background image

R

p. 

66

 - M

an

u

al

 c

od

e:  

11

9

G

M

0

2

11

9

G

M

0

2

 ve

r.

 

44

 0

5

/2

0

13 © C

A

M

E C

an

ce

lli

 A

uto

m

ati

ci

 S

.p.

A

. - T

h

e d

ata a

n

d i

nf

or

m

ati

on i

n th

is

 m

an

u

al

 m

ay b

e c

h

an

g

ed at a

ny ti

m

e a

n

d w

ith

ou

t o

b

lig

ati

on o

n th

e p

art of C

am

e C

an

ce

lli

 A

uto

m

ati

ci

 S

.p.

A

. to n

otify s

ai

d c

h

an

g

es.

ENGLISH 

5.5 Setting up the operator base 

 

The following illustrations are just examples, in that the space for securing the operator and accessories depends on 

the overall measurements.  It is up to the installer to choose the most suited solution.

- Assemble the four anchoring clamps to the plate. 

- Dig a pit for the anchoring base and set up the required corrugated 
tubes for the connections coming out of the junction pit.  
N.B. the number of tubes depends on the type of installation 
and accessories used.

- Remove any protruding nuts or washers, position the cabinet onto the base and fasten it.

Note:  install the cabinet with the inspection fl ap facing an easily accessible direction. 

- Fill the pit with cement and sink the anchoring base (that is, the plate 
+ clamps) making sure the corrugated tubes pass through he hole set 
up on the plate and that they are not fi lled with cement. The base must 
be perfectly level, clean and with the bolt threading completely on the 
surface.
Wait at least 24 hrs for everything to solidify.

Содержание g2500n

Страница 1: ...G2500 G2500N INSTALLATION MANUAL OPERATOR FOR STREET BARRIERS English EN 119GM02EN...

Страница 2: ...pletely visible If missing ap ply a permanent label that shows the position of the release mechanism Before delivering to the client verify that the system is EN 12453 impact test standard compliant M...

Страница 3: ......

Страница 4: ...2 Fixed rest for barrier arms G0257 Joint for the G0251 maximum length of the barrier arm is 2 0 m Important MakesurethatthecommandandsafetyequipmentandaccessoriesareCAMEoriginals thisensureseasy ands...

Страница 5: ...arm attachment flange with galvanised finish for blocking the barrier arm quickly and safely 4 Gearmotor release activated by a customised key 5 230VACpoweredmotor Irreversiblegearmotorwithcastalumin...

Страница 6: ...ator do the following Check that the installing the operator does not create and hazardous situations Setupasuitableomnipolarcut offdevice withdistancesgreaterthan3mmbetweencontacts withsectionedpower...

Страница 7: ...econsidered according to the total draw and actual distances 1 GARD unit 2 Control panel 3 Aluminium barrier arm 4 Red reflective strips 5 Movement flashing light 6 Small post for photocells 7 Safety...

Страница 8: ...four anchoring clamps to the plate Digapitfortheanchoringbaseandsetuptherequiredcorrugated tubes for the connections coming out of the junction pit N B the number of tubes depends on the type of inst...

Страница 9: ...h and fasten it to the arm supporting attachmentAusingthefoursupplied bolts Adjust the barrier vertically and horizontallybyusingtherespective inner B and C mechanical stops The spring supplied with t...

Страница 10: ...are powered by 24V Warning The accessories must not exceed 20 W overall All connections are protected by quick fuses see table The card provides and controls the following functions automatic closing...

Страница 11: ...utomatici S p A to notify said changes ENGLISH 1 Transformer 2 Working time adjuster trimmer 3 Automatic closing time adjuster trimmer 4 Radio frequency card socket 5 Connecting terminals 6 Transforme...

Страница 12: ...tici S p A to notify said changes ENGLISH 230 V AC motor Closing micro switch F FC Opening micro switch F FA Accessories power supply Power supply at 230 V AC Frequency 50 60 Hz Orange Brown Black Blu...

Страница 13: ...act rated for 24 V 3 W Max Notifies that the barrier is lowered It turns off when the barrier is raised Closing button N O contact Barrier arm closing command Stop button N C contact Buttontostopbarri...

Страница 14: ...H DIR Safety devices Reopening when closing N C Contact Inputforsafetydeviceslikephotocells compliantwith lawEN12978 Whilethebarrierislowering openingthe contact will invert movement until it is fully...

Страница 15: ...t obligation on the part of Came Cancelli Automatici S p A to notify said changes ENGLISH 6 4 Settings Connecting two barriers joined by a single command Make the connections on terminals A then conne...

Страница 16: ...cy card into the electronic board only AFTER CUTTING OFF THE POWER SUPPLY N B The electronic card recognises the radio frequency card only when it is powered up AF card Only for the AF43S AF43SM radio...

Страница 17: ...obligation on the part of Came Cancelli Automatici S p A to notify said changes ENGLISH Radio card PROGbutton Keep button pressed PROG button on the electroniccard TheLEDflashesONandOFF Pressthebutto...

Страница 18: ...s manifested Danger of hand crushing Danger high voltage Transit forbidden during operation Important general safety instructions 9 Maintenance 9 1 Periodic maintenance Periodicservicingperformedbyend...

Страница 19: ...ologextraordinarymaintenance repairandimprovementjobsdonebythespecialisedexternal firms N B All extraordinary maintenance jobs must be carried out by skilled technicians Extraordinary maintenance log...

Страница 20: ...The N C safety contacts are open The radio control does not work 2 14 16 6 Deactivate the master slave function The operator inverts the direction of travel 7 18 7 Check balancing and taughtness of sp...

Страница 21: ...ons DISPOSING OF THE PACKAGING The components of the packaging i e cardboard plastic etc are solid urban waste and may be disposed of without much trouble simply by separating them for recycling Befor...

Страница 22: ...alquier informaci n sobre la empresa los productos y asistencia en su idioma NL Voor meer informatie over het bedrijf de producten en hulp in uw eigen taal PT Para toda e qualquer informa o acerca da...

Отзывы: