Danger of high voltage;
Danger of crushing;
Danger of foot crushing;
Danger of hand entrapment;
Do not transit through during maneuvering.
you have set up a suitable dual pole cut off device along the power supply that is compliant
with the installation rules. It should completely cut off the power supply according to category
III surcharge conditions. • All opening controls must be installed at least 1.85 m from the
perimeter of the gate's working area, or where they cannot be reached from outside the gate.
• All switches in maintained action mode must be positioned so that the moving gates leaves,
the transit areas and vehicle thru-ways are completely visible, and yet the switches must be
also away from any moving parts • Unless the action is key operated, the control devices
must be fitted at, at least, 1.5 m from the ground and must not be accessible to the public.
• To pass the collision force test use a suitable sensitive safety-edge. Install it properly and
adjust as needed. • Before handing over to users, check that the system is compliant with
the 2006/42/CE uniformed Machinery Directive. Make sure the settings on the operator are
all suitable and that any safety and protection devices, and also the manual release, work
properly. • Affix a permanent tag, that describes how to use the manual release mechanism,
close to the mechanism. • Make sure to hand over to the end user, all operating manuals for
the products that make up the final machinery.