EMC_SPEC018_C2.doc
Rev. D
–
2020 05 19
26/44
Install & Operating Manual
CamSafe
9.2
Intervention Space
For any operator intervention, access to CamSafe is from the front of the housing.
Actual minimal intervention space will depend on the housing size (filter dimensions), as well as on
some options & add-ons, such as WM door panels, a handling console or custom equipment.
Recommendations for safe and ergonomic minimum interventions space :
(values rounded to next 100 mm)
PLEASE NOTE:
As a general rule, 1
000 … 1
500 mm from the front of the housing should be
considered a minimum for safety- and ergonomic reasons.
To facilitate filter change, a handling table is available for both vertical and horizontal
flow housings (see also
).
Housing Space
[mm]
Min. Intervention Space
[mm]
STD
WM
Filter
Operator Recommended
3P3
600
600
400
600
1 000
3P6
600
600
400
600
1 000
6P6
900
900
700
600
1 300
7P6
1 100
1 100
800
600
1 400