6.1 Technical description board ZBX241

1 – Power supply connection terminal board and transformer
2 - 1A line fuse
3 - 1.6A accessory fuse
4 - “Function selection” dip-switch
5 - Radiofrequency board slot
6 - TCA trimmer: automatic closing time adjustment
7 - AP.PARZ. trimmer: partial aperture adjustment
8 - SENS. trimmer: amperometric sensitivity adjustment

9 - Code memorising key
10 - LED indicator for radio codes
11 - BN1 board connecting terminal board
12 - Emergency battery connecting terminal board
13 - 10A motor fuse
14 - 630mA control unit fuse
15 – Power supply LED indicator
16 - Motor, end-stop and accessory connecting terminal board

4

7

6

8

13

3

14

9

5

15

10

1

11

12

2

6.2  ZBX241  main components

16

            

8

            

A

ll t

h

e d

at

a a

n

d i

n

fo

rm

at

io

n c

o

n

ta

in

ed h

er

ei

n i

s c

o

n

si

d

er

ed s

u

b

je

ct to c

h

an

g

e a

t a

n

y t

im

e a

n

d a

t o

u

r d

is

cr

et

io

n

ENGLISH

6 Control board

This control board is powered by 230V a.c. across terminals L1 and L2, and is protected by a 1A fuse on the main power line. 
Control systems are powered by low voltage and protected with by a 1.6A fuse.
The total power consumption of 24V accessories must not exceed 40 W.
Fixed operating time of 90 seconds.
Photocells can be connected to obtain:
- Re-opening during the closing cycle;
- Partial stop: shutdown of moving gate, with activation of an automatic closing cycle;
- Total stop: shutdown of gate movement without automatic closing; a pushbutton or radio remote control must be actuated to 
resume move ment;
The board, moreover, integrates and independently runs a safety function capable of detecting obstacles that hinder movement:
during opening: the gate stops and the automatic closure is activated;
during closure: the gate inverts its direction until it is completely open, after which it closes automatically. 
   

Warning! after three consecutive inversions, the gate will remain open and automatic closure will be discontinued. Toclose 

the gate, use the radio remote control or the push-button.
Other functions available:
   Automatic closing:  The automatic closing timer is automatically activated at the end of the opening cycle.  The preset, adjustable 
automatic closing time is automatically interrupted by the activation of any safety system, and is deactivated after a total stop 
command or in case of power failure;
- Partial opening function: opening of the gate to the desired position for pedestrian passage, which can be adjusted on the 
trimmer;
-  Detection of obstacles: this function cancels every command if the photocells (in whatever safety function connected) detect 
an obstacle with the gate at the  limit position;
-  “Human presence” opera tion;
-  Flashing light activated before opening and closing cycle begins;
-  Selection of command sequence: open-close-reverse, open-stop-close-stop or open only.
Adjustments: automatic closing time, partial opening time and amperometric sensitivity.

         IMPORTANT:- the opening of the unblock panel arrests the motor. 
 

 

- Shut off the mains power and disconnect the batteries before servicing the inside of the unit.

Содержание BX241

Страница 1: ...AUTOMATION SYSTEM FOR SLIDING GATES BX241 INSTALLATION MANUAL ...

Страница 2: ... to set up and upkeep 4 Description 2 1 Destination The following standard were complied with for this product EN 12978 UNI EN 954 1 CEI EN 60335 1 UNI EN 12453 The BX 241 ratiomotor is for the automation of sliding residential gates even in cases of intense traffic The use of this product for purposes other than the one intended and installation carried out in a manner other than as instructed in...

Страница 3: ...board 5 BN1 battery charger board 6 Electric board front cover 7 Release door 8 Base plate 9 Securing screws 10 Plates for securing screws 11 Nuts ACCESSORIES 1 R001 Cylinder lock with DIN keys 2 BSF Braking device 3 BRC Cable winding device 4 B4337 Chain transmission device 5 CCT Simple 1 2 chain 6 CGIU 1 2 chain joint 7 CGZ Galvanized steel 22 x 22 module 4 rack 8 CGZF PA 6 nylon 20 x 32 module ...

Страница 4: ... Make sure all tools and materials necessary are within reach to install the edge in maximum safety according to regulations in force The following figure illustrates the minimum equipment for the installer N B An evaluation of the size of the cables with lengths other than the data in the table must be made based on the effective absorption of the connected devices according to the instructions i...

Страница 5: ...on ENGLISH Install the screws in the anchor plate and fasten them with a nut then bend the preformed clamps downwards Construct a cement foundation that is large enough to accomodate the gear motor it is a good idea to protrude 50 mm from the ground When pouring the foundation embed the gear motor anchor plate and the relative clamps in the cement The anchor bolts should be embedded in the concret...

Страница 6: ... steel feet for vertical adjustment and levelling plates and bolts for anchorage to the base 5 5 Unit installation 5 6 Attaching the rack limit Attach the rack to the gate as described below Release the gearmotor parag 5 8 position the rack on the pinion of the gearmotor and slide the gate manually in order to attach the rack along its entire length when the rack is attached to the gate adjust the...

Страница 7: ...bs whose positions determine the limits of gate travel on the rack Note do not allow the gate to strike the mechanical stops in the open or closed positions 5 8 Gear release To open the access door insert the key push down and rotate clockwise Now release the gear motor by rotating the knob in the direction shown BLOCK RELEASE ATTENTION the opening of the unblock panel arrests the motor ...

Страница 8: ...ycle Total stop shutdown of gate movement without automatic closing a pushbutton or radio remote control must be actuated to resume movement The board moreover integrates and independently runs a safety function capable of detecting obstacles that hinder movement during opening the gate stops and the automatic closure is activated during closure the gate inverts its direction until it is completel...

Страница 9: ...t switch unit 24V d c single phase motor Limit switch unit The motor and limit switch unit are wired at the factory for mounting on the left hand side of the gate as seen from the inside If right hand installation is desired invert limit switch connections FA FC on the terminal block invert motor phase connections M N on the terminal block 24V d c single phase motor Insert batteries in the appropr...

Страница 10: ...er supply 24V d c motor 24V output in motion e g flashing light 25W 24V powering accessories max 40W Pushbutton stop N C Pushbutton partial opening N O Contact radio and or pushbutton for controlled see dip switch 2 3 Contact N C for re aperture during closure 24V 3W max gate opened signal lamp Contact N C for partial stop Connection limit switch opens Connection limit switch closes Antenna connec...

Страница 11: ...ate safety device 2 C3 if not set the dipswitch to ON 10 Not used ON OFF T P A T P A T A C T A C SENS SENS 42 2 42 2 4 0 0 6 44 29 4 3 3 02 2 11 All the data and information contained herein is considered subject to change at any time and at our discretion ENGLISH 2 The AF board should ALWAYS be inserted when the power is off 1 On AM transmitters operating at 433 92 MHz TOP and TAM series position...

Страница 12: ...r channels 1 and 2 as per fig A see fig B for any subsequent settings on different channels TOP T262M T302M FIG A FIG B P1 CH1 P2 CH2 P1 CH1 P2 CH3 P1 CH3 P2 CH2 P1 CH1 P2 CH4 P1 CH3 P2 CH4 Standard encoding procedure T262M T264M T2622M T302M T304M T3022M 1 assign a code also on file 2 connect encoding jumper J 3 register code 4 disinserire jumper J Press P1 or P2 in sequence in order to register ...

Страница 13: ...T432SA T434MA T432NA T434NA TAM T432 T434 T438 TAM432SA TFM T132 T134 T138 T152 T154 T158 CAME 0 0 0 0 T264M T304M 0 0 0 0 0 0 T2622M T3022M P1 CH1 P2 CH2 P3 CH3 P4 CH4 1 Code P1 CH1 P2 CH2 2 Code P3 CH1 P4 CH2 set the code to dip switch C and channel to D P1 CH1 and P2 CH2 default setting set code only P1 CH1 P2 CH2 P3 CH3 P4 CH4 see instructions on pack see instruction sheet inside the pack see ...

Страница 14: ... PROGRAM CH1 Flashing LED Lit LED CH1 FC F M FA N T P A 10 11 E1 1 2 3 3P C1 C3 7 24V AC L1T L2T L1 L2 BATTERY D C B A T A C SENS PROGRAM CH1 TCH 4024 TCH 4048 TOUCH SERIES see instruction sheet inside the pack of AF43SR circuit card see instructions on pack 1 Keep the CH1 key pressed on the base card the signal LED will flash 2 Press a transmitter key to send the code the LED will remain lighted ...

Страница 15: ...nies for proper disposal Prior to disposal it is always advisable to check specific regulations in force in the place of disposal PLEASE DISPOSE OF PROPERLY 10 Manufacturer s warranty MANUFACTURER S DECLARATION As per Enclosure II B of Machinery Directive 98 37 CE Enclosed with the technical documentation the original copy of the Declaration is available on request Date of the present declaration ...

Страница 16: ...CAME UNITED KINGDOM LTD UNIT 3 ORCHARD BUSINESS PARK TOWN STREET SANDIACRE NOTTINGHAM NG10 5BP U K Tel 0044 115 9210430 Fax 0044 115 9210431 Cod 119BS30 ver 3 1 09 05 CAME CANCELLI AUTOMATICI ...

Отзывы: