COMBINED OPERATION
Single command of two connected operators.
Electrical connections
Connect the two electronic boards with a UTP CAT 5 cable.
Fit a RSE card on both control boards, using the RSE_1 connector.
Proceed with the electrical connection of the devices and accessories.
For electrical connections of the devices and accessories, see the ELECTRICAL CONNECTIONS chapter.
The devices and accessories must be connected to the control board which will be set as MASTER.
A B GND
A B GND
R G B
2
10
S1 GND
A B
11 E1 E6 TS 1
2
3 3P 4
5
7
2 CX CY CZ
FA FC
FCA CM1 FCC CM2
EB
MOTOR
BLOCK
ARM
+
RSE
A B GND
A B GND
R G B
2
24
1
2
3 3P 4
5
7
2 CX CY CZ
0
30 0
FA FC
TAMPER
FCA CM1 FCC CM2
EB
MOTOR
BLOCK
ARM
EB
+
RSE
UTP CAT 5 (max 1000 m)
Programming
All programming operations described below must be performed only on the control board set as MASTER.
Configure the RSE_1 port in [Combined].
Enable the sharing of parameters programmed on the Master barrier with the Slave barrier.
After programming the MASTER automation in [Combined], the second automation automatically becomes SLAVE.
Saving users
All user storage operations must be performed only on the control board set as MASTER.
For user storage operations, see the [New User] function.
Operating modes
1
OPEN-CLOSE command (2-7), OPEN ONLY (2-3) or CLOSE ONLY (2-4)
2
OPEN ONLY command (2-3P)
MASTER
SLAVE
1
MASTER
SLAVE