MAINTENANCE
TROUBLES
POSSIBLE CAUSES
FIXES
It neither opens nor
closes
• Power supply is missing
• The gearmotor is stuck
• The transmitter doesn't work
• The transmitter is broken
• The stop button is either stuck or broken
• The opening/closing button or the key-switch
selector is stuck
• The wireless accessory does not work
• Check main power supply
• Lock the gearmotor
• Replace the batteries
• Call for assistance
• Call for assistance
• Call for assistance
• Call for assistance
The gate opens but
does not close
• The photocells are dirty
• Clean and check proper
functioning of the photocells
TROUBLESHOOTING
MAINTENANCE
Periodic maintenance
☞
Before any maintenance job, cut off the mains power supply, to prevent hazardous situations due to accidental
movement of the operator.
Periodic maintenance log to be fi lled in by users every six months.
ERROR MESSAGE
The error messages are shown on the display.
E 1
The travel calibration was interrupted when the STOP button was activated
E 2
Calibrating the complete gate-travel
E 3
Encoder broken
E 4
Services test error
E 7
Insuffi cient working time
E 8
The NC contacts are open (for example, the limit-switches)
E 9
Closing obstruction
E 10
Opening obstruction
E 11
Maximum number of detected obstructions
E 14
Serial communication error
E 17
Wireless system error
E 18
The wireless system confi guration is missing