F35 Slow-down
sensitivity
Adjusting obstruction detection sensitivity during slow-down.
10
= maximum sensitivity / … /
100
= minimum sensitivity (
default
)
F36 Adjusting the
partial opening
Adjustment as a percentage of total travel, during gate opening.
This function appears only is the Encoder function is activated.
10
= 10% of the gate travel (
default
) / … /
80
= 80% of the door travel
F37 Opening slow-
down point
Percentage adjustment of the total door travel, of the opening slow-down starting point.
This function appears only is the Encoder function is activated.
10
= 10% of the gate-leaf travel / … /
25
= 25% of the gate-leaf travel (
default
) / …
/
60
= 60% of the gate-leaf travel
F38 Closing slow-
down point
Percentage adjustment of the total door travel, from the closing slow-down starting
point.
This function appears only is the Encoder function is activated.
10
= 10% of the gate-leaf travel / … /
25
= 25% of the gate-leaf travel (
default
) / …
/
60
= 60% of the gate-leaf travel
F49
Managing
the serial
connection
To enable the paired operating mode or the CRP (Came Remote Protocol).
0
= Deactivated (
default
) /
1
= Paired /
3
= CRP
F50 Saving data
Saving users and settings saved in the Memory Roll.
This function only appears if a Memory Roll has been plugged into the control
board.
0
= Deactivated (
default
) /
1
= Activated
F51 Reading of
data
Uploading data saved in the Memory Roll.
This function only appears if a Memory Roll has been plugged into the control
board.
0
= Deactivated (
default
) /
1
= Activated
F52
Transferring
parameters in
paired mode
Uploading settings from Master to Slave.
This appears only if function F49 is set to Paired.
OFF
= Deactivated (
default
) /
ON
= Activated
F54 Opening
direction
For setting the gate opening direction.
OFF
= Opening left (
default
) /
ON
= Opening right
F56 Peripheral
number
To set the peripheral's number from 1 to 255 for each control board when you have a
system with several operators.
1 ----> 255
F63 Changing COM
speed
For setting the communication speed used in the CRP (Came Remote Protocol)
connection system.
0
= 1200 Baud /
1
= 2400 Baud /
2
= 4800 Baud /
3
= 9600 Baud /
4
= 14400 Baud
/
5
= 19200 Baud /
6
= 38400 Baud (
default
) /
7
= 57600 Baud /
8
= 115200 Baud
F65 Wireless input
RIOED8WS [T1]
Wireless safety device (RIOED8WS) associated to a function of choice among those
available: P0 = TOTAL STOP, P7 = reopening during closing, P8 = reclosing during
opening.
For programming, see the instructions that come with the accessory.
This function only appears if the RIOCN8WS card is plugged into the control board.
OFF
= Deactivated (
default
) /
P0
/
P7
/
P8