![Camfil CamSafe Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/camfil/camsafe/camsafe_installation-and-operating-manual_487851022.webp)
EMC_SPEC018_C2.doc
Rev. D
–
2020 05 19
22/44
Install & Operating Manual
CamSafe
8.6
Installation of Add-ons
Support Stands
Add-on support stands are available for both vertical and horizontal airflow housings & stacks
and offer a modular and economic supporting solution.
•
Requires no housing modification, interfaces with the housing flange
•
For single filtration columns only
•
Horizontal stacks require 1 individual support per housing
•
Available in all housing base materials
For Vertical airflow
For Horizontal airflow
PLEASE NOTE:
Standard support stands interface with the inside of module flanges.
Left and right support have to be inserted separately. Once united, they will hold the housing even
before flange bolts are secured.
•
Insert 1st support side
under the module flange.
Temporarily secure with 2 screws against slipping.
•
Insert 2nd support side
under the module flange.
temporarily secure with 2 screws against slipping.
•
Attach support reinforcements
.
After this stage, the housing is safely captured
by the support stand interface.
•
Place gasket and next module or collector on top
.
•
Insert flange bolts in matching holes and tighten,
see also § 8.1
AIR
AIR
A
I
R
A
I
R
16
M10
13
M8