background image

p. 

1

8

18

 - M

an

u

al

 c

od

e:  

11

9

G

M

0

2

11

9

G

M

0

2

 ve

r.

 

44

 0

5

/2

0

13 © C

A

M

E C

an

ce

lli

 A

uto

m

ati

ci

 S

.p.

A

. - T

h

e d

ata a

n

d i

nf

or

m

ati

on i

n th

is

 m

an

u

al

 m

ay b

e c

h

an

g

ed at a

ny ti

m

e a

n

d w

ith

ou

t o

b

lig

ati

on o

n th

e p

art of C

am

e C

an

ce

lli

 A

uto

m

ati

ci

 S

.p.

A

. to n

otify s

ai

d c

h

an

g

es.

ENGLISH 

Installer's stamp

Product name

Date of job

Technician's signature

Customer's signature

Job carried out _______________________________________________________________________________________
__________________________________________________________________________________________________
_______________________________________________________________________________________________

Installer's stamp

Product name

Date of job

Technician's signature

Customer's signature

Job carried out _______________________________________________________________________________________
__________________________________________________________________________________________________
_______________________________________________________________________________________________

9.3 Troubleshooting

PROBLEM

REF.

CHECK

The operator neither opens nor closes

1-2-3-4-
6-8-18

1 - Lock the inspection hatch using the key and check the release 
lock

The operator opens but does not shut.

4-7-10

2 - Deactivate the "maintained action" function via Dip-switch

The operator closes but does not open

4-7-9

3 - Check power supply and fuses 

The operator does not carry out the automatic 
closing

11-12-13

4 - The N.C. safety contacts are open

The radio-control does not work

2-14-16

6 - Deactivate the master-slave function

The operator inverts the direction of travel

7-18

7 - Check balancing and taughtness of springs

Only one radio-control works.

 22

8 -Deactivate the obstacle detection function via dip switch

The photocell does not work

12-23-24

9- Check opening limit-switch

The led warning light flashes quickly

4

10- Check closing limit-switch

The led warning light stays lit.

13

11- Activate "automatic closing" via the Dip-switch 

The operator does not fully complete cycle 7

12 - Check for the proper direction of travel

Cannot balance the arm

7-15

13 - Check the command devices

The operator does not decelerate

7-15

14 - Cut off and bring back power to card or check the TOP/TAM 
jumper on the AF43S card

The operator does not run on the emergency 
batteries

8-25-26

15 - Check the Arm length/applied accessories ratio”

The operator is slow when starting

7

Memorise the radio code again

18 - Adjust sensitivity

22 - Enter or duplicate the same code in all transmitters 

23 - Activate the photocell via Dip-switch

24 - Connect the photocells in series and not in parallel fashion

25 - Check the batteries

26 - Respect the polarities when powering up the photocells

Installer's stamp

Product name

Date of job

Technician's signature

Customer's signature

Job carried out _______________________________________________________________________________________
__________________________________________________________________________________________________
_______________________________________________________________________________________________

Содержание g2500n

Страница 1: ...G2500 G2500N INSTALLATION MANUAL OPERATOR FOR STREET BARRIERS English EN 119GM02EN...

Страница 2: ...pletely visible If missing ap ply a permanent label that shows the position of the release mechanism Before delivering to the client verify that the system is EN 12453 impact test standard compliant M...

Страница 3: ......

Страница 4: ...2 Fixed rest for barrier arms G0257 Joint for the G0251 maximum length of the barrier arm is 2 0 m Important MakesurethatthecommandandsafetyequipmentandaccessoriesareCAMEoriginals thisensureseasy ands...

Страница 5: ...arm attachment flange with galvanised finish for blocking the barrier arm quickly and safely 4 Gearmotor release activated by a customised key 5 230VACpoweredmotor Irreversiblegearmotorwithcastalumin...

Страница 6: ...ator do the following Check that the installing the operator does not create and hazardous situations Setupasuitableomnipolarcut offdevice withdistancesgreaterthan3mmbetweencontacts withsectionedpower...

Страница 7: ...econsidered according to the total draw and actual distances 1 GARD unit 2 Control panel 3 Aluminium barrier arm 4 Red reflective strips 5 Movement flashing light 6 Small post for photocells 7 Safety...

Страница 8: ...four anchoring clamps to the plate Digapitfortheanchoringbaseandsetuptherequiredcorrugated tubes for the connections coming out of the junction pit N B the number of tubes depends on the type of inst...

Страница 9: ...h and fasten it to the arm supporting attachmentAusingthefoursupplied bolts Adjust the barrier vertically and horizontallybyusingtherespective inner B and C mechanical stops The spring supplied with t...

Страница 10: ...are powered by 24V Warning The accessories must not exceed 20 W overall All connections are protected by quick fuses see table The card provides and controls the following functions automatic closing...

Страница 11: ...utomatici S p A to notify said changes ENGLISH 1 Transformer 2 Working time adjuster trimmer 3 Automatic closing time adjuster trimmer 4 Radio frequency card socket 5 Connecting terminals 6 Transforme...

Страница 12: ...tici S p A to notify said changes ENGLISH 230 V AC motor Closing micro switch F FC Opening micro switch F FA Accessories power supply Power supply at 230 V AC Frequency 50 60 Hz Orange Brown Black Blu...

Страница 13: ...act rated for 24 V 3 W Max Notifies that the barrier is lowered It turns off when the barrier is raised Closing button N O contact Barrier arm closing command Stop button N C contact Buttontostopbarri...

Страница 14: ...H DIR Safety devices Reopening when closing N C Contact Inputforsafetydeviceslikephotocells compliantwith lawEN12978 Whilethebarrierislowering openingthe contact will invert movement until it is fully...

Страница 15: ...t obligation on the part of Came Cancelli Automatici S p A to notify said changes ENGLISH 6 4 Settings Connecting two barriers joined by a single command Make the connections on terminals A then conne...

Страница 16: ...cy card into the electronic board only AFTER CUTTING OFF THE POWER SUPPLY N B The electronic card recognises the radio frequency card only when it is powered up AF card Only for the AF43S AF43SM radio...

Страница 17: ...obligation on the part of Came Cancelli Automatici S p A to notify said changes ENGLISH Radio card PROGbutton Keep button pressed PROG button on the electroniccard TheLEDflashesONandOFF Pressthebutto...

Страница 18: ...s manifested Danger of hand crushing Danger high voltage Transit forbidden during operation Important general safety instructions 9 Maintenance 9 1 Periodic maintenance Periodicservicingperformedbyend...

Страница 19: ...ologextraordinarymaintenance repairandimprovementjobsdonebythespecialisedexternal firms N B All extraordinary maintenance jobs must be carried out by skilled technicians Extraordinary maintenance log...

Страница 20: ...The N C safety contacts are open The radio control does not work 2 14 16 6 Deactivate the master slave function The operator inverts the direction of travel 7 18 7 Check balancing and taughtness of sp...

Страница 21: ...ons DISPOSING OF THE PACKAGING The components of the packaging i e cardboard plastic etc are solid urban waste and may be disposed of without much trouble simply by separating them for recycling Befor...

Страница 22: ...alquier informaci n sobre la empresa los productos y asistencia en su idioma NL Voor meer informatie over het bedrijf de producten en hulp in uw eigen taal PT Para toda e qualquer informa o acerca da...

Отзывы: