Closing approach point 
for motor M1

Adjusting as a percentage of the total travel, the M1 motor's closing-
approach starting point.

 

This function only appears if the Encoder function is activated.

= 1% of the gate travel /…/ 

10 

= 10% of the gate travel (

default

)

F41

Opening slow-down 
point for motor M2

Adjusting as a percentage of the total travel, the M2 motor's opening slow-
down starting point.

 This function only appears if the Encoder function is activated.

1

 = 1% of the gate travel /…/ 

25

 = 25% of the gate travel (

default

) /…/ 

60

 

= 60% of the gate travel

F42

Closing slow-down point 
for motor M2

Adjusting as a percentage of the total travel, the M2 motor's closing slow-
down starting point.

 This function only appears if the Encoder function is activated.

1

 = 1% of the gate travel /…/ 

25

 = 25% of the gate travel (

default

) /…/ 

60

 

= 60% of the gate travel

F43

Opening approach 
point for motor M2

Adjusting as a percentage of the total travel, of the M2 motor's opening 
approach starting point.

 

This function only appears if the Encoder function is activated.

= 1% of the gate travel /…/ 

10 

= 10% of the gate travel (

default

)

F44

Closing approach 
point for motor M2

Adjusting as a percentage of the total travel, the M2 motor's closing approach 
starting point.

 

This function only appears if the Encoder function is activated.

= 1% of the gate travel /…/ 

10 

= 10% of the gate travel (

default

)

F46

Number of motors

For setting the number of motors connected to the control panel.

OFF 

= M1 and M2

 (default) / ON 

= M2

F49

Managing the serial 
connection

For enabling the CRP (Came Remote Protocol).

OFF

 / 

= CRP (

default

)

F50

Saving data

Saving users and saved settings in memory roll.

 This function only appears if a memory roll has been fitted into the control 

board.

OFF

 (

default

) / 

ON

F51

Reading of data

Uploading data saved in memory roll.

 This function only appears if a memory roll has been fitted into the control 

board.

OFF

 (

default

) / 

ON

F56

Peripheral number

To set the peripheral's number from 1 to 255 for each control board when you 
have a system with several operators.

1 ----> 255

F63

COM speed

For setting the communication speed used in the CRP (Came Remote 
Protocol) connection system.

0

 = 1200 Baud / 

1

 = 2400 Baud / 

2

 = 4800 Baud / 

3

 = 9600 Baud / 

4

 = 

14400 Baud / 

5

 = 19200 Baud / 

6

 = 38400 Baud (

default

) / 

7

 = 57600 

Baud / 

8

 = 115200 Baud

Содержание FTX20DGC

Страница 1: ...Swing gate operator FTX20DGC FTX20DLC INSTALLATION MANUAL EN English FA00441 EN...

Страница 2: ...p 2 Manual FA00441 EN 08 2018 CAME S p A Translation of the original instructions...

Страница 3: ...1 3 2 3 2 3 1 2 1 3 2 3...

Страница 4: ...spicious and unexpected behavior is experienced on the system call for qualified assistance MAINTENANCE WHEN CLEANING MAINTAINING AND REPLACING PARTS DISCONNECT THE OPERATOR FROM THE MAINS POWER SUPPL...

Страница 5: ...upside down or onto elements that could yield to its weight If necessary add reinforcements to the fastening points check that the temperature range appearing on the operator is suited to the place o...

Страница 6: ...nufacturer or by an authorized technical assistance center or in any case by qualified staff to prevent any risk During all phases of the installation make sure you have cut off the mains power source...

Страница 7: ...o 2 m INTENDED USE This operator is designed to power swing gates for residential and apartment block use Any installation and or use other than that specified in this manual is forbidden LIMITS TO US...

Страница 8: ...8 CAME S p A Translation of the original instructions DESCRIPTION OF PARTS 1 Cover 2 Control board protective cover 3 EMC02 card 4 Post brace 5 Gearmotor 6 Mechanical stops 7 Release lever 8 Lock 9 Co...

Страница 9: ...by consumption W 7 Stand by consumption with the RGP1 W module 0 5 Maximum power W 140 Cycles hour 40 Operating temperature C 20 to 55 Torque Nm 180 Opening time at 90 s from 20 to 30 Gear ratio 1 168...

Страница 10: ...e lengths differ from those specified in the table establish the cable sections depending on the actual power draw of the connected devices and according to the provisions of regulation CEI EN 60204 1...

Страница 11: ...tallation with the gearmotor and transmission arms fitted to the left of the inward opening gate Fitting the gearmotor with the transmission arms to the right is done symmetrically Careful For outward...

Страница 12: ...instructions Leaf opening arc A B C 90 140 210 540 0 50 90 140 200 510 75 200 90 150 180 510 225 250 110 200 220 480 0 50 Leaf opening arc A B C max 90 140 420 150 90 160 180 380 150 110 200 220 400 5...

Страница 13: ...post brace FASTENING THE BRACES Marked the spots where the gate post brace and gate brace will be fitted The fastening measurements are listed in the paragraph titled CHECKING MEASUREMENTS AND APPLIC...

Страница 14: ...olts Fit the plug into the socket on the gearmotor drive shaft PREPARING AND FASTENING THE OPERATOR Remove the operator s cover in the following way open the lock protection cap fit the trilobe key in...

Страница 15: ...08 2018 CAME S p A Translation of the original instructions Fasten the driven arm to the transmission arm by using the pin the bolt and the washer Release the gearmotor and fasten the driven arm to t...

Страница 16: ...e leaf Fit the second stop against the opposite side of the arm and fasten it with the bolt FASTENING THE MECHANICAL STOPS Release the gearmotor When opening Entirely open the gate leaf Fit the stop u...

Страница 17: ...se adjust the endstop by turning the endless screw on the other endstop ESTABLISHING THE LIMIT SWITCH POINTS With the gearmotor released and the gate leaf closed adjust the closing limit switch grub s...

Страница 18: ...inals for signaling devices 2 Gearmotors with encoder terminals 3 Control devices terminals 4 Safety devices terminals 5 CRP connection terminals 6 Terminals for transponder devices 7 Keypad selector...

Страница 19: ...441 EN 08 2018 CAME S p A Translation of the original instructions 24 V AC DC control board power supply input 24 V AC DC max 40 W accessories power supply output ELECTRICAL CONNECTIONS The electrical...

Страница 20: ...earmotors Connect the electric lock to the transformer s 17 V output and to terminal 5 on the control board WARNING To access the transformer you will need to remove the control board brace Transforme...

Страница 21: ...programming the functions you can activate the OPEN STOP CLOSE STOP sequential command OPEN or CLOSE See function F7 STOP button NC contact For stopping the gate while excluding automatic closing To r...

Страница 22: ...24 0 p 22 Manual FA00441 EN 08 2018 CAME S p A Translation of the original instructions BLUE BLACK BROWN BROWN BLACK BLUE BLUE BLACK BROWNE OPERATOR WITH GEARMOTOR OPERATORS BLUE BLACK BROWN Operator...

Страница 23: ...il the gate is fully open again C2 close back up during opening When the gate is opening opening the contact triggers the inversion of movement until the gate is completely closed C3 partial stop Open...

Страница 24: ...th the RIO CONN card the E 18 error message is displayed If the system has radiofrequency interferences the wireless system will inhibit the operator s normal operating mode and the E 17 error message...

Страница 25: ...or at least one second Display The keys are for moving from one item to another increasing or decreasing a value opening and closing the gate only when testing The ESC button is for exiting menus canc...

Страница 26: ...ic closing time function is activated OFF default C1 C2 C3 C4 C7 C8 F5 Safety test After every opening or closing command the board will check whether the photocells are working properly The safety te...

Страница 27: ...ric lock The thrust time is set with F 26 OFF default ON F18 Additional light Output for connecting the additional light onto 10 E Flashing light it flashes when the gate is opening and closing Cycle...

Страница 28: ...g the gearmotors speeds during calibration calculated as a percentage 20 20 of the maximum speed 50 50 of the maximum speed default 60 60 of the maximum speed F34 Travel sensitivity Adjusting obstruct...

Страница 29: ...ly appears if the Encoder function is activated 1 1 of the gate travel 10 10 of the gate travel default F44 Closing approach point for motor M2 Adjusting as a percentage of the total travel the M2 mot...

Страница 30: ...fitted with a RIO CONN card OFF default P1 P2 P3 P4 F68 Wireless input RIO CELL T2 RIO CELL is associated to any function chosen among those available P1 reopening during closing P2 reclosing during o...

Страница 31: ...ter powering up the system the first maneuver is always the opening In this phase the gate cannot be closed You will need to wait for the gate to completely open Immediately press the STOP button if a...

Страница 32: ...st procedure The following characters will be displayed while waiting for a command Keep pressed the key and check whether the M2 second gearmotor s leaf performs an opening maneuver If the leaf perfo...

Страница 33: ...d closing stops The mechanical end stops are obligatory Important During calibration all safety devices will be disabled Select A3 Press ENTER to confirm Select ON Press ENTER to confirm the automatic...

Страница 34: ...p close stop 3 open 4 partial opening Press ENTER to confirm a number between 1 and 250 will start flashing for a few seconds Send the code from the transmitter or other control device such as a keypa...

Страница 35: ...64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122...

Страница 36: ...60 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 2...

Страница 37: ...Manual FA00441 EN 08 2018 CAME S p A Translation of the original instructions DELETING SINGLE USERS Select U 2 Press ENTER to confirm Select ON Press ENTER to confirm the deletion procedure Use the ar...

Страница 38: ...18 CAME S p A Translation of the original instructions SAVING AND UPLOADING DATA WITH THE MEMORY ROLL For saving user and system configuration data with the Memory Roll and for then reusing them on an...

Страница 39: ...ncoder intervention zone with movement inversion D Encoder intervention zone with movement stopped E Opening slow down starting point for M2 F Closing slow down starting point for M2 G Opening slow do...

Страница 40: ...ions FASTENING THE TRANSMISSION ARM PROTECTION Fit the protection under the operator and fasten it to the transmission arm using the screw FINAL OPERATIONS FASTENING THE COVER Once the electrical conn...

Страница 41: ...PENING CONNECTIONS AND INSTALLING Following are the only things that change compared to a standard installation ERROR MESSAGE The error messages are shown on the display E1 The travel calibration was...

Страница 42: ...opening inwards When closing Close the leaf Fit the second stop against the opposite side of the arm and fasten it with the bolt FASTENING THE MECHANICAL STOPS Release the gearmotor When opening Entir...

Страница 43: ...ENC1 M2 N2 ENC2 p 43 Manual FA00441 EN 08 2018 CAME S p A Translation of the original instructions BLUE BLACK BROWN BLUE BLACK BROWN BLUE BLACK BROWN BLUE BLACK BROWN Operator fitted to the right and...

Страница 44: ...ing materials cardboard plastic and so on should be disposed of as solid household waste and simply separated from other waste for recycling Always make sure you comply with local laws before dismantl...

Отзывы: