Page
7
- Manual
- FA01940-EN
- 02/2023 © CAME S.p.A.
Command and control devices
1
STOP button (NC contact)
This stops the boom and excludes automatic closing. Use a control device to resume movement.
If the contact is not used, it must be deactivated during programming.
2
Control device (NO contact)
OPEN ONLY function
When the [HOLD-TO-RUN] function is active, the control device must be connected
during OPENING.
3
Control device (NO contact)
PARTIAL OPENING function
The contact must only be used for operators working in paired mode.
4
Control device (NO contact)
CLOSE ONLY function
When the [HOLD-TO-RUN] function is active, the control device must be connected
during CLOSING.
5
Control device (NO contact)
OPEN-CLOSE function
6
Antenna with RG58 cable
10 11 E1 E6 Rx Tx 1
2
3 3P 4
5
7
CY
CX