16
TC-003001-30 / Rev 01
Feb-02
Warning: Back up the seat grease fitting so only the safety vent cap will be removed from the fitting. Carefully
remove the safety cap from the seat grease fitting. NEVER remove the grease fitting when the valve is under
pressure.
3.
Remove safety vent cap from grease fitting. Attach grease gun connection onto grease fitting and inject
sealant. If injection of the sealant is difficult, flush the valve seats and attempt to inject sealant again.
4.
Repeat process for the second seat grease fitting as applicable, or the stem fitting. Replace safety caps on
all grease fittings.
Figure 4 – Typical Injection Fitting
Figure 5 – Vent or Bleed Fitting
Table 5 shows a list of recommended lubricants by the cleaner/sealant manufacturer for the indicated service and
conditions. Use of other lubricants without WKM approval voids all warranty and claims. Contact WKM
representatives for availability.
Table 5 – Manufacturer Recommended Lubricants
Flush/Sealant Recommendations
Service
Condition
Product
Cleaner/Sealant Manufacturer
The valve Cleaner/Sealant
Manufacturer's contact
information can be found below:
WKM
VAL-TEX
Natural
Gas
Flush
Valve flush
Headquarters
Cameron Valves & Measurement
3250 Brairpark Drive, Suite 300
Houston, TX 77042
Tel. (281) 499-8511
Order 1-800 323-9160
Fax (281) 261-3588
Standard valve lubricant
WKM 58G
2000 light lube
Standard sealant
WKM 103
80 bulk/ 80-HS stick
Standard low Temp.
50 bulk / stick
Severe leak sealant
80+PTFE bulk / stick
Sour Gas
Flush
Valve flush
Standard valve lubricant
WKM 58G
2065 light lube
Standard sealant
WKM 103
65 bulk / stick