background image

P

ag

e 2  - M

an

u

al c

od

e: 

11

9

A

U

0

3

E

N

11

9

A

U

0

3

E

N

 ve

rs

5

  0

3

/2

0

1

6  © C

A

M

E S

.p.

A

. - T

h

e d

ata a

n

d i

nf

or

m

ati

on p

rovi

d

ed i

n th

is m

an

u

al a

re s

u

b

je

ct to c

h

an

g

e at a

ny ti

m

e w

ith

ou

t p

rio

r n

ot

ic

e by C

A

M

E S

.p.

A

.

WARNING!

important safety instructions:

READ CAREFULLY!

Hand crushing hazard

Danger high voltage

No transit during operation 

Danger of foot crushing

P

REMISE

• E

MPLOY

 

THIS

 

PRODUCT

 

ONLY

 

FOR

 

THE

 

USE

 

FOR

 

WHICH

 

IT

 

WAS

 

EXPRESSLY

 

MADE

. A

NY

OTHER

 

USE

 

IS

 

DANGEROUS

. C

AME

 S.

P

.A. I

S

 

NOT

 

LIABLE

 

FOR

 

ANY

 

DAMAGE

 

CAUSED

 

BY

IMPROPER

WRONGFUL

 

AND

 

UNREASONABLE

 

USE

 • 

KEEP

 

THESE

 

WARNINGS

 

TOGETHER

 

WITH

THE

 

INSTALLATION

 

AND

 

OPERATION

 

MANUALS

 

THAT

 

COME

 

WITH

 

THE

 

OPERATOR

.

B

EFORE

 

INSTALLING

(C

HECKING

 

WHAT

'

S

 

THERE

IF

 

YOUR

 

EVALUATION

 

IS

 

NEGATIVE

DO

 

NOT

 

PROCEED

 

BEFORE

 

HAVING

 

COMPLIED

 

WITH

 

ALL

 

SAFETY

 

REQUIREMENTS

• C

HECK

 

THAT

 

THE

 

AUTOMATED

 

PARTS

 

ARE

 

IN

 

GOOD

 

MECHANICAL

 

ORDER

THAT

 

THE

OPERATOR

 

IS

 

LEVEL

 

AND

 

ALIGNED

AND

 

THAT

 

IT

 

OPENS

 

AND

 

CLOSES

 

PROPERLY

. M

AKE

 

SURE

YOU

 

HAVE

 

SUITABLE

 

MECHANICAL

 

STOPS

 • 

IF

 

THE

 

OPERATOR

 

IS

 

TO

 

BE

 

INSTALLED

 

AT

 

A

 

HEIGHT

OF

 

OVER

 2.5 M 

FROM

 

THE

 

GROUND

 

OR

 

OTHER

 

ACCESS

 

LEVEL

MAKE

 

SURE

 

YOU

 

HAVE

 

ANY

NECESSARY

 

PROTECTIONS

 

AND

/

OR

 

WARNINGS

 

IN

 

PLACE

 • 

IF

 

ANY

 

PEDESTRIAN

 

OPENINGS

 

ARE

FITTED

 

INTO

 

THE

 

OPERATOR

THERE

 

MUST

 

ALSO

 

BE

 

A

 

A

 

SYSTEM

 

TO

 

BLOCK

 

THEIR

 

OPENING

WHILE

 

THEY

 

ARE

 

MOVING

 • 

MAKE

 

SURE

 

THAT

 

THE

 

OPENING

 

AUTOMATED

 

DOOR

 

OR

 

GATE

CANNOT

 

ENTRAP

 

PEOPLE

 

AGAINST

 

THE

 

FIXED

 

PARTS

 

OF

 

THE

 

OPERATOR

 • 

DO

 

NOT

 

INSTALL

 

THE

OPERATOR

 

UPSIDE

 

DOWN

 

OR

 

ONTO

 

ELEMENTS

 

THAT

 

COULD

 

YIELD

 

AND

 

BEND

. I

F

 

NECESSARY

,

ADD

 

SUITABLE

 

REINFORCEMENTS

 

TO

 

THE

 

ANCHORING

 

POINTS

 • 

DO

 

NOT

 

INSTALL

 

DOOR

 

OR

GATE

 

LEAVES

 

ON

 

TILTED

 

SURFACES

 • 

MAKE

 

SURE

 

ANY

 

SPRINKLER

 

SYSTEMS

 

CANNOT

 

WET

 

THE

OPERATOR

 

FROM

 

THE

 

GROUND

 

UP

 • 

MAKE

 

SURE

 

THE

 

TEMPERATURE

 

RANGE

 

SHOWN

 

ON

 

THE

PRODUCT

 

LITERATURE

 

IS

 

SUITABLE

 

TO

 

THE

 

CLIMATE

 

WHERE

 

IT

 

WILL

 

BE

 

INSTALLED

 • 

FOLLOW

ALL

 

INSTRUCTIONS

 

AS

 

IMPROPER

 

INSTALLATION

 

MAY

 

RESULT

 

IN

 

SERIOUS

 

BODILY

 

INJURY

 • 

IT

IS

 

IMPORTANT

 

TO

 

FOLLOW

 

THESE

 

INSTRUCTIONS

 

FOR

 

THE

 

SAFETY

 

OF

 

PEOPLE

. K

EEP

 

THESE

INSTRUCTIONS

.

I

NSTALLING

• S

UITABLY

 

SECTION

 

OFF

 

AND

 

DEMARCATE

 

THE

 

ENTIRE

 

INSTALLATION

 

SITE

 

TO

 

PREVENT

UNAUTHORIZED

 

PERSONS

 

FROM

 

ENTERING

 

THE

 

AREA

ESPECIALLY

 

MINORS

 

AND

 

CHILDREN

BE

 

CAREFUL

 

WHEN

 

HANDLING

 

OPERATORS

 

THAT

 

WEIGH

 

OVER

 20 

KG

. I

F

 

NEED

 

BE

USE

PROPER

 

SAFETY

 

HOISTING

 

EQUIPMENT

 • 

ALL

 

OPENING

 

COMMANDS

 (

THAT

 

IS

BUTTONS

KEY

SWITCHES

MAGNETIC

 

READERS

AND

 

SO

 

ON

)  

MUST

 

BE

 

INSTALLED

 

AT

 

LEAST

 1.85 M 

FROM

THE

 

PERIMETER

 

OF

 

THE

 

GATE

'

S

 

WORKING

 

AREA

OR

 

WHERE

 

THEY

 

CANNOT

 

BE

 

REACHED

 

FROM

OUTSIDE

 

THE

 

GATE

. A

LSO

ANY

 

DIRECT

 

COMMANDS

 (

BUTTONS

TOUCH

 

PANELS

AND

 

SO

 

ON

)

MUST

 

BE

 

INSTALLED

 

AT

 

LEAST

 1.5 M 

FROM

 

THE

 

GROUND

 

AND

 

MUST

 

NOT

 

BE

 

REACHABLE

 

BY

UNAUTHORIZED

 

PERSONS

 • 

ALL

 

MAINTAINED

 

ACTION

 

COMMANDS

MUST

 

BE

 

FITTED

 

IN

 

PLACES

FROM

 

WHICH

 

THE

 

MOVING

 

GATE

 

LEAVES

 

AND

 

TRANSIT

 

AND

 

DRIVING

 

AREAS

 

ARE

 

VISIBLE

 •

APPLY

IF

 

MISSING

A

 

PERMANENT

 

SIGN

 

SHOWING

 

THE

 

POSITION

 

OF

 

THE

 

RELEASE

 

DEVICE

BEFORE

 

DELIVERING

 

TO

 

THE

 

USERS

MAKE

 

SURE

 

THE

 

SYSTEM

 

IS

 

EN

 12453 

STANDARD

COMPLIANT

 (

REGARDING

 

IMPACT

 

FORCES

), 

AND

 

ALSO

 

MAKE

 

SURE

 

THE

 

SYSTEM

 

HAS

 

BEEN

PROPERLY

 

ADJUSTED

 

AND

 

THAT

 

ANY

 

SAFETY

PROTECTION

 

AND

 

MANUAL

 

RELEASE

 

DEVICES

ARE

 

WORKING

 

PROPERLY

 • 

APPLY

 

WARNING

 

SIGNS

  (

SUCH

 

AS

 

THE

 

GATE

'

S

 

PLATE

WHERE

NECESSARY

 

AND

 

IN

 

A

 

VISIBLE

 

PLACE

S

PECIAL

 

USER

-

INSTRUCTIONS

 

AND

 

RECOMMENDATIONS

 

• K

EEP

 

GATE

 

OPERATION

 

AREAS

 

CLEAN

 

AND

 

FREE

 

OF

 

ANY

 

OBSTRUCTIONS

. M

AKE

 

SURE

 

THAT

THE

 

PHOTOCELLS

 

ARE

 

FREE

 

OF

 

ANY

 

OVERGROWN

 

VEGETATION

 

AND

 

THAT

 

THE

 

OPERATOR

'

S

AREA

 

OF

 

OPERATION

 

IS

 

FREE

 

OF

 

ANY

 

OBSTRUCTIONS

 • 

DO

 

NOT

 

ALLOW

 

CHILDREN

 

TO

 

PLAY

WITH

 

FIXED

 

COMMANDS

OR

 

TO

 

LOITER

 

IN

 

THE

 

GATE

'

S

 

MANEUVERING

 

AREA

. K

EEP

 

ANY

REMOTE

 

CONTROL

 

TRANSMITTERS

 

OR

 

ANY

 

OTHER

 

COMMAND

 

DEVICE

 

AWAY

 

FROM

 

CHILDREN

,

TO

 

PREVENT

 

THE

 

OPERATOR

 

FROM

 

BEING

 

ACCIDENTALLY

 

ACTIVATED

. • T

HE

 

APPARATUS

 

MAY

BE

 

USED

 

BY

 

CHILDREN

 

OF

 

EIGHT

 

YEARS

 

AND

 

ABOVE

 

AND

 

BY

 

PHYSICALLY

MENTALLY

 

AND

SENSORIALLY

 

CHALLENGED

 

PEOPLE

OR

 

EVEN

 

ONES

 

WITHOUT

 

ANY

 

EXPERIENCE

PROVIDED

 

THIS

HAPPENS

 

UNDER

 

CLOSE

 

SUPERVISION

 

OR

 

ONCE

 

THEY

 

HAVE

 

BEEN

 

PROPERLY

 

INSTRUCTED

 

TO

USE

 

THE

 

APPARATUS

 

SAFELY

 

AND

 

ABOUT

 

THE

 

POTENTIAL

 

HAZARDS

 

INVOLVED

. C

HILDREN

 

MUST

NOT

 

PLAY

 

WITH

 

THE

 

APPARATUS

. C

LEANING

 

AND

 

MAINTENANCE

 

BY

 

USERS

 

MUST

 

NOT

 

BE

 

DONE

BY

 

CHILDREN

UNLESS

 

PROPERLY

 

SUPERVISED

 • 

FREQUENTLY

 

CHECK

 

THE

 

SYSTEM

 

FOR

 

ANY

MALFUNCTIONS

 

OR

 

SIGNS

 

OF

 

WEAR

 

AND

 

TEAR

 

OR

 

DAMAGE

 

TO

 

THE

 

MOVING

 

STRUCTURES

TO

THE

 

COMPONENT

 

PARTS

ALL

 

ANCHORING

 

POINTS

INCLUDING

 

CABLES

 

AND

 

ANY

 

ACCESSIBLE

CONNECTIONS

. K

EEP

 

ANY

 

HINGES

MOVING

 

JOINTS

 

AND

 

SLIDE

 

RAILS

 

PROPERLY

 

LUBRICATED

PERFORM

 

FUNCTIONAL

 

CHECKS

 

ON

 

THE

 

PHOTOCELLS

 

AND

 

SENSITIVE

 

SAFETY

 

EDGES

EVERY

SIX

 

MONTHS

. T

O

 

CHECK

 

WHETHER

 

THE

 

PHOTOCELLS

 

ARE

 

WORKING

WAVE

 

AN

 

OBJECT

 

IN

FRONT

 

OF

 

THEM

 

WHILE

 

THE

 

GATE

 

IS

 

CLOSING

IF

 

THE

 

OPERATOR

 

INVERTS

 

ITS

 

DIRECTION

OF

 

TRAVEL

 

OR

 

SUDDENLY

 

STOPS

THE

 

PHOTOCELLS

 

ARE

 

WORKING

 

PROPERLY

. T

HIS

 

IS

 

THE

ONLY

 

MAINTENANCE

 

OPERATION

 

TO

 

DO

 

WITH

 

THE

 

POWER

 

ON

. C

ONSTANTLY

 

CLEAN

 

THE

PHOTOCELLS

GLASS

 

COVERS

 

USING

 

A

 

SLIGHTLY

 

WATER

-

MOISTENED

 

CLOTH

DO

 

NOT

 

USE

 

ANY

SOLVENTS

 

OR

 

OTHER

 

CHEMICAL

 

PRODUCTS

 

THAT

 

MAY

 

RUIN

 

THE

 

DEVICES

 • 

IF

 

REPAIRS

 

OR

MODIFICATIONS

 

ARE

 

REQUIRED

 

TO

 

THE

 

SYSTEM

RELEASE

 

THE

 

OPERATOR

 

AND

 

DO

 

NOT

 

USE

IT

 

UNTIL

 

SAFETY

 

CONDITIONS

 

HAVE

 

BEEN

 

RESTORED

 • 

CUT

 

OFF

 

THE

 

POWER

 

SUPPLY

 

BEFORE

RELEASING

 

THE

 

OPERATOR

 

FOR

 

MANUAL

 

OPENINGS

 

AND

 

BEFORE

 

ANY

 

OTHER

 

OPERATION

TO

PREVENT

 

POTENTIALLY

 

HAZARDOUS

 

SITUATIONS

. R

EAD

 

THE

 

INSTRUCTIONS

 • 

IF

 

THE

 

POWER

 

SUPPLY

 

CABLE

 

IS

 

DAMAGED

IT

 

MUST

 

BE

 

REPLACED

 

BY

 

THE

 

MANUFACTURER

 

OR

 

AUTHORIZED

 

TECHNICAL

 

ASSISTANCE

 

SERVICE

OR

 

IN

 

ANY

 

CASE

BY

 

SIMILARLY

 

QUALIFIED

 

PERSONS

TO

 

PREVENT

 

ANY

 

RISK

 • 

IT

 

IS

 

FORBIDDEN

 

FOR

 

USERS

 

TO

 

PERFORM

 

ANY

 

OPERATIONS

 

THAT

 

ARE

 

NOT

 

EXPRESSLY

 

REQUIRED

 

OF

 

THEM

 

AND

 

WHICH

 

ARE

 

NOT

 

LISTED

 

IN

 

THE

 

MANUALS

. F

OR

 

ANY

 

REPAIRS

MODIFICATIONS

 

AND

 

ADJUSTMENTS

 

AND

 

FOR

 

EXTRAORDINARY

 

MAINTENANCE

CALL

 

TECHNICAL

 

ASSISTANCE

 • 

LOG

 

THE

 

JOB

 

AND

 

CHECKS

 

INTO

 

THE

 

PERIODIC

 

MAINTENANCE

 

LOG

A

DDITIONAL

 

SPECIAL

 

RECOMMENDATIONS

 

FOR

 

EVERYONE

 

• K

EEP

 

AWAY

 

FROM

 

HINGES

 

AND

 

MECHANICAL

 

MOVING

 

PARTS

 • 

DO

 

NOT

 

ENTER

 

THE

OPERATOR

'

S

 

AREA

 

OF

 

OPERATION

 

WHEN

 

IT

 

IS

 

MOVING

 • 

DO

 

NOT

 

COUNTER

 

THE

 

OPERATOR

'

S

MOVEMENT

 

AS

 

THIS

 

COULD

 

RESULT

 

IN

 

DANGEROUS

 

SITUATIONS

 • 

ALWAYS

 

PAY

 

SPECIAL

ATTENTION

 

TO

 

ANY

 

DANGEROUS

 

POINTS

WHICH

 

HAVE

 

TO

 

BE

 

LABELED

 

WITH

 

SPECIFIC

PICTOGRAMS

 

AND

/

OR

 

BLACK

 

AND

 

YELLOW

 

STRIPES

 • 

WHILE

 

USING

 

A

 

SELECTOR

 

SWITCH

 

OR

A

 

COMMAND

 

IN

 

MAINTAINED

 

ACTIONS

KEEP

 

CHECKING

 

THAT

 

THERE

 

ARE

 

NO

 

PERSONS

 

WITHIN

THE

 

OPERATING

 

RANGE

 

OF

 

ANY

 

MOVING

 

PARTS

UNTIL

 

THE

 

COMMAND

 

IS

 

RELEASED

 • 

THE

GATE

 

MAY

 

MOVE

 

AT

 

ANY

 

TIME

 

AND

 

WITHOUT

 

WARNING

 • 

ALWAYS

 

CUT

 

OFF

 

THE

 

POWER

 

SUPPLY

BEFORE

 

PERFORMING

 

ANY

 

MAINTENANCE

 

OR

 

CLEANING

.

Содержание FROG MD

Страница 1: ...UNDERGROUND OPERATOR FOR SWING GATES 119AU03EN Installation manual FROG MD FROG MS English EN...

Страница 2: ...ATE S PLATE WHERE NECESSARY AND IN A VISIBLE PLACE SPECIAL USER INSTRUCTIONS AND RECOMMENDATIONS KEEP GATE OPERATION AREAS CLEAN AND FREE OF ANY OBSTRUCTIONS MAKE SURE THAT THE PHOTOCELLS ARE FREE OF...

Страница 3: ...bited Technical data Type FROG MD FROG MS Motor power supply V 50 60 Hz 230 400 AC Power supply V 50 60 Hz 230 400 AC Power W 600 Power draw A 2 5 max Torque Nm 1000 max Opening time to 95 sec 45 Gear...

Страница 4: ...16 CAME S p A The data and information provided in this manual are subject to change at any time without prior notice by CAME S p A Dimensions Description of the components 1 Tie rod 2 Motor arm 3 Gea...

Страница 5: ...u have all the tools and materials you will need for the installation at hand to work in total safety and compliance with current standards and regulations The figure shows some examples of installer...

Страница 6: ...Drainage chamber 11 Mechanical stops Laying the corrugated pipes and inspection chambers Make the hole for the box Prepare the junction boxes and corrugated pipes necessary for connection to the insp...

Страница 7: ...af will open Lean the box against the pillar making sure that the corrugated pipes and the drain pipe pass through the designated holes Fill the hole with concrete Position the box level with the grou...

Страница 8: ...hinge Check that the leaf opens and closes without difficulty Secure using suitable screws or weld the leaf carefully to the upper arm Securing the gearmotor N B the figures below are shown from the...

Страница 9: ...ny time without prior notice by CAME S p A Secure the tie rod between the motor arm and the arm unit in the prepared holes using nuts and bolts N B the arms have several holes in order to obtain vario...

Страница 10: ...f its run with the motor arm Secure the nuts Mechanical stop Motor arm R OUTER entry exit INNER L R OUTER entry exit INNER L Establishing the limit switch points For opening completely open the leaves...

Страница 11: ...y CAME S p A Three phase 230 VAC 50 60 Hz power supply Delayed closing gearmotor connection Three phase 400 VAC 50 60 Hz power supply Delayed opening gearmotor connection Delayed closing gearmotor con...

Страница 12: ...onnecting the close end run to the delayed opening gearmotor 3 Connecting the close end run to the delayed closing gearmotor 4 Connecting the open end run to the delayed closing gearmotor BLACK BLACK...

Страница 13: ...re the only procedures that vary compared to standard installations L R OUTER entry exit INNER L R OUTER entry exit INNER For closing completely shut the leaves turn the left hand gearmotor cam clockw...

Страница 14: ..._______________________________________________________________________________________ Extraordinary maintenance log Extraordinary maintenance The table below is used to note any extraordinary mainte...

Страница 15: ...______________________________________________________________________ DISMANTLING AND DISPOSAL CAME S p A implements an EN ISO 14001 certified and compliant Environmental Management System at its pla...

Страница 16: ...dienst bei ES Por cualquier informaci n sobre la empresa los productos y asistencia en su idioma NL Voor meer informatie over het bedrijf de producten en hulp in uw eigen taal PT Para toda e qualquer...

Отзывы: