Select A 3.
Press ENTER to confi rm.
Select 1 and press ENTER to confi rm the
travel calibration operation.
The gate will perform a closing maneuver
until it reaches a fi nal stop...
...then the gate will perform an opening
maneuver until it reaches a fi nal stop.
Travel calibration
Before calibrating the gate travel, position the gate half-way, check that the maneuvering area is clear of any
obstruction and check that there are mechanical opening and closing stops.
⚠
The mechanical end-stops are obligatory.
Important! During the calibration, all safety devices will be disabled except for the PARTIAL STOP one.
Memory Roll Card
To memorize user data and confi gure the system, to then reuse them with another control board even on another
system.
After memorizing the data, it is best to remove the Memory Roll.
Memory Roll.