10.1 Preparing the entrance and exit unit
The following illustrations are only examples, given that the space for securing the entrance and exit units and
accessories varies depending on the overall dimensions. The installation technician is responsible for choosing the most
suitable solution.
- Assemble the 4 anchor bolts to the plate.
-
Perform excavation for the foundation slab where to fi x the
mounting plate.
Recommended minimum size: 800x500x500 mm, taking into
account the raised base (see dimensions on p. 8).
NOTE: The mounting plate is to be cemented on the raised base
of 120 mm from the road surface.
Set up corrugated tubes for the connections coming from the
junction box.
N.B. the tube diameter depends on the type of system installed
and any accessories.
- Remove nuts and washers from the protruding bolts, place the cabinet on the base
and secure it.
Note: Install the cabinet with the inspection door facing the easiest to reach direction.
-
Fill the hole with concrete * and immerse the fi xing base (= plate +
brackets) making sure that the corrugated tubing protrude through
the hole arranged on the plate and id not fi lled with cement. Fit
the corrugated tubes into the left hole with the power supply and
ground while fi tting the Ethernet connection and accessories into
the right hole. The base must be perfectly level, fully resting on the
concrete surface, clean on all sides and with the screw threads fully
on the surface. Wait for everything to solidify for at least 24 hours.
10
Entrance unit / exit unit - installation
Nut M12 UNI 5588
Screws M12 x 40 UNI 5739
Washer
Wear protective gloves when installing the system.
* CONCRETE TECHNICAL CHARACTERISTICS
The concrete must be resistant to plastic deformation
with slump cone lowering
between 4 and 7 cm (for a 30 cm conical mould, with, with a diameter of 10
cm at the top and 20 cm in the lower part) and which must be fi lled in 4 layers.
BINDERS
use Portland cement without artifi cial constituents of
CPA 325 type.
AGGREGATES
calibre 10/20 and consist of limestone or silica free
of salts and clays.
DOSAGE
350 kg/m³
(mm)