
p.
22
-
M
an
u
al
c
od
e:
31
9
S
6
3
31
9
S
6
3
ve
r.
2.
0
2.
0
1
1/
2
0
11
© 1
1/
2
0
11 © C
A
M
E c
an
ce
lli auto
m
ati
ci
s.p.a. - T
h
e d
ata a
n
d i
nf
or
m
ati
on
in
th
is
m
an
u
al
m
ay b
e c
h
an
g
ed at a
ny tim
e a
n
d w
ith
ou
t
ob
lig
ati
on
o
n th
e p
art of C
am
e C
an
ce
lli A
uto
m
ati
ci
S
.p.a. to n
otify s
ai
d c
h
an
g
es.
ENGLISH
The overall power load of the connected operator must not exceed 320 W.
2.1 Intended use
1 Legend of symbols
2 Intended use and limits to use
The ZF1N control panel is suitable for swing gate operators of the ATI, FERNI, FAST, KRONO series that powered by 230 V.
Any installation and use other than that specified in this manual is forbidden.
3 Reference standards
"IMPORTANT INSTALLATION SAFETY INSTRUCTIONS"
“WARNING: IMPROPER INSTALLATION MAY RESULT IN SERIOUS HARM. PLEASE FOLLOW ALL INSTALLATION INSTRUCTIONS”
“THIS MANUAL IS INTENDED ONLY FOR PROFESSIONAL INSTALLERS OR OTHER COMPETENT INDIVIDUALS”
2.2 Limits to use
Came Cancelli Automatici employs an ISO 9001:14001 certified quality management system and an ISO 14001 environmental
management system. Came entirely engineers and manufactures in Italy.
This product is compliant with:
see statement of compliance.
Engineered and built entirely by Came Cancelli Automatici
S.p.A.
Power supply 230 V AC on terminals L1 and L2. The control panel
is protected by a 5 A fuse, while the low voltage accessories (24
V) are protected by a 3.15 A fuse.
Warning! The overall power of the 24 V accessories must not
exceed 20 W.
All connections are protected by quick fuses, see table.
The card provides and controls the following functions:
- automatic closing after an opening command;
- maintained action command.
The available command modes are:
- opening/closing;
- total stop.
The photocells, after detecting an obstacle, may trigger:
- the reopening of the closing gate;
- a total stop.
Specific trimmers regulate:
- the working time for automatic closing;
- the delayed closing time of operator 2;
- the working time.
You can also connect:
- 12 V electro-lock
- gate open warning-lamp.
This symbol shows parts which must be read with care.
This symbol means the parts which describe safety issues.
This symbol tells you what to tell the end-user.
FUSE TABLE
to protect: fuses for:
Electronic board (line)
A 5
Command devices and accessories
(control unit
3.15A
TECHNICAL DATA
Power supply 230 V - 50/60 Hz
Maximum allowed power load
320 W
Power draw when idle
40 mA
maximum power for 24 V accessories 20W
Circuit insulation class
Container material ABS
Container protection rating IP54
Working temperature - 20 / +55°C
4 Description
Содержание Z Series
Страница 13: ...R Q W U R O V O L Q H SERIES Z INSTALLATION MANUAL ZF1N CONTROL PANEL FOR 230 V OPERATORS English EN 319S63EN...
Страница 37: ...R Q W U R O V O R U H Z ZF1N 230 RU 319S63RU...
Страница 40: ...4 4 319S63 319S63 2 0 2 0 11 2011 CAME CANCELLI AUTOMATICI S p A 3 1 6 2 23 29 37 3 5 3 5 5 1 5 2...
Страница 46: ...2 1 2 1 10 10 319S63 319S63 2 0 2 0 11 2011 CAME CANCELLI AUTOMATICI S p A 1 PROG AF PROG 2 AF PROG...