P
age
28
- Manual
FA01554-EN
- 01/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Thrust
Before every opening or closing manoeuvre, the leaves thrust inwards to release the electric lock.
The command operates during opening or closing, depending on where the electric lock is active (see function
[F17 electric lock]).
F16
Thrust
OFF (Default)
ON
Electric lock
Associate the electric lock release with a command.
F17
Electric lock
OFF (Default)
1 = Opening
2 = Closing
3 = Opening and closing
4 = Continues during opening and closing
Additional light
Choose the operating mode for the lighting device connected to output E3.
F18
Additional light
0 = OFF (Default)
1 = Cycle light
The lamp stays on during the manoeuvre.
The light remains off if an automatic closing time
is not set.
2 = Courtesy lamp
The lighting device remains on for the full duration of the
manoeuvre and after the manoeuvre, for the time set
under the function [F25 Courtesy time].
Automatic closure
Set the time before automatic closure is activated, once the opening travel end point has been reached.
The function does not work if any of the safety devices are triggered when an obstacle is detected, after a
complete stop, during a power outage or if there is an error.
F19
Automatic close
OFF (Default)
From 1 to 180 seconds
Automatic closing after either partial or pedestrian opening.
Set the time before automatic closure is activated, after a partial opening command has been performed.
The function does not work if any of the safety devices are triggered when an obstacle is detected, after a
complete stop, during a power outage or if there is an error.
F20
Automatic partial close
OFF
1 to 180 seconds (Default 10)
Pre-fl ashing time
Set the time for which the beacon is activated before each manoeuvre.
F21
Pre-fl ashing time
OFF (Default)
1 to 10 seconds