p.
22
- M
an
ua
l
FA
01
006
-E
N
- 0
1/
20
18 - © C
AM
E S
.p
.A
. - T
ra
ns
la
te
d o
rig
in
al i
ns
tru
ct
io
ns
F66
Wireless input
RIOED8WS
[T2]
Wireless safety device (RIOED8WS) associated to a function of choice among those
available: P0 = TOTAL STOP, P7 = reopening during closing, P8 = reclosing during
opening.
For programming, see the instructions that come with the accessory.
This function only appears if the RIOCN8WS card is plugged into the control board.
OFF
= Deactivated (
default
) /
P0
/
P7
/
P8
F67 Wireless input
RIOPH8WS [T1]
RIOPH8WS is associated to any function chosen among those available: P1 = reopening
during closing; P2 = reclosing during opening; P3 = partial stop; P4 = obstruction wait.
For programming, see the instructions that come with the accessory.
This function only appears if the RIOCN8WS card is plugged into the control board.
OFF
= Deactivated /
P1
(
default
) /
P2 marked areas
/
P3
/
P4
F68 Wireless input
RIOPH8WS [T2]
RIOPH8WS is associated to any function chosen among those available: P1 = reopening
during closing; P2 = reclosing during opening; P3 = partial stop; P4 = obstruction wait.
For programming, see the instructions that come with the accessory.
This function only appears if the RIOCN8WS card is plugged into the control board.
OFF
= Deactivated /
P1
(
default
) /
P2 marked areas
/
P3
/
P4
F71 Partial opening
time
After an opening command from the button connected to 2-3P, the gate opens for an
adjustable time of between five seconds and 40 seconds.
This function only appears if the Encoder function is deactivated.
5
= 5 seconds /... /
40
= 40 seconds
U1 Entering users
Entering up to 250 users and associating to each one a function of choice among those
included. This must be done via transmitter or other control device (see "ENTERING
USERS WITH ASSOCIATED COMMAND paragraph).
1
= Step-step command (open-close) /
2
= Sequential command (open-stop-close-
stop) /
3
= Open only command /
4 = partial command
U2 Deleting users
Deleting a single user
OFF
= Deactivated /
ON
= Activated
U3 Deleting users
Deleting all users.
0
= Deactivated (
default
) /
1
= Delete
U4
Decoding the
radio-frequen-
cy code
Select the type of transmitter radio coding that you wish to save on the control board.
⚠
When you select a radio coding, all saved transmitter are automatically deleted.
TWIN's coding lets you save multiple users with the same key (Key block).
1 = all series ( default
) /
2 = only Rolling Code series /3 = only TWIN series
A1 Motor type
To set the gearmotor depending on the gate's weight.
1 = 400 kg /2
= 600 kg /
3
= 800 kg /
4
= 1000 kg
A3 Gate-swing
calibration
Automatic calibration of the gate-leaf swing (see the CALIBRATING SWING paragraph).
OFF
= Deactivated /
ON
= Activated
A4 Resetting
parameters
Caution! The default settings are restored and the travel calibration deleted.
OFF
= Deactivated /
ON
= Activated
A5 Maneuver
count
For viewing the number of maneuvers completed or for
deleting
them (001 =
100
maneuvers; 010 =
1000
maneuvers; maneuvers;
999
= 99900 maneuvers;
CSI
=
maintenance job).
A6 Adjusting the
motor torque
For adjusting the motor torque from 1 (minimum) to 5 (maximum).
1
/
2
/
3
/
4
/
5
H1 Version