Functions menu
First of all, program the following functions first: Type of motor, Number of motors, TOTAL STOP
and Self-learning.
DIP-SWITCH
Description of functions
Motor type
By default,the control panel controls OPP001 and FTL20DGC-series gearmotors.
For controlling OPS001, BXL04AGS-series gearmotors.
select the DIP-switches as shown and press the PROG button on the control board. The LED stays on and the
buzzer sounds off for one second.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
Number of motors
By default,two motors are configured.
To configure a single motor:
select the DIP-switches as shown and press the PROG button on the control board. The LED stays on and the
buzzer sounds off for one second.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
TOTAL STOP from button (contact 1-2)
By default,this function is enabled.
To disable it:
select the DIP-switches as shown and press the PROG button on the control board. The LED flashes and the
buzzer sounds off twice.
To return to the default setting, press PROG again. stays on and the buzzer sounds off for one second.
Self-learningof the gate travel (see the Self-learning paragraph)
Select the DIP-switches as shown and press the PROG button on the control board.
The operator will perform a series of maneuvers to establish the limit-switch points. To establish the slow-
down staring points - when opening and closing - press PROG when the gate leaves reach the desired
position.
When calibrating, the PRG LED flashes. When the calibration is complete, the buzzer sounds off for one
seconds.
If the calibration is not successful, the LED flashes quickly and the buzzer sounds off seven times.
You can interrupt the gate travel's self-learning operation by pressing the STOP button (if enabled).
Reopening during closing (contact 2-C1)
By default, the feature is disabled.
To enable it:
select the DIP-switches as shown and press the PROG button on the control board. The LED stays on and
the buzzer sounds for one second.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
Input on contact 2-CX
By default, the feature is disabled.
To enable it:
select the DIP-switches as shown and press the PROG button on the control board. The LED stays on and
the buzzer sounds for one second.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
Partial stop or obstruction wait (contact 2-CX)
By default,the function is set to partial stop.
To enable theOBSTRUCTIONWAIT:
Select the DIP-switches as shown and press the PROG button on the control board. The LED stays on and
the buzzer sounds off for one second.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
OPEN-CLOSE-INVERT or OPEN-STOP-CLOSE-STOP with button (contact 2-7)
By default, the feature is OPEN-CLOSE-INVERT.
To enable it to OPEN-STOP-CLOSE-STOP:
Select the DIP-switches as shown and press the PROG button on the control board. The LED stays on and
the buzzer sounds for one second.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
Содержание 002ZL60
Страница 17: ...EN English FA01040 EN CONTROL PANEL FOR 24 V GEARMOTORS ZL60 INSTALLATION MANUAL...
Страница 33: ...FR Fran ais FA01040 FR ARMOIRE DE COMMANDE POUR MOTOR DUCTEURS 24 V ZL60 MANUEL D INSTALLATION...
Страница 49: ...RU FA01040 RU 24 ZL60...
Страница 50: ...2 FA01040 RU 02 2018 CAME S p A 2006 42 CE 2006 42 CE CAME S p A 1 5...
Страница 51: ...3 FA01040 RU 02 2018 CAME S p A III...
Страница 63: ...15 FA01040 RU 02 2018 CAME S p A PROG 5 PROG 7 5 PROG 5...