Opening button (

N.O. contact

- Barrier-arm opening command.

Command devices

Warning devices  

Barrier down/closed warning light Contact rated for:  24 V - 3 W Max.
- Notifi es that the barrier is lowered. It turns off  when the barrier is raised. 

Closing button (

N.O. contact

- Barrier-arm closing command. 

Stop button (

(N.C.) contact

.

- Button to stop barrier arm.  Excludes automatic closing. To resume move-
ment press the command button or transmitter key.

If unused, short-circuit contact 1-2.

Barrier raised/open warning-light  Contact rated for:  24 V - 3 W Max.
- Signals that barrier-arm is raised, and switches of when the barrier-arm is 
lowered.

230 V AC output for fl ashing light: 
- Flashes while barrier opens and closes. 

Command devices

if unused

Содержание g2500n

Страница 1: ...G2500 G2500N INSTALLATION MANUAL OPERATOR FOR STREET BARRIERS English EN 119GM02EN...

Страница 2: ...pletely visible If missing ap ply a permanent label that shows the position of the release mechanism Before delivering to the client verify that the system is EN 12453 impact test standard compliant M...

Страница 3: ......

Страница 4: ...2 Fixed rest for barrier arms G0257 Joint for the G0251 maximum length of the barrier arm is 2 0 m Important MakesurethatthecommandandsafetyequipmentandaccessoriesareCAMEoriginals thisensureseasy ands...

Страница 5: ...arm attachment flange with galvanised finish for blocking the barrier arm quickly and safely 4 Gearmotor release activated by a customised key 5 230VACpoweredmotor Irreversiblegearmotorwithcastalumin...

Страница 6: ...ator do the following Check that the installing the operator does not create and hazardous situations Setupasuitableomnipolarcut offdevice withdistancesgreaterthan3mmbetweencontacts withsectionedpower...

Страница 7: ...econsidered according to the total draw and actual distances 1 GARD unit 2 Control panel 3 Aluminium barrier arm 4 Red reflective strips 5 Movement flashing light 6 Small post for photocells 7 Safety...

Страница 8: ...four anchoring clamps to the plate Digapitfortheanchoringbaseandsetuptherequiredcorrugated tubes for the connections coming out of the junction pit N B the number of tubes depends on the type of inst...

Страница 9: ...h and fasten it to the arm supporting attachmentAusingthefoursupplied bolts Adjust the barrier vertically and horizontallybyusingtherespective inner B and C mechanical stops The spring supplied with t...

Страница 10: ...are powered by 24V Warning The accessories must not exceed 20 W overall All connections are protected by quick fuses see table The card provides and controls the following functions automatic closing...

Страница 11: ...utomatici S p A to notify said changes ENGLISH 1 Transformer 2 Working time adjuster trimmer 3 Automatic closing time adjuster trimmer 4 Radio frequency card socket 5 Connecting terminals 6 Transforme...

Страница 12: ...tici S p A to notify said changes ENGLISH 230 V AC motor Closing micro switch F FC Opening micro switch F FA Accessories power supply Power supply at 230 V AC Frequency 50 60 Hz Orange Brown Black Blu...

Страница 13: ...act rated for 24 V 3 W Max Notifies that the barrier is lowered It turns off when the barrier is raised Closing button N O contact Barrier arm closing command Stop button N C contact Buttontostopbarri...

Страница 14: ...H DIR Safety devices Reopening when closing N C Contact Inputforsafetydeviceslikephotocells compliantwith lawEN12978 Whilethebarrierislowering openingthe contact will invert movement until it is fully...

Страница 15: ...t obligation on the part of Came Cancelli Automatici S p A to notify said changes ENGLISH 6 4 Settings Connecting two barriers joined by a single command Make the connections on terminals A then conne...

Страница 16: ...cy card into the electronic board only AFTER CUTTING OFF THE POWER SUPPLY N B The electronic card recognises the radio frequency card only when it is powered up AF card Only for the AF43S AF43SM radio...

Страница 17: ...obligation on the part of Came Cancelli Automatici S p A to notify said changes ENGLISH Radio card PROGbutton Keep button pressed PROG button on the electroniccard TheLEDflashesONandOFF Pressthebutto...

Страница 18: ...s manifested Danger of hand crushing Danger high voltage Transit forbidden during operation Important general safety instructions 9 Maintenance 9 1 Periodic maintenance Periodicservicingperformedbyend...

Страница 19: ...ologextraordinarymaintenance repairandimprovementjobsdonebythespecialisedexternal firms N B All extraordinary maintenance jobs must be carried out by skilled technicians Extraordinary maintenance log...

Страница 20: ...The N C safety contacts are open The radio control does not work 2 14 16 6 Deactivate the master slave function The operator inverts the direction of travel 7 18 7 Check balancing and taughtness of sp...

Страница 21: ...ons DISPOSING OF THE PACKAGING The components of the packaging i e cardboard plastic etc are solid urban waste and may be disposed of without much trouble simply by separating them for recycling Befor...

Страница 22: ...alquier informaci n sobre la empresa los productos y asistencia en su idioma NL Voor meer informatie over het bedrijf de producten en hulp in uw eigen taal PT Para toda e qualquer informa o acerca da...