Strobe Mode
The VT Camera Link cameras can output pulse signals through the control I/O receptacle. You can set a width of
the pulse signal by using the
Strobe Mode
parameter. This feature is useful when you need to supply source
signals to the other devices such as a Strobe Controller.
The commands related to Strobe Mode are as follows.
Configurator Parameters
Command
Value
Description
Strobe Mode
ssm 0
Off
Disables the Strobe Mode feature.
ssm 1
Timed
Outputs pulse signals according to the Strobe
Duration setting values.
ssm 2
Pulse Width
Outputs pulse signals of which the period is
equal to the trigger signals applied to the
camera.
ssm 3
On
Outputs continuous High signals.
Strobe Inverter
ssp 0
-
Deselect not to invert the output signal.
ssp 1
-
Select to invert the output signal.
Strobe Duration
ssr f
1.00 ~ 1000.00
Sets a duration of the pulse signal in
microseconds when the Strobe Mode is set to
Timed.
Strobe Delay
sto f
0.00 ~ 1000.00
Sets a delay to the current output signal in
microseconds.