14
Operating Instructions
Isolating amplifier SIRAX TV 808-61
Contents
1. Read first and then... ................................................. 14
2. Scope of supply .........................................................14
3. Ordering informations .................................................14
4. Brief description .........................................................15
5. Overview of the parts .................................................15
6. Technical data ............................................................15
7. Mechanical coding of the plug-in module ..................16
8. Electrical connections ................................................16
9. Withdrawing and inserting the device ........................17
10. Configuration of the isolating amplifier ......................17
11. Mounting ....................................................................18
12. Commissioning ...........................................................18
13. Maintenance ...............................................................18
14. Releasing the isolation amplifier .................................18
15. Dimensional drawing ..................................................18
16. Declaration of conformity ...........................................19
1. Read first and then …
The proper and safe operation of the device
assumes that the Operating Instructions
are
read
and the safety warnings given in
the various Sections
7. Mechanical coding of the
plug-in module
8. Electrical connections
11. Mounting
12. Commissioning
are
observed
.
The device should only be handled by appropriately trained
personnel who are familiar with it and authorised to work
in electrical installations.
The instrument must only be opened for configuration,
as described in section “10. Configuration of the isolating
amplifier”!
The guarantee is no longer valid if the instrument is further
tampered with!
2. Scope of supply
(Fig. 1)
(1)
(3)
GOSSEN
METRA
W
ATT
C
AM
ILL
E B
AU
ER
Konfiguration / Configuration SIRAX TV 808
Kanal 1
Channel 1
Kanal 2
Channel 2
Eingang
Input
Ausgang
Output
Anlage/Mess-Stelle
Plant/Measuring point
GOSSEN
METRA
W
ATT
C
AM
ILL
E B
AU
ER
Konfiguration / Configuration SIRAX TV 808
Kanal 1
Channel 1
Kanal 2
Channel 2
Eingang
Input
Ausgang
Output
Anlage/Mess-Stelle
Plant/Measuring point
GOSSEN
METRA
W
ATT
C
AM
ILL
E B
AU
ER
Anlage/Mess-Stelle
Messeingang
Fühlertyp
Temperatur-Messbereich
Messausgang
Anfahr-Festwert währ. 5 s
Einstellzeit
Bruchsignalisierung
Netzbrumm-Unterdrückung
Grenzwertfunktion
Konfiguration / Configuration SIRAX V 644
Plant/Measuring point
Measuring input
Sensor type
Temperature range
Measuring output
Start up value during 5 s
Setting time
Open-circ. superv.
Mains ripple suppression
Output contact
inactive
50 Hz
inactive
active
60 Hz
active
(2)
(5)
(4)
Aargauerstrasse 7
CH-5610 Wohlen/Switzerland
T41 56 618 21 11
T41 56 618 24 58
Telex 827 901 cbm ch
TV 808-61 B d-f-e
125 171
09.97
Betriebsanleitung
Trennverstärker SIRAX TV 808-61
Mode d’emploi
Amplificateur-Séparateur SIRAX TV 808-61
Operating Instructions
Isolating amplifier SIRAX TV 808-61
Isolating amplifier (1)
3
Data cards (2)
(for recording configured settings)
1
Coding comb (3)
(for coding the backplane SIRAX BP 902)
1
Type Examination Certificate (4)
(for Ex version devices
only)
1
Operating Instructions (5)
, in three languages: German,
French, English
3. Ordering informations
DESCRIPTION
MARKING
1. Mechanical design
Housing B17
808 - 6
2. Number of channel
1 channel
1
3. Version / Power supply
Standard, 24 … 60 V DC/AC
1
Standard, 85 … 230 V DC/AC
2
[EEx ia] IIC, 24 … 60 V DC/AC
Input intrinsically safe
3
[EEx ia] IIC, 85 … 110 V DC/230 V AC
Input intrinsically safe
4
4. Function
1 input, 1 electrically insulated output
1
5. Input signal
Input
[V]
acc. to type label
9
Input
[mA]
acc. to type label
Z
6. Output signal
Output
[V]
acc. to type label
9
Output
[mA]
acc. to type label
Z
Содержание SIRAX TV 808-61
Страница 2: ...2 ...