F8 Command
[2-3P]
From the control device connected to 2-3P, it performs a partial (1) or total opening (2)
of the gate.
The partial opening time is adjusted on function F 71.
1 = Partial opening /
2
= Open
F9
Obstruction
detection with
motor stopped
With the gate closed, opened or totally stopped, the gearmotor stays idle if the safety
devices, that is, photocells or sensitive safety-edges detect an obstruction.
OFF
= Deactivated (
default
) /
ON
= Activated
F10 Gate open si-
gnaling output
It signals the gate status. The signal device is connected to contact 10-5.
0 = lit when gate is open or moving (default
) /
1 = during openings it flashes
intermittently each half second, and during closings it flashes intermittently
each second.
It stays on steadily when the barrier is open, off or when it s closed.
F11 Encoder
Managing slow-downs, obstruction detections and sensitivity.
OFF
= Deactivated /
ON
= Activated (
default
)
F12 Soft Start
With each opening and closing command, the gate starts moving slowly for a few
seconds.
OFF
= Deactivated (
default
) / ON = Activated
F14 Sensor type
selection
Setting the type of accessory for controlling the operator.
0
= command with transponder sensor or magnetic card reader /
1
= command with
keypad selector (
default
).
F18 Additional light
Output on contact 10-E.
Flashing light: it flashes during the gate's opening and closing phases.
Cycle: outdoor lamp for extra lighting in the driveway. It stays lit from when the gate
starts opening to when it closes, including the waiting time prior to automatic closing
(only with with TCA activated).
0
= Flashing light (default)
/
1 =
Cycle
F19 Automatic
Closing Time
The automatic-closing wait starts when the opening limit switch point is reached and
can be set to between 1 and 180 seconds. The automatic closing does not work if any
of the safety devices trigger when an obstruction is detected, or after a total stop, or
during a power outage.
OFF
= Deactivated (
default
) /
1 =
1
180
= 180 seconds
F20
Automatic
closing time
after partial
opening
The wait before the automatic closing starts after a partial opening command for an
adjustable time of between 1 s and 180 s.
The automatic closing does not work if any of the safety devices trigger when an
obstruction is detected, or after a total stop, or during a power outage.
The F19 function must not be activated.
OFF
= Deactivated /
1 =
1
10
= seconds (
default
) / … /
180
= 180 seconds
F21 Pre-flashing
time
Adjusting the pre-flashing time for the flashing light connected to 10-E before each
maneuver. The flashing time is adjustable from one to ten seconds.
OFF
= Deactivated (
default
) /
1
= 1 seconds / … /
10
= 10 seconds
F28 Gate travel
speed
Setting the gate's opening and closing speeds, calculated as a percentage.
60
= Minimum speed / … /
100
= Maximum speed (
default
)
F30 Slow-down
speed
Setting the gate's opening and closing slow-down speed, calculated as a percentage.
10
= Minimum speed / … /
50
= Maximum speed (
default
)
F34 Travel sensi-
tivity
Adjusting obstruction detection sensitivity during gate-leaf travel.
10
= maximum sensitivity / … /
100
= minimum sensitivity (
default
)