12
Safety
1.11.2
Parts made of combustible materials
1.11.2.1 Within the radiation range
Adhere to the following safety distances with regard to
parts made of combustible materials or combustible parts,
including fitted furniture, installed close to fireplaces:
There needs to be a spacing of at least 800 mm from the
front/top and sides of the fire box opening to combustible
components.
A distance of 400 mm is enough if a radiation shield is fitted,
vented on both sides. The distance of the ventilated radiation
protection needs to be at least 20 mm.
min. 800 mm
min. 400 mm
Fireplace
min. 20 mm
A
B
Fireplace insert
Fig. 4: Protection of combustible components in the
radiation range in front of the fire box opening, Lina,
Lina TV
Description
:
A = Ventilated radiation protection
B = Parts made of combustible materials, furniture, fabrics
1.11.2.2 Outside the radiation range
Ensure the following safety distances with regard to parts
made of combustible materials or combustible parts,
including fitted furniture:
There needs to be a minimum distance of 50 mm from the
free outside surfaces of the surrounding facing the location
of the fireplace to combustible materials or combustible
components and fitted furniture.
min. 50 mm
Fireplace
A
Fireplace insert
Fig. 5: Protection and distances with heated surfaces, Lina,
Lina TV
Description
:
A = Parts made of combustible materials, furniture, fabrics