![CAME BX-78 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/came/bx-78/bx-78_installation-manual_3722570014.webp)
DIP-SWITCH 10
1 ON -
Automatic Closing
- The automatic closing timer activates at the end of the opening gate run. The pre-set time is adjustable,
and is in any case conditioned by the activation of any safety devices, and does not activate after a total safety “stop” or
during a blackout.
2 ON -
"Open-stop-close-stop"
function with [2-7] button and radio transmitter (fi tted with inserted radiofrequency card).
2 OFF -
"Open-close"
function with [2-7] button and radio transmitter ((fi tted with inserted radiofrequency card).
3 ON -
"Open only"
function with radio transmitter ((fi tted with inserted radiofrequency card).
4 ON
-
Maintained action
- The gate works by keeping button pressed (one 2-3P opening button , and one 2-7 closing button).
5 ON -
Pre-Opening and closing fl asher
- Following and opening and closing command, the fl asher connected to [W-E1], fl ashes
for 5 seconds before motion begins.
6 ON -
Obstacle detected
- When motor is stopped (gate closed or after a total stop command) it prevents any movement if safety
devices, such as photocells, detect any obstacles.
7 OFF -
Opening during closing
- If the photocells detect an obstacle during gate’s closing, gate motion is inverted until fully opened;
connect the safety device to terminals [2-C1]; if unused, set DIP switch to ON.
8 OFF -
Partial stop
- Gate stop when obstacle is detected by the safety device; once obstacle is removed, the gate remains still or
closes if automatic closing is activated. Connect the safety device to terminal [2-C3]; if unused, set the DIP switch to ON.
9 OFF -
Total stop
- This function stops the gate and then excludes any automatic closing cycle; to set in motion again, use either
the keypad or transmitter. Insert the safety device in [1-2]; If unused, set DIP switch to ON.
10 OFF Limit switch slowing activated
DIP-SWITCH 4
1 ON -
Closing only –
with command device connected on contact 2-7 (1 OFF – deactivated)
1 OFF -
Open-close –
with command device connected on 2-7 (see 10-way Dip Switch 2 of the function selector) (1 ON – deactivated).
2 ON -
Only opening –
with command device connected on contact 2-3P (2 OFF – deactivated).
2 OFF -
Partial opening –
with command device connected on contact 2-3P (2 ON – deactivated).
3 ON -
Optical reader
deactivated
; (3 OFF –activated); to program deceleration you need to activated the optical reader.
4 ON - disconnected
NOTE:
make selections when motor is stopped and in the closed position.
ON
OFF
/.
6.4 Function selector (dip-switch)
DIP-SWITCH 10
• • • • •• • •
• • • • •• • •
AF
1 2 3 4
O N
5 6 7 8 9 1 0
1 2 3 4
O N
DIP-SWITCH 4
/.
ON
OFF
Trimmer A.C.T.
=Sets the waiting time while open. Once this time has elapsed, closing automatically takes place. The waiting time
may be set from 1 to 120 seconds.
Trimmer PAR.OP.
= Sets the gate’s partial opening. By pushing the partial opening button connected at 2-3P, the gate will open for
a set time between 0 and 16 seconds.
6.5 Settings
!#4
0!2/0
• • • • •• • •
• • • • •• • •
AF
1 2 3 4
O N
5 6 7 8 9 1 0
1 2 3 4
O N
Pa
g.
1
4
14
- M
anu
al c
od
e:
11
9
B
U
5
6
11
9
B
U
5
6
ve
r.
1
.0
1.
0
0
1
/2
0
0
8 © C
A
M
E c
an
celli auto
mati
ci
s.p
.a. - T
h
e d
ata an
d i
nf
or
m
ati
on r
ep
orte
d i
n thi
s i
n
stall
ati
on
manu
al ar
e s
u
sc
ep
tib
le to
c
h
ang
e at an
y time an
d with
ou
t o
b
lig
ati
on
o
n C
A
M
E c
an
celli auto
mati
ci
s.p
.a. to n
otify u
se
rs.
ENGLISH