6.1 General description
6 Control board
F U S E TA B L E
To protect:
fuse:
Control board (line)
5A-F
Accessories
1A-F
Command devices
630mA-F
T E C H N I C A L I N F O R M AT I O N
Power supply
230V - 50/60 Hz
Maximum power allowed
200 W (BX74)
300 W (BX78)
Absorption at rest
2,6A (BX74)
2,4A (BX78)
Max power of 24V accessories
20 W
6.2 Main components
1 - Power supply terminals
2 - Line fuse
3 - Accessory fuse
4 - Card fuse
5 - Button for memorising the radio code
6 - Trimmer PAR.OP.: Partial opening adjustment
7 - Trimmer A.C.T.: Automatic closing time adjustment
8 - Function selector (4) DIP switch
9 - Function selector (10) DIP switch
10 - Socket for connecting the remote control’s
11 - Radio-code signalling LED indicator
12 - Accessories’ and command device’s terminals
• • • • •• • •
• • • • •• • •
AF
1 2 3 4
O N
5 6 7 8 9 1 0
1 2 3 4
O N
12
2
10
3
5
7
6
11
9
4
8
Orange
Blue
Violet
White
Red
Black
Use 230V A.C. to power the electronic card using the L-N
terminals, at a max 50/60Hz frequency.
Use 24V to power the command devices and accessories.
Careful! The accessories cannot exceed 20W of overall power.
The photocells may be set up for re- opening during closing (2-
C1), partial stop, total stop and obstacle detection when motor
is stopped.
Note: when a normally closed safety contact (i.e. 2-C1, 2-C3 or
1-2) is opened, the signalling LED starts to fl ash (ref. point 11,
main components).
The optical reader inverts the gate’s direction of travel when it
detects and obstacle during its opening and/or closing move-
ment.
Warning: after 3 obstacle detections, the gate stops when in
opening-mode and excludes automatic-closing mode; to regain
movement press the command button or use the remote control.
All connections are protected by quick-fuses – see table.
The card handles the following functions:
- Automatic closing after an opening command;
- Warning light pre-fl ashing;
- Obstacle detection when gate is still at any point;
The following command modes are possible:
- Opening/closing;
- Opening/closing in maintained action mode;
- partial opening;
- total stop.
Apposite trimmers regulate:
- The automatic closing’s running time;
- The partial opening;
Warning! Before acting on the machinery, cut off the main power
supply and disconnect any emergency batteries.
1
Pa
g.
1
0
10
- M
anu
al c
od
e:
11
9
B
U
5
6
11
9
B
U
5
6
ve
r.
1
.0
1.
0
0
1
/2
0
0
8 © C
A
M
E c
an
celli auto
mati
ci
s.p
.a. - T
h
e d
ata an
d i
nf
or
m
ati
on r
ep
orte
d i
n thi
s i
n
stall
ati
on
manu
al ar
e s
u
sc
ep
tib
le to
c
h
ang
e at an
y time an
d with
ou
t o
b
lig
ati
on
o
n C
A
M
E c
an
celli auto
mati
ci
s.p
.a. to n
otify u
se
rs.
ENGLISH