background image

ZT6: 

SAFETY

C1   

REOPENING DURING CLOSING

•  When the automation is in its closing cycle and the safety circuit is triggered the automation will stop and reverse its motion until it reaches its 

fully open position again.

•  If the auto closing option is enabled and the safety is no longer triggered the auto closing countdown will commence, once completed the 

automation will start the closing cycle again.

•  If the auto closing option is not enabled the automation will return to the fully open position awaiting another activation from a command device.

FUNCTIONS > C1 Input, CX Input

SAFETY INPUTS

C2  

RECLOSING DURING OPENING

•  When the automation is in its opening cycle and the safety circuit is triggered the automation will stop and reverse its motion until it reaches its 

fully closed position again.

•  Once the automation has reached the fully closed position it will require another activation from a command device to restart.

C3  

PARTIAL STOP

•  When the automation is in its opening cycle and the safety circuit is triggered the automation will stop.

•  If the auto closing option is enabled and the safety is no longer triggered the auto closing countdown will commence, once completed the 

automation will start closing the device.

If during the reverse motion a diff erent safety is triggered the automation will perform the appropriate action for the new triggered 

safety, should multiple safeties be triggered at the same time the automation will be halted at its current position.

OR

The above sequence will be attempted 3 times before the automation is halted, the automation will then 

require activation from a command device to restart.

Содержание BY-3500T

Страница 1: ...CAME COM UK BY 3500T kit Complete kit for a sliding gate weighing up to 3500kg max width 23m QUICK SETUP GUIDE TO BE READ IN CONJUNCTION WITH THE FULL INSTRUCTION MANUAL ...

Страница 2: ...Pair of Photocells top a433n Tuned Antenna topd4Fks Fixed code Transmitter 1 Kit Contents 2 Safety Instructions 3 Typical Gate Setup 4 Geometry 5 Manual Release Instructions 6 Kit Wiring Diagram 7 Control Panel Quick Start Guide 8 Control Panel Programming Transmitters 9 Control Panel Safety 10 Optional Accessories ...

Страница 3: ...ssing through the gate Keep feet away from the bottom of the gate during operation Do not operate the gate by remote control unless they are in view Do not attempt to block or interfere with the gate movement during operation Under no circumstances should you attempt to modify the gate automation system Ensure that your gate is serviced at 3 to 12 month intervals dependent on number of openings by...

Страница 4: ... 4 6 OUTSIDE OF GATES INSIDE OF GATES 10 11 12 B Y 3 5 0 0 T 1 BY 3500T Motor 5 Selector Keypad optional 9 Photocell column optional accessory 2 Limit switch fins 6 Photocells on outside of gate posts 10 Slide guides 3 Reception Antenna 7 2nd set of Photocells optional 11 Rack 4 Flashing Light optional 8 Mechanical End Stop not supplied 12 Sensitive safety edge CONTROL PANEL The control panel is i...

Страница 5: ... gearmotor to the accessories 5 Prepare a Ø 20 mm tube to run the release cord through A 6 Use Ø 40 mm corrugated tubes to connect the gearmotor to the accessories The number of tubes depends on the type of system and the accessories that are going to be fitted INSTALLATION Please refer to the full manual for installing the motor rack and setting travel end points 1 2mm The rack and pinion should ...

Страница 6: ...casing and lock back in place B2 6 Attempt to manually move the gate to ensure it is fully engaged The BY 3500T sliding gate operator has a manual release system inside the metal casing Basic Maintenance Hints Tips If a ground track is fitted ensure the track is always clear of debris Lubricate manual release compartment and key mechanism Manually release the gates at least once per month ALWAYS i...

Страница 7: ...ble length RX 4 Core 0 5mm Flex TX 4 Core 0 5mm Flex 1m 30m AF43S Plug in 10 2 TX C NC TX 2 TX TOP A433N Antenna Cable length RG58 Max 5m RX Mains Supply 400V 3 Phase Cable length 1m 10m H05RN F 4G x 1 5mm2 10m 20m H05RN F 4G x 2 5mm2 20m 30m H05RN F 4G x 4mm2 ...

Страница 8: ... stop Dip switch 10 ON 3 Disable the safety input C1 Dip switch 7 ON 4 Disable safety input CX Dip switch 8 ON 5 Set all other dip switches off 6 Set the motor direction as viewed from the inside of the property looking out The default setting for the motor is left hand opening if the gate is to open to the right the motor and end stop connections must be swapped as below Right hand opening 7 With...

Страница 9: ...e one that was saved to the control board in the above procedure Using a transmitter that has not been saved on to the control board 1 Press and hold the two large buttons on the remote until the LED at the top starts flashing rapidly Release the buttons 2 Now press and release the button you wish to use to open the gate The LED will change to a slow flash 3 Place the previously programmed transmitt...

Страница 10: ...ill stop and reverse its motion until it reaches its fully closed position again Once the automation has reached the fully closed position it will require another activation from a command device to restart C3 PARTIAL STOP When the automation is in its opening cycle and the safety circuit is triggered the automation will stop If the auto closing option is enabled and the safety is no longer trigge...

Страница 11: ...our 806SL 0250 SELB1SDG3 Surface mounted with blue backlighting for 250 users RAL7024 Grey colour HARDWIRED KEYPAD SELECTORS 806SL 0280 SELT1BDG Surface mounted 12 button Bus keypad with blue backlighting RAL7024 Grey colour 806SL 0290 SELT2BDG Flush mounted 12 button Bus keypad with blue backlighting RAL7024 Grey colour 806SL 0370 S0002P External two channel 12 24 V AC DC IP54 control card for ke...

Страница 12: ... THIS DOCUMENT AT ANY TIME THE DATA AND INFORMATION SHOWN IN THIS CATALOGUE ARE SUBJECT TO CHANGE WITHOUT OBLIGATION TO GIVE PRIOR NOTICE BY CAME S P A E OE CAME BPT North Unit 1B Sills Road Willow Farm Business Park Castle Donington DE74 2US Tel 0115 921 0430 CAME BPT South Liberta House Maxted Road Maylands Ind Est Hemel Hempstead Herts HP2 7DX Tel 01442 230 800 CAME BPT Ireland Unit 9 The Westw...

Отзывы: