21
MENU DESCRIPTIONS
MAIN MENU
SUB MENU
DESCRIPTION
LANGUAGE
The language menu determines the language for the menu. Factory default is Italian.
English
Select for English
Francais
Select for French
Deutsch
Select for German
Espanol
Select for Spanish
Italiano
Select for Italian
FUNCTIONS
The functions menu determines how your operator will function.
AutoClose
Automatic Close:
Activates or deactivates the automatic close timer (ACT). The automatic close timer (ACT) activates at each opening
endpoint. The time may be adjusted, and is dependent on any entrapment protection devices that may activate; and it does not activate after
a total safety “stop” or during a power outage.
Maintained Act
Maintained Action:
The gate works by constant pressure to open (button 2-3) and constant pressure to close (button 2-4) or if set to the
“On Closing” function, only button 2-4. (Remote Control functionality is disabled).
Obstacle Det.
Obstacle Detected:
When motor is stopped (gate closed or after a total stop command) it prevents any movement if an entrapment
protection devices, such as the photoelectric sensors, detect an obstacle.
Safety Test
Safety Test:
Allows the electronic card to check the efficiency of any entrapment protection devices (i.e. photoelectric sensors) after every
open or close command.
Preflashing
Pre-Flashing:
After an opening or closing command, the flashing light, connected to 10-5, starts flashing before the gate begins to
run. Pre-flashing can be enabled using the FUNCTIONS menu and the timing period can be set using the TIMING ADJ menu, however,
when the gate is closed and pre-flashing is enabled the opening will be delayed for the duration of the pre-flashing period but the
light will not start flashing until the gate starts moving.
Ram hit funct.
Ram Blow:
Before opening the gate(s) will press onto the mechanical endstop for a few seconds, to help release the electrolock (to set the
time, see “Ram timing” in the Adjust Timings menu).
Total Stop
Total Stop:
This function stops the gate and consequently excludes any automatic closing cycle; for movement to Resume, you need
to use the keypad or remote control. Insert entrapment protection device on [1-2] if used, select “Deactivated” if unused.
CX Input
CX Input:
The N.C. safety contact input can take on the following functions: C1 (re-opening when closing), C2 (re-closing when
opening), C3 (partial stop), C4 (obstacle stall), C7 (re-opening when closing, for sensitive edges), C8 (re-closing when opening, for
sensitive edges) or, be deactivated. Refer to entrapment protection devices.
CY Input
CY Input:
Safety contact input can take on the following functions: C1 (re-opening when closing), C2 (re-closing when opening), C3
(partial stop), C4 (obstacle stall), C7 (re-opening when closing, for sensitive edges), C8 (re-closing when opening, for sensitive edges)
or, be deactivated. Refer to entrapment protection devices.
CZ Input
CZ Input:
Safety contact input can take on the following functions: C1 (re-opening when closing), C2 (re-closing when opening), C3
(partial stop), C4 (obstacle stall), C7 (re-opening when closing, for sensitive edges), C8 (re-closing when opening, for sensitive edges)
or, be deactivated. Refer to entrapment protection devices.
CI. Thrust
Closing thrust:
At the endpoint stage during closing, the gearmotors perform a final closing-thrust of the doors for a few seconds.
Lock
Lock:
To lock the gate(s).
Config.
Configuration:
- Encoder: Managing decelerations, obstacle detection and sensitivity
(default function)
: (AX3024U, AX5024U, FROG-A24E, A1824U, FROG-
JU, F7024E)
- Slow run: Decelerations when opening and closing.
- Fcap-RallCh.: End stop when opening and deceleration when closing.
- Time of Run: Timed end stop.
- Limit switch (endstop): Opening and closing endstop.
endstop
Endstop:
Configure the endpoints are normally closed or open contacts.
NOTE:
This function appears only if selected from the “Config.”
function in the FUNCTIONS menu.
cmd 2-7
Command 2-7:
Setting the 2-7 contact to step-by- step mode (open-close) or sequential (open-stop-close-stop).
cmd 2-3P
Command 2-3P
:
Setting the 2-3P contact to opening (second gate opens fully) or partial (second gate opens partially depending on
the time set on “Partial opening” from the Adjust Times menu).
MENU DESCRIPTIONS
The menu is used to configure the operator based on your application and the devices that are connected to the operator.
NOTE:
The encoder menu only appears if "Config." is selected from the "Functions" menu.
PROGRAMMING