Closing approach point
for motor M1
Adjusting as a percentage of the total travel, the M1 motor's closing-
approach starting point.
This function only appears if the Encoder function is activated.
1
= 1% of the gate travel /…/
10
= 10% of the gate travel (
default
)
F41
Opening slow-down
point for motor M2
Adjusting as a percentage of the total travel, the M2 motor's opening slow-
down starting point.
This function only appears if the Encoder function is activated.
1
= 1% of the gate travel /…/
25
= 25% of the gate travel (
default
) /…/
60
= 60% of the gate travel
F42
Closing slow-down point
for motor M2
Adjusting as a percentage of the total travel, the M2 motor's closing slow-
down starting point.
This function only appears if the Encoder function is activated.
1
= 1% of the gate travel /…/
25
= 25% of the gate travel (
default
) /…/
60
= 60% of the gate travel
F43
Opening approach
point for motor M2
Adjusting as a percentage of the total travel, of the M2 motor's opening
approach starting point.
This function only appears if the Encoder function is activated.
1
= 1% of the gate travel /…/
10
= 10% of the gate travel (
default
)
F44
Closing approach
point for motor M2
Adjusting as a percentage of the total travel, the M2 motor's closing approach
starting point.
This function only appears if the Encoder function is activated.
1
= 1% of the gate travel /…/
10
= 10% of the gate travel (
default
)
F46
Number of motors
For setting the number of motors connected to the control panel.
OFF
= M1 and M2
(default) / ON
= M2
F49
Managing the serial
connection
For enabling the CRP (Came Remote Protocol).
OFF
/
3
= CRP (
default
)
F50
Saving data
Saving users and saved settings in memory roll.
This function only appears if a memory roll has been fitted into the control
board.
OFF
(
default
) /
ON
F51
Reading of data
Uploading data saved in memory roll.
This function only appears if a memory roll has been fitted into the control
board.
OFF
(
default
) /
ON
F56
Peripheral number
To set the peripheral's number from 1 to 255 for each control board when you
have a system with several operators.
1 ----> 255
F63
COM speed
For setting the communication speed used in the CRP (Came Remote
Protocol) connection system.
0
= 1200 Baud /
1
= 2400 Baud /
2
= 4800 Baud /
3
= 9600 Baud /
4
=
14400 Baud /
5
= 19200 Baud /
6
= 38400 Baud (
default
) /
7
= 57600
Baud /
8
= 115200 Baud