ENGLISH
9.2 Power supply and ETHERNET connection
- Ground the cabinet by connecting it to the site ground
connector using cables of at least 4 mm².
- Connect the ground points
between the two parts that
make up the cabinet with the supplied cable.
Power from the main electrical panel of the site to provide adequate all-pole disconnect device for
disconnecting line voltage (MCB + RCD). Required characteristics:
•
Circuit breaker with breaking current up to 16 A (230 V) or 25 A (120 V);
•
RCD with 30 mA sensitivity.
Before connecting the device, disable the external all-pole disconnecting device.
The minimum cross section of the double insulated cable must be based on the characteristics and size of the plant, and in any
event not less than 2.5 mm².
Connect the ground cable to the top element.