The unit does not require specifi c maintenance. Only as a precautionary measure and in case of intensive use, we re-

commend periodic checks (every 6 months) on the state of the electric wire connected to the motor, the tightness of the nuts and 
the proper oiling of the sliding points between fi xed and mobile parts.

All checks must be recorded (in a dedicated record-book).

8 Maintenance

9 Demolition and disposal

 

 

In its premises, CAME CANCELLI AUTOMATICI S.p.A. implements an Environmental Management System certifi ed in 

compliance with the UNI EN ISO 14001 standard to ensure environmental protection.

Please continue our efforts to protect the environment—which CAME considers one of the cardinal elements in the development 
of its operational and market strategies—simply by observing brief recommendations as regards disposal:

 

DISPOSAL OF PACKAGING – The packaging components (cardboard, plastic, etc.) are all classifi able as solid urban waste 

products and may be disposed of easily, keeping in mind recycling possibilities.
Prior to disposal, it is always advisable to check specifi c regulations in force in the place of installation.

PLEASE DISPOSE OF PROPERLY!

 

PRODUCT DISPOSAL – Our products are made up of various types of materials. Most of them (aluminium, plastics, iron, 

electrical wires, etc.) may be disposed of in normal garbage collection bins and can be recycled by disposing of in specifi c re-
cyclable material collection bins and disposal in authorized centres. Other components (electrical boards, remote control batteries, 
etc.), however, may contain polluting substances. They should therefore be removed and given to qualifi ed service companies for 
proper disposal.
Prior to disposal, it is always advisable to check specifi c regulations in force in the place of disposal.

PLEASE DISPOSE OF PROPERLY!

10 Manufacturer’s warranty

MANUFACTURER’S

 

DECLARATION

As per Enclosure II B of Machinery Directive 98/37/CE

Enclosed with the technical documentation (the original copy of the Declaration is available on request)

Date of the present declaration 07/12/2001

The representatives of

CAME Cancelli Automatici S.p.A.
via Martiri della Libertà, 15
31030Dosson di Casier - Treviso - ITALYtel 
(+39) 0422 4940 - fax (+39) 0422 4941
internet: www.came.it - e-mail: [email protected] 

Hereby declare, under their own respons ibility, that the product/s called ...

… comply with the Italian National Legal Provisions that transpose the 
following Community Directives (where specifi cally applicable):

M

ACHINERY

 D

IRECTIVE

 98/37/CE

L

OW

 V

OLTAGE

 D

IRECTIVE

 73/23/EEC - 93/68/EEC

L

ECTROMAGNETIC

 C

OMPATIBILITY

 D

IRECTIVE

 89/336/EEC - 92/31/EEC

R&TTE D

IRECTIVE

 1999/5/CE

Also, they furthermore represent and warrant that the product/s that are the subject of the present Declaration 
are manufactured in the respect of the following main harmonized provisions:

EN 292 

PART

 1 

AND

 2 

M

ACHINERY

 

SAFETY

.

EN 12453 

 

I

NDUSTRIAL

COMMERCIAL

 

AND

 

OTHER

 

CLOSING

 

MECHANISMS

.

EN 12445 

 

I

NDUSTRIAL

COMMERCIAL

 

AND

 

OTHER

 

CLOSING

 

MECHANISMS

.

EN 12978 

 

S

AFETY

 

DEVICES

 

FOR

 

POWER

 

OPERATED

 

DOORS

 

AND

 

GATES

 ....

EN 60335 - 1   

S

AFETY

 

IN

 

APPARATUSES

 

FOR

 

HOME

 

USE

.

EN 60204 - 1   

M

ACHINERY

 

SAFETY

.

EN 61000 - 6 - 2 

E

LECTROMAGNETIC

 C

OMPATIBILITY

.

EN 61000 - 4 - 4 

E

LECTROMAGNETIC

 C

OMPATIBILITY

EN 61000 - 4 - 5 

E

LECTROMAGNETIC

 C

OMPATIBILITY

IMPORTANT CAUTION!
It is forbidden to market/use product/s that are the subject of this declaration before completing and/or 
incorporating them in total compliance with the provisions of Machinery Directive 98/37/CE

Signatures of the Representatives

TECHNICAL MANAGER 

Mr. Gianni Michielan

MANAGING DIRECTOR

Mr. Paolo Menuzzo

BX241

R001 - BSF - BRC5 - BRC10 - BRC15 - B4337 - CGZ

CGZF - CGZS - CCT 

Содержание BX241

Страница 1: ...AUTOMATION SYSTEM FOR SLIDING GATES BX241 INSTALLATION MANUAL ...

Страница 2: ... to set up and upkeep 4 Description 2 1 Destination The following standard were complied with for this product EN 12978 UNI EN 954 1 CEI EN 60335 1 UNI EN 12453 The BX 241 ratiomotor is for the automation of sliding residential gates even in cases of intense traffic The use of this product for purposes other than the one intended and installation carried out in a manner other than as instructed in...

Страница 3: ...board 5 BN1 battery charger board 6 Electric board front cover 7 Release door 8 Base plate 9 Securing screws 10 Plates for securing screws 11 Nuts ACCESSORIES 1 R001 Cylinder lock with DIN keys 2 BSF Braking device 3 BRC Cable winding device 4 B4337 Chain transmission device 5 CCT Simple 1 2 chain 6 CGIU 1 2 chain joint 7 CGZ Galvanized steel 22 x 22 module 4 rack 8 CGZF PA 6 nylon 20 x 32 module ...

Страница 4: ... Make sure all tools and materials necessary are within reach to install the edge in maximum safety according to regulations in force The following figure illustrates the minimum equipment for the installer N B An evaluation of the size of the cables with lengths other than the data in the table must be made based on the effective absorption of the connected devices according to the instructions i...

Страница 5: ...on ENGLISH Install the screws in the anchor plate and fasten them with a nut then bend the preformed clamps downwards Construct a cement foundation that is large enough to accomodate the gear motor it is a good idea to protrude 50 mm from the ground When pouring the foundation embed the gear motor anchor plate and the relative clamps in the cement The anchor bolts should be embedded in the concret...

Страница 6: ... steel feet for vertical adjustment and levelling plates and bolts for anchorage to the base 5 5 Unit installation 5 6 Attaching the rack limit Attach the rack to the gate as described below Release the gearmotor parag 5 8 position the rack on the pinion of the gearmotor and slide the gate manually in order to attach the rack along its entire length when the rack is attached to the gate adjust the...

Страница 7: ...bs whose positions determine the limits of gate travel on the rack Note do not allow the gate to strike the mechanical stops in the open or closed positions 5 8 Gear release To open the access door insert the key push down and rotate clockwise Now release the gear motor by rotating the knob in the direction shown BLOCK RELEASE ATTENTION the opening of the unblock panel arrests the motor ...

Страница 8: ...ycle Total stop shutdown of gate movement without automatic closing a pushbutton or radio remote control must be actuated to resume movement The board moreover integrates and independently runs a safety function capable of detecting obstacles that hinder movement during opening the gate stops and the automatic closure is activated during closure the gate inverts its direction until it is completel...

Страница 9: ...t switch unit 24V d c single phase motor Limit switch unit The motor and limit switch unit are wired at the factory for mounting on the left hand side of the gate as seen from the inside If right hand installation is desired invert limit switch connections FA FC on the terminal block invert motor phase connections M N on the terminal block 24V d c single phase motor Insert batteries in the appropr...

Страница 10: ...er supply 24V d c motor 24V output in motion e g flashing light 25W 24V powering accessories max 40W Pushbutton stop N C Pushbutton partial opening N O Contact radio and or pushbutton for controlled see dip switch 2 3 Contact N C for re aperture during closure 24V 3W max gate opened signal lamp Contact N C for partial stop Connection limit switch opens Connection limit switch closes Antenna connec...

Страница 11: ...ate safety device 2 C3 if not set the dipswitch to ON 10 Not used ON OFF T P A T P A T A C T A C SENS SENS 42 2 42 2 4 0 0 6 44 29 4 3 3 02 2 11 All the data and information contained herein is considered subject to change at any time and at our discretion ENGLISH 2 The AF board should ALWAYS be inserted when the power is off 1 On AM transmitters operating at 433 92 MHz TOP and TAM series position...

Страница 12: ...r channels 1 and 2 as per fig A see fig B for any subsequent settings on different channels TOP T262M T302M FIG A FIG B P1 CH1 P2 CH2 P1 CH1 P2 CH3 P1 CH3 P2 CH2 P1 CH1 P2 CH4 P1 CH3 P2 CH4 Standard encoding procedure T262M T264M T2622M T302M T304M T3022M 1 assign a code also on file 2 connect encoding jumper J 3 register code 4 disinserire jumper J Press P1 or P2 in sequence in order to register ...

Страница 13: ...T432SA T434MA T432NA T434NA TAM T432 T434 T438 TAM432SA TFM T132 T134 T138 T152 T154 T158 CAME 0 0 0 0 T264M T304M 0 0 0 0 0 0 T2622M T3022M P1 CH1 P2 CH2 P3 CH3 P4 CH4 1 Code P1 CH1 P2 CH2 2 Code P3 CH1 P4 CH2 set the code to dip switch C and channel to D P1 CH1 and P2 CH2 default setting set code only P1 CH1 P2 CH2 P3 CH3 P4 CH4 see instructions on pack see instruction sheet inside the pack see ...

Страница 14: ... PROGRAM CH1 Flashing LED Lit LED CH1 FC F M FA N T P A 10 11 E1 1 2 3 3P C1 C3 7 24V AC L1T L2T L1 L2 BATTERY D C B A T A C SENS PROGRAM CH1 TCH 4024 TCH 4048 TOUCH SERIES see instruction sheet inside the pack of AF43SR circuit card see instructions on pack 1 Keep the CH1 key pressed on the base card the signal LED will flash 2 Press a transmitter key to send the code the LED will remain lighted ...

Страница 15: ...nies for proper disposal Prior to disposal it is always advisable to check specific regulations in force in the place of disposal PLEASE DISPOSE OF PROPERLY 10 Manufacturer s warranty MANUFACTURER S DECLARATION As per Enclosure II B of Machinery Directive 98 37 CE Enclosed with the technical documentation the original copy of the Declaration is available on request Date of the present declaration ...

Страница 16: ...CAME UNITED KINGDOM LTD UNIT 3 ORCHARD BUSINESS PARK TOWN STREET SANDIACRE NOTTINGHAM NG10 5BP U K Tel 0044 115 9210430 Fax 0044 115 9210431 Cod 119BS30 ver 3 1 09 05 CAME CANCELLI AUTOMATICI ...

Отзывы: