background image

WARNING!

Important instructions for the safety of people: 

READ CAREFULLY!

Foreword

• Use of the products must be restricted to its intended use 
(i.e. that for which it was expressly built for). Any other use is 
to be considered dangerous. Came Cancelli Automatici S.p.A. 
is not liable for any damage resulting from improper, wrongful 
or unreasonable use •  Keep these warnings with the installa-
tion and use manuals issued with the automated system.

Before installing 

(preliminary check: in case of a negative 

outcome, do not proceed before having 

complied with the safety obligations)

• Make sure that the parts you intend to automate are in 
good working order, and that they are  properly balanced 
and  aligned.  Also,  make  sure  that  proper  mechanical  stops 
are already in place • If the operator will be installed at a 
height  of  less  than  2.5  m  from  the  ground  or  other  access 
level, check whether you will need any protections and/or 
warnings • Any gate leaves, fi tted with pedestrian entrances, 
onto which you will install an operator, must have a blocking 
mechanism when the gate is in motion • Make sure that the 
opening of the automated gate is not an entrapment hazard 
as regards any surrounding fi xed parts • Do not mount the 
operator  upside  down  or  onto  any  elements  that  may  fold 
under its weight. If needed, add suitable reinforcements at 
the points where it is secured • Do not install onto gates on 
either an upward or downward slope (i.e. that are not on fl at, 
level ground) • Check that any lawn watering devices will not 
wet the gearmotor from the bottom up.

Installation

• Carefully section off the entire site to prevent unauthorised  
access, especially by minors and children • Be careful when 
handling operators that weigh more than 20 Kg (see installa-
tion manual). In such cases, employ proper weight handling 
safety equipment • All opening commands (e.g. buttons, key 
selectors, magnetic detectors, etc.) must be installed at least 
1.85 m from the gate’s area of operation perimeter - or where 
they cannot be reached from the outside of the gate. Also, 
the direct commands (e.g. push button, or proximity devices, 
etc.) must be installed at a height of at least 1.5 m and must 
not be accessible to the public • All ‘maintained action’ com-
mands, must be placed where the moving gate leaves, transit 
areas and driveways are completely visible • If missing, ap-
ply a permanent label that shows the position of the release 
mechanism • Before delivering to the client, verify that the 
system is EN 12453 (impact test) standard compliant. Make 
sure that the operator has been properly adjusted and that the 
safety and protection devices, as well as the manual release 

are working properly • Where necessary and in plain sight, 
apply the Warning Sings (e.g. gate plate).

Special instructions and 

advice for users

• Keep the gate’s area of operation clean and clear of any 
obstacles. Trim any vegetation that may interfere with the 
photocells • Do not allow children to play with the fi xed com-
mand  devices,  or  in  the  gate’s  area  of  operation.  Keep  any 
remote control devices (i.e. transmitters) away from the chil-
dren as well • Frequently check the system, to see whether 
any anomalies or signs of wear and tear appear on the moving 
parts, on the component parts, on the securing points, on the 
cables and any accessible connections. Keep any joints (i.e. 
hinges)  lubricated and clean, and do the same where fric-
tion may occur (i.e. slide rails) • Perform functional tests on 
photocells and sensitive edges, every six months. Keep glass 
panels constantly clean (use a slightly water-moistened cloth; 
do not use solvents or any other chemical products) • If the 
system requires repairs or modifi cations, release the operator 
and do not use it until safety conditions have been restored 
• Cut off the power supply before releasing the operator for 
manual openings. See instructions • Users are FORBIDDEN 
to carry out ANY ACTIONS THAT THEY HAVE NOT BEEN 
EXPRESSLY ASKED TO DO OR SO INDICATED in the manu-
als. Any repairs, modifi cations to the settings and extraor-
dinary maintenance MUST BE DONE BY THE TECHNICAL 
ASSISTANCE STAFF • On the periodic maintenance log, note 
down the checks you have done.

Special instructions and 

advice for all

• Avoid working near the hinges or moving mechanical parts 
• Stay clear of the gate’s area of operation when in motion • 
Do not resist the direction of movement of the gate; this may 
present a safety hazard • At all times be extremely careful 
about dangerous points that must be indicated by proper 
pictograms and/or black and yellow stripes • When using 
a selector or command in ‘maintained action’ mode, keep 
checking that there are no people in the area of operation of 
the moving parts. Do this until you release the command • 
The gate may move at any time without warning • Always cut 
the power when cleaning performing maintenance. 

Содержание g2500n

Страница 1: ...G2500 G2500N INSTALLATION MANUAL OPERATOR FOR STREET BARRIERS English EN 119GM02EN...

Страница 2: ...pletely visible If missing ap ply a permanent label that shows the position of the release mechanism Before delivering to the client verify that the system is EN 12453 impact test standard compliant M...

Страница 3: ......

Страница 4: ...2 Fixed rest for barrier arms G0257 Joint for the G0251 maximum length of the barrier arm is 2 0 m Important MakesurethatthecommandandsafetyequipmentandaccessoriesareCAMEoriginals thisensureseasy ands...

Страница 5: ...arm attachment flange with galvanised finish for blocking the barrier arm quickly and safely 4 Gearmotor release activated by a customised key 5 230VACpoweredmotor Irreversiblegearmotorwithcastalumin...

Страница 6: ...ator do the following Check that the installing the operator does not create and hazardous situations Setupasuitableomnipolarcut offdevice withdistancesgreaterthan3mmbetweencontacts withsectionedpower...

Страница 7: ...econsidered according to the total draw and actual distances 1 GARD unit 2 Control panel 3 Aluminium barrier arm 4 Red reflective strips 5 Movement flashing light 6 Small post for photocells 7 Safety...

Страница 8: ...four anchoring clamps to the plate Digapitfortheanchoringbaseandsetuptherequiredcorrugated tubes for the connections coming out of the junction pit N B the number of tubes depends on the type of inst...

Страница 9: ...h and fasten it to the arm supporting attachmentAusingthefoursupplied bolts Adjust the barrier vertically and horizontallybyusingtherespective inner B and C mechanical stops The spring supplied with t...

Страница 10: ...are powered by 24V Warning The accessories must not exceed 20 W overall All connections are protected by quick fuses see table The card provides and controls the following functions automatic closing...

Страница 11: ...utomatici S p A to notify said changes ENGLISH 1 Transformer 2 Working time adjuster trimmer 3 Automatic closing time adjuster trimmer 4 Radio frequency card socket 5 Connecting terminals 6 Transforme...

Страница 12: ...tici S p A to notify said changes ENGLISH 230 V AC motor Closing micro switch F FC Opening micro switch F FA Accessories power supply Power supply at 230 V AC Frequency 50 60 Hz Orange Brown Black Blu...

Страница 13: ...act rated for 24 V 3 W Max Notifies that the barrier is lowered It turns off when the barrier is raised Closing button N O contact Barrier arm closing command Stop button N C contact Buttontostopbarri...

Страница 14: ...H DIR Safety devices Reopening when closing N C Contact Inputforsafetydeviceslikephotocells compliantwith lawEN12978 Whilethebarrierislowering openingthe contact will invert movement until it is fully...

Страница 15: ...t obligation on the part of Came Cancelli Automatici S p A to notify said changes ENGLISH 6 4 Settings Connecting two barriers joined by a single command Make the connections on terminals A then conne...

Страница 16: ...cy card into the electronic board only AFTER CUTTING OFF THE POWER SUPPLY N B The electronic card recognises the radio frequency card only when it is powered up AF card Only for the AF43S AF43SM radio...

Страница 17: ...obligation on the part of Came Cancelli Automatici S p A to notify said changes ENGLISH Radio card PROGbutton Keep button pressed PROG button on the electroniccard TheLEDflashesONandOFF Pressthebutto...

Страница 18: ...s manifested Danger of hand crushing Danger high voltage Transit forbidden during operation Important general safety instructions 9 Maintenance 9 1 Periodic maintenance Periodicservicingperformedbyend...

Страница 19: ...ologextraordinarymaintenance repairandimprovementjobsdonebythespecialisedexternal firms N B All extraordinary maintenance jobs must be carried out by skilled technicians Extraordinary maintenance log...

Страница 20: ...The N C safety contacts are open The radio control does not work 2 14 16 6 Deactivate the master slave function The operator inverts the direction of travel 7 18 7 Check balancing and taughtness of sp...

Страница 21: ...ons DISPOSING OF THE PACKAGING The components of the packaging i e cardboard plastic etc are solid urban waste and may be disposed of without much trouble simply by separating them for recycling Befor...

Страница 22: ...alquier informaci n sobre la empresa los productos y asistencia en su idioma NL Voor meer informatie over het bedrijf de producten en hulp in uw eigen taal PT Para toda e qualquer informa o acerca da...

Отзывы: