with self closing function always need to be...

Страница 11: ...cian chimney sweep and check the chimney for damage 2 Determine the cause of the chimney fire with the technician chimney sweep and rectify it 1 11 Fire protection Comply with all state building regul...

Страница 12: ...m A B Fireplace insert Fig 4 Protection of combustible components in the radiation range in front of the fire box opening Lina Lina TV Description A Ventilated radiation protection B Parts made of com...

Страница 13: ...Rear hinged door Further information on the appliance types can be found in chapter 12 Technical data Example of construction other types are similar 2 2 Installation of Lina Lina TV guillotine door C...

Страница 14: ...od ash produced remains in the firebox without ash collector and with appliances with ash box it is collected under the firebox 2 5 Heating technology and environment Wood is an energy source that is...

Страница 15: ...mperature as quickly as possible to over 500 C Only then is the carbon in the wood converted into carbon dioxide rather than carbon monoxide a high combustion chamber temperature is also necessary for...

Страница 16: ...especially during the colder and wetter months of the year 3 3 5 Drying time A minimum of one year is a guideline time for drying softwood e g coniferous wood birch and a minimum of two years for har...

Страница 17: ...start up report at the end of these operating instructions The technician needs to hand over to the operator all the technical documents on the appliance and all accessory parts for the safe operatio...

Страница 18: ...ontrolled ventilation of no more than 4 Pa of under draught towards the outside at the location of the fireplace insert When simultaneously operating extraction systems e g ventilation systems extract...

Страница 19: ...ombustion air is guaranteed Refer to chapter 7 1 3 Removing ash for the procedure 5 3 2 Recommended wood arrangement The cross section of the wood logs and arrangement of the wood in the firebox is cr...

Страница 20: ...minute so that excess oxygen flows in and prevents the ceramic glass window from fogging up when it is heated up Refer to chapter 12 Technical data for the recommended loading capacity 5 5 Phases of...

Страница 21: ...this position when the fireplace insert is not in use 5 6 Combustion on ash grate The wood rests on the ash grate with appliances with an ash grate The ash is collected in a ash box underneath which c...

Страница 22: ...ith the instructions for use Service Box The cleaning intervals depend on the operating time heating habits and the quality of the fuel Adjust the frequency of cleaning to these conditions Do not imme...

Страница 23: ...e top of the door by swivelling them This secures the door and it can no longer be raised The locking tongues B C are located under the cover of the guillotine door A B A Fig 27 Locking tongue closed...

Страница 24: ...king properly again B A Fig 32 Right locking tongue open Components A Locking tongue on left B Locking tongue on right 7 1 5 Rear tilting door in cleaning position Lina TV Kristall model 1 Open lock b...

Страница 25: ...8 Combustion air setting Check whether the combustion air lever is in the fully open position 5 5 Combustion air from the room Open the window and switch off any extraction system 1 8 5 5 1 External c...

Страница 26: ...ll breaks in operation and longer pauses check the heating and exhaust paths specifically the chimney for blockages and remove blockages before starting up the fireplace again Check the entire firepla...

Страница 27: ...sure Pa 12 12 12 12 12 12 12 Triple values for connecting ceramic flues wood used as fuel Firing power kW 13 2 18 2 18 2 18 2 Flue gas mass flow g s 11 9 14 7 15 1 16 3 Flue gas temperature upstream o...

Страница 28: ...d delivery pressure Pa 12 12 12 12 12 12 12 Triple values for connecting ceramic flues wood used as fuel Firing power kW 15 19 8 18 2 Flue gas mass flow g s 14 5 16 7 14 7 Flue gas temperature upstrea...

Страница 29: ...livery pressure Pa 12 12 12 12 12 12 Triple values for connecting ceramic flues wood used as fuel Firing power kW 18 2 18 2 19 8 Flue gas mass flow g s 15 1 29 6 16 7 Flue gas temperature upstream of...

Страница 30: ...ik GmbH Co KG Supplier s model ID Lina 55 s h Lina TV 55 s s h s Energy efficiency class A Direct heat output kW 7 0 Indirect heat output kW Energy efficiency index EEI 109 0 Fuel energy efficiency at...

Страница 31: ...s Lina 8770 h Energy efficiency class A A Direct heat output kW 10 0 19 0 Indirect heat output kW Energy efficiency index EEI 103 2 103 2 Fuel energy efficiency at nominal heat output 78 1 78 1 Infor...

Страница 32: ...E F G 2015 1186 6 0 kW ENERGIA ENERGIJA ENERGY ENERGIE ENERGI A A A A A A 80 A 60 A 40 A 20 Lina GT 7363 h A A A B C D E F G 2015 1186 9 0 kW ENERGIA ENERGIJA ENERGY ENERGIE ENERGI A A A A A A 80 A 6...

Страница 33: ...5 0 75 0 40 120 1500 200 103 3 Lina 55 RRF 29 10 2333 7 0 kW 65 0 75 0 40 120 1500 200 109 Lina 67 RRF 29 15 4500 1 9 0 kW 65 0 75 0 40 120 1500 200 107 5 Lina 73 RRF 29 06 1074 9 0 kW 65 0 75 0 40 12...

Страница 34: ...f the complaint by the specialist company is possible with prior written agreement and clarification of cost with the manufacturer Warranty period and limitation period Depending on the product the wa...

Страница 35: ...unless they are directly related to damage under warranty Reimbursement for indirect or direct consequential damag es Reimbursement of indirect or direct consequential damages e g air freight disposal...

Страница 36: ...36...

Страница 37: ...r invoice and this warranty certificate for our warranty to come into force Please note our General Terms and Conditions of Sale Please also note that this certificate must carry a registration number...

Страница 38: ...rage stone systems BA_Lina_LinaTV_45_120_V9_2022_07_78 4668 3101_EN Camina Schmid 2022 07 100 Natural stone systems Hydronic technology Gas fireplace inserts Our product range Camina Schmid Feuerdesig...

Страница 39: ...le wall multi wall outer wall stainless steel Combustion air supply Operating mode room air composite external combustion air Combustion air conduit Diameter mm Extended length m Bend Ventilation syst...

Страница 40: ...rmal discharge safety device fitted easily accessible poss inspection opening Expansion tank Appliance protected by its own expansion tank Cap valve fitted System pressure checked and adjusted bar Pip...

Отзывы: