CAME ZL371 Скачать руководство пользователя страница 1

FA01940-EN

88003-0156

EN

English

CAME S.p.A.

Via Martiri della 

Libertà, 15

31030 Dosson di Casier

Treviso – Italy

Tel. (+39) 0422 4940
Fax (+39) 0422 4941

[email protected]

www.came.com

KIT COMPONENTS

1

 Control board ZL371

2

 Fuse 1.6A (line 230 V)

3

 Fuse 3.15A (line 120 V)

4

 Ferrite

5

 EMC fi lter

6

 Terminal block with fuse compartment

02/2023

 - FA01940-EN

 

88003-0156

Содержание ZL371

Страница 1: ...31030 Dosson di Casier Treviso Italy Tel 39 0422 4940 Fax 39 0422 4941 info came com www came com KIT COMPONENTS 1 Control board ZL371 2 Fuse 1 6A line 230 V 3 Fuse 3 15A line 120 V 4 Ferrite 5 EMC lt...

Страница 2: ...r power supply 5 Terminal block for connecting the accessories 6 Terminal board for power supply to the control board 7 Accessories fuse 8 Control board fuse 9 Display 10 Connector for plug in radio f...

Страница 3: ...Page 3 Manual FA01940 EN 02 2023 CAME S p A INSTALLING...

Страница 4: ...age 4 Manual FA01940 EN 02 2023 CAME S p A ELECTRICAL CONNECTIONS Before working on the control panel cut off the mains power supply Red cable White cable Black cable Cable provided 120 230 V AC ZL37F...

Страница 5: ...Page 5 Manual FA01940 EN 02 2023 CAME S p A Always insert the line fuse in the terminal block 120 230 V AC ZL371 M...

Страница 6: ...ts The total power of the outputs listed below must not exceed the maximum output power Accessories Device Output Power supply V Power W Accessories 10 11 24 AC 40 Additional light 10 E1 24 AC 25 Flas...

Страница 7: ...OPEN ONLY function When the HOLD TO RUN function is active the control device must be connected during OPENING 3 Control device NO contact PARTIAL OPENING function The contact must only be used for o...

Страница 8: ...reases the light in the manoeuvring area 2 Additional flashing beacon It ashes when the operator opens and closes 3 Operator status warning light It noti es the user of the operator status 4 Rope ligh...

Страница 9: ...ut If contacts CX and CY are not used they must be deactivated during programming Multiple photocell pairs can be connected For Safety Devices Test mode please see the F5 function For Sleep mode pleas...

Страница 10: ...Mode 10 11 NO C NC 10 11 RX TX 10 11 E1 E6 Rx Tx 1 2 3 3P 4 5 7 CY CX DIR DELTA S photocells Standard connection Connection with safety test 10 2 TX C NC TX 2 RX TX 10 11 E1 E6 Rx Tx 1 2 3 3P 4 5 7 CY...

Страница 11: ...p Mode 10 2 TX C NC TX 2 RX TX 10 11 E1 E6 Rx Tx 1 2 3 3P 4 5 7 CY CX DXR DLX photocells Standard connection Connection with safety test RX TX 10 11 OUT 10 11 SY 10 11 E1 E6 Rx Tx 1 2 3 3P 4 5 7 CY CX...

Страница 12: ...Page 12 Manual FA01940 EN 02 2023 CAME S p A Connection with Sleep Mode RX TX 10 11 OUT 10 11 SY 10 11 E1 E6 Rx Tx 1 2 3 3P 4 5 7 CY CX...

Страница 13: ...nnections have been made proceed with commissioning Only skilled and quali ed staff may perform this operation Check the warning and safety devices are working properly Make sure that there are no obs...

Страница 14: ...el end during opening with obstacle standby during closure Safety devices test F5 Check that the photocells connected to the inputs are operating correctly after each opening and closing command 0 Dea...

Страница 15: ...cted to output E1 0 Flashing beacon Default 1 Cycle light The lamp stays on during the manoeuvre This parameter does not appear if the F19 Automatic Close function is deactivated 2 Courtesy lamp The l...

Страница 16: ...speed MIN minimum speed MED average speed MAX maximum speed Calibration speed F33 Set the travel self learning speed percentage of maximum speed 20 to 40 Travel sensitivity F34 It adjusts the obstacl...

Страница 17: ...49 function is set to Paired or Alternate 0 Deactivated Default 1 Activated CRP address F56 Assign a unique identi cation code CRP address to the control board from 1 to 255 Sleep mode F60 This reduce...

Страница 18: ...rd that manages the transmitters AF must be inserted into the connector 1 Step by step The rst command is to open and the second to close 3 Open 4 Partial opening When the barrier is in Paired mode th...

Страница 19: ...the transmitters Rolling code or TW key block any transmitters with a different type of radio coding saved previously will be deleted 1 All decoding default 2 Rolling code 3 TW key block Parameter res...

Страница 20: ...rds with a UTP CAT 5 cable Fit an RSE card on both control boards using the RSE connector Connect up the electrics for the devices and accessories For information on connecting the electrics for the d...

Страница 21: ...control board set as the MASTER Select function F49 Press ENTER to con rm Select 1 Press ENTER to con rm Select function F52 Press ENTER to con rm Select 1 Press ENTER to con rm For user storage opera...

Страница 22: ...ectronic boards with a UTP CAT 5 cable Fit an RSE card on both control boards using the RSE connector Connect up the electrics for the devices and accessories For information on connecting the electri...

Страница 23: ...rations described below must be performed only on the control board set as the MASTER Select function F49 Press ENTER to con rm Select 2 Press ENTER to con rm Select function F52 Press ENTER to con rm...

Страница 24: ...24 Manual FA01940 EN 02 2023 CAME S p A Operating modes The MASTER barrier is marked A the SLAVE barrier is marked B 1 ONLY OPEN command 2 3 on barrier A Barrier B opens automatically when barrier A c...

Страница 25: ...Page 25 Manual FA01940 EN 02 2023 CAME S p A 2 PARTIAL PEDESTRIAN OPENING command 2 3P on barrier B Barrier A opens automatically when barrier B closes...

Страница 26: ...Page 26 Manual FA01940 EN 02 2023 CAME S p A 3 STEP BY STEP command 2 7 on barrier A or B for emergency opening...

Страница 27: ...d safety device active The n value is associated with the selected parameter for the functions F2 CX input F3 CY input ERROR MESSAGES E4 Service test failure error E6 Maximum number of detected obstru...

Страница 28: ...ntents of this manual may be changed at any time and without notice Translation of the original instructions CAME S p A Via Martiri della Libert 15 31030 Dosson di Casier Treviso Italy Tel 39 0422 494...