ZT6:
QUICK START GUIDE
Should the gates not operate as suggested above,
call CAME helpline
0115 921 0430
for technical support.
Safety inputs should now be configured and the
gate force tested as required. Please refer to the
full manual to complete the commissioning.
Ensure the wiring is complete (refer to the wiring diagram) & any required physical stops are set before
commencing with programming
Tick
1. Power on the control panel.
2. Disable total stop – Dip switch
10 ON
.
3. Disable the safety input C1 – Dip switch
7 ON
.
4. Disable safety input CX – Dip switch
8 ON
.
5. Set all other dip switches off.
6. Set the motor direction as viewed from the inside of the property looking out.
The default setting for the motor is left hand opening if the gate is to open to the right the motor and end stop
connections must be swapped as below.
Right hand opening.
7. With the gate in the closed position check the gate operation by pulsing across connections 2 & 3,
the gate will open.
Please refer to the main manual for:
Changing automatic closing time, adjusting encoder settings if required
Important!
BY 3500T
M