ALIAN
IT
ALIAN
ENGLISH
1 ON - Maintained action - The gate works only by keeping pressedan opening or closing button on terminals2-7 (excludes
functioning with radio command).
2 ON - Automatic closing - The automatic closing timer activates at the closing endpoint. The preset time is adjustable, and is anyway
subordinated by’any safety accessories and is excluded after a total "stop" action or when the power goes out.
6.4 Selecting functions
Trimmer T.C.A.
= Automatic closing time. Adjusts opening waiting time; Once the time is elapsed, a closing run is automatically activated.
The waiting time can be adjusted to between 1 and 120 seconds.
6.5 Adjusting the trimmers
6.8 Motor torque limiter
To change motor torque, move the faston (the one with
the black wire) to one of the four settings: 1 min ÷ 4
max.
White
Red
Black