Total stop [1-2]
NC input – Gate stop that excludes any automatic closing; to resume
movement, use the control device. The safety device should be fitted into
1-2. If unused, select OFF.
OFF
(
default
) /
ON
F2
Input [2-CX]
NC input – Can associate: C1 = reopening during closing by photocells, C2
= reclosing during opening by photocells, C3 = partial stop, C4 = obstruction
wait, C7 = reopening during closing by sensitive safety-edges (with clean
contact), C8 = reclosing during opening by sensitive safety-edges (with clean
contact).
The C3 Partial stop function only appears if the F 19 Automatic closing
time function is activated.
OFF
(
default
) /
C1
/
C2
/
C3
/
C4
/
C7
/
C8
F3
Input [2-CY]
NC input – Can associate: C1 = reopening during closing by photocells, C2
= reclosing during opening by photocells, C3 = partial stop, C4 = obstruction
wait, C7 = reopening during closing by sensitive safety-edges (with clean
contact), C8 = reclosing during opening by sensitive safety-edges (with clean
contact).
The C3 Partial stop function only appears if the F 19 Automatic closing
time function is activated.
OFF
(
default
) /
C1
/
C2
/
C3
/
C4
/
C7
/
C8
F5
Safety test
After every opening or closing command, the board will check whether the
photocells are working properly.
The safety test is always active for wireless devices.
OFF
(
default
) /
1
= CX /
2
= CY /
4
= CX+CY
F6
Maintained action
The gate opens and closes by keeping the button pressed. Opening button
on contact 2-3P and closing button on contact 2-7. All other control devices,
even radio-based ones, are excluded.
OFF
(
default
) /
ON
F7
Command [2-7]
From the control device connected to 2-7 it performs the step-step (open-
close-invert) or sequential (open-stop-close-stop) command.
0
= Step-step (
default
) /
1
= Sequential /
2
= Open /
3
= Close
F8
Command [2-3P]
From the control device connected to 2-3P it executes the pedestrian opening
(completely opens the M2 gate leaf) or partial opening (it partially opens the
M2 gate leaf: the opening arc depends on the percentage of travel set up
with F36).
0 = Pedestrian opening (default) / 1 = Partial opening /
2
= Open
F9
Obstruction detection
with motor stopped
With the gate closed, opened or totally stopped, the gearmotor stays idle
if the safety devices, that is, photocells or sensitive safety-edges detect an
obstruction.
OFF
(
default
) /
ON
⚠
When programming, the operator needs to be in stop mode.
FUNCTIONS MENU