ENGLISH
- Position the cover and secure it.
11.5 Power supply
Power from the main electrical panel of the site to provide adequate all-pole disconnect device for
disconnecting line voltage (MCB + RCD). Required characteristics:
•
Circuit breaker with breaking current up to 16 A (230 V) or 25 A (120 V);
•
RCD with 30 mA sensitivity.
Before connecting the device, disable the external all-pole disconnecting device.
The minimum cross section of the double insulated cable must be based on the characteristics and size of the plant, and in any
event not less than 2.5 mm².
- Ground the unit by connecting it to the site ground connector
using cables of at least 4 mm².