Page
14
- Manual
- FA01940-EN
- 02/2023 © CAME S.p.A.
Functions menu
Total stop
F1
This stops the operator and excludes automatic closing. Use a control device to resume
movement.
0 =Deactivated (Default)
1 = Activated
CX input and CY input
F2
F3
Associate a function with the input CX (F2) CY (F3).
0 =Deactivated (Default)
C1 = Reopen while closing (photocells)
C4 = Obstacle standby (photocells)
C5 = Immediate closure at the travel end during opening
C9 = Immediate closure at the travel end during opening with obstacle standby during
closure
Safety devices test
F5
Check that the photocells connected to the inputs are operating correctly, after each
opening and closing command.
0 =Deactivated (Default)
1 = CX
2 = CY
3 = CX+CY
Hold-to-run
F6
With the function active, the operator stops moving (opening or closing) when the control
device is released.
When the function is active, it excludes all other control devices.
0 =Deactivated (Default)
1 = Activated
Obstacle with motor stopped
F9
With the function active and the operator stopped, an open or close command is not
performed if the safety devices detect an obstacle.
0 =Deactivated (Default)
1 = Activated