11
Safety
1.10
Behaviour in the event of an
emergency
1.10.1
In the event of a fire
Correct behaviour in the event of a fire:
1.
Never put yourself or other people’s lives in danger!
2. Warn other people!
3. Shut down the fireplace if possible!
4. Call the fire service!
1.10.2
In the event of a chimney fire
SAFETY INSTRUCTION
Temperatures above 1,000 °C can be produced in the
event of a chimney fire.
Never use water to put out the fire as there can be
explosive vapours and their volume can be increased
considerably (10 l water produces 17,000 l steam).
Soot deposits in the chimney can catch fire. They are caused
by the use of wood that is too wet or inadequate cleaning of
the chimney.
Correct behaviour in the event of a chimney fire:
1.
Reduce the combustion air supply!
2. Call the fire service!
3. Remove combustible materials (e.g. furniture) up the
full height of the chimney.
4. Provide access to the cleaning openings (e.g. basement
and loft).
Before lighting the fireplace again:
1.
Inform a technician/chimney sweep and check the
chimney for damage.
2. Determine the cause of the chimney fire with the
technician/chimney sweep and rectify it.
1.11
Fire protection
Comply with all state building regulations, fire regulations,
administrative and insurance-related regulations applicable
at the installation site. National and local regulations need
to be complied with. Should there not be fire protection
regulations in the country of installation, then we would
recommend adhering to the “Regulations governing fireplace
and air heating construction” (TROL).
1.11.1
Floor in front of the fire box opening
Floors made of combustible materials need to be protected
by a covering of non-combustible material in front of all fire
box openings. The covering needs to extend a minimum of
500 mm to the front and a minimum of 300 mm beyond the
fire box opening. There is no need for floor protection in front
of fire box openings that are only opened for cleaning and
maintenance, when operated as intended.
min. 500 mm
Fireplace
A
min.
300 mm
min.
300 mm
Fireplace insert
Fig. 3: Protection of the floor in the area in front of the fire
box opening, Lina, Lina TV
Description
:
A = Non-combustible floor covering