p.
17
- M
an
ua
l
FA
010
82
-E
N
- 0
2/
20
18 - © C
AM
E S
.p
.A
. - T
ra
ns
la
tio
n o
f t
he o
rig
in
al i
ns
tru
ct
io
ns
Menu 1st level
Menu 2nd level
Options
Default
Setting the slow-down starting point before the closing limit-switch, calculated as
a percentage of the complete gate swing.
&
This function only appears if the
[Enc. Slodwn.] function
in the
[ENCODER]
menu
.
[CL. Sftstp. %]
[1%]
……
[15%]
[15%]
Setting the latch-speed starting point before the opening limit-switch, calculated
as a percentage of the complete gate swing.
[OP. Sftstp.%]
[1%]
……
[15%]
[15%]
Setting the starting latch-speed point before the opening limit-switch, calculated
as a percentage of the complete gate swing.
[Calibrate Gate-
Swing]
[Confirm? (no)] / [Confirm? (yes)]
[Confirm? (no)]
Automatic calibration of the gate-leaf swing (see the CALIBRATING SWING
paragraph).
[SET TIMES]
[A.C.T]
[0 s]
……
[300 s]
[10 s]
Waiting time before the automatic closing, once the opening limit-switch point is
reached. The automatic closing does not work if any of the safety devices trigger
when an obstruction is detected, or after a total stop, or during a power outage.
[Partial A.C.T.]
[0 s]
……
[300 s]
[10 s]
Like the [ACT], applied to the partial opening.
[Working Time]
function
[10 s]
……
[150 s]
[90 s]
Gearmotor working time during opening and closing.
[Preflash T]
[1 s]
……
[60 s]
[5 s]
After an opening or closing command, before starting the maneuver the flashing
light connected to W-E flashes for the set time.
[Lock time]
[1 s]
……
[5 s]
[2 s]
Intervention time for the electrolock to release after each opening command.
[Jolt time]
[1 s]
……
[3 s]
[1 s]
The closing and opening jolt thrust-time of the geartmotors after each command.
[Part.open]
[5 s]
……
[60 s]
[10 s]
The time required to define the wanted partial-opening space.
[Court. Time]
[60 s]
……
[300 s]
[300 s]
For setting the lighting up time of the courtesy light connected to 10_E3.
[USERS]
[New User]
Entering up to 250 users and associating to each one a function of choice among
those included. Enter by using a transmitter or other control device (see the
ENTERING A NEW USER paragraph).
[Edit. name]
For changing a user's number or name
[Edit Code]
To modify the command code that is associated to a user.
Содержание ZLJ14
Страница 43: ...p 19 Manual FA01082 EN 02 2018 CAME S p A Translation of the original instructions...
Страница 73: ...24 ZLJ14 RU FA01082 RU 24...
Страница 74: ...2 FA01082 RU 02 2018 CAME S p A 2006 42 CE 2006 42 CE CAME S p A...
Страница 75: ...3 FA01082 RU 02 2018 CAME S p A 1 5 III 50...
Страница 79: ...7 FA01082 RU 02 2018 CAME S p A 20...
Страница 84: ...B1 B2 2 FA FC S1 GND TS E E3 ES 1 2 3 3P 4 5 7 CX CY CZ 12 FA01082 RU 02 2018 CAME S p A USERS 500 A 24 RG58 F...
Страница 85: ...13 FA01082 RU 02 2018 CAME S p A 30...