INSTALLATION INSTRUCTIONS

CONNECTIONS 

 

 

 

 

        OPERATIONS 

CX-ED2079 ‘Universal’ Electric Strike

Red

Black

Blue

Green

Black

Red

Blue

Green

Black

Red

Blue
Green

(+12V)

( - )

(+24V)

( - )

12V

24V

Varistor  

Varistor  

Power

Power

5. Connections

6. Operation

POWER  

12VDC

 

Red/Black:   +12V 

Blue/Green:   Ground

A varistor is provided to protect/prevent strike from spikes. 

Connect varistor between input wires.

Fail Safe

Changing

Fail Secure

24VDC

 

Red: 

+24V

Black/Blue: 

-

Green: 

Ground

How to modify fail-safe to fail-secure or vice versa.

1. Loosen the screw as per the product diagram below.
2. Rotate the set plate 180° and slide the plate until it

is properly seated.

3. Tighten the screw.

 

Note: For UL 294 / UL 1034 compliance the door strikes 

are to be powered via a UL 294/ UL 603  class 2 power 

limited output from a control panel and or power supply.  

Furthermore, when powered by AC/DC the units shall use a 

UL regulated UL 294/ UL 603  power limited class 2 output 

rated 12/24V with AC on indicator.

Содержание CX-WC13AXFM-PS

Страница 1: ...the PBTN input on its Aura board causing its N O relay contact to send a momentary closure to inside PUSH TO LOCK causing the CX WC13PS to lock the Restroom and switch the Aura colors from green to re...

Страница 2: ...ctivating relay 3 0 15 seconds The fifth option H 3 flashing will be how long relay 3 will be activated for 0 50 seconds See chart below Factory Reset Defaulting the CX 33 To return the CX 33 back to...

Страница 3: ...t and the surface aura enclosure align FOR CM 45 454SE1 CM 45 854SE1 CM 45 4 SWITCHES a Use the 6 32 hex head screws to tighten the aura insert slightly b Fit in the assembled CM 45 4 by locating the...

Страница 4: ...screws to completely tighten in place 4 Place the aura board inside the flush aura enclosure making sure the screw holes on the aura board align with the screw holes inside the Flush aura enclosure Us...

Страница 5: ...screws and lockwashers 6 Secure M5x12 screws holding mounting brackets to jamb 4 Installation Mounting Bracket Spacer Spacer Option Spacer M5x12 Flat Head Screw 2pcs Jamp M5x12 Screw Vertical Centerli...

Страница 6: ...een input wires Fail Safe Changing Fail Secure 24VDC Red 24V Black Blue Green Ground How to modify fail safe to fail secure or vice versa 1 Loosen the screw as per the product diagram below 2 Rotate t...

Страница 7: ...ITTEN PERMISSION OF CAMDEN DOOR CONTROLS IS PROHIBITED Light ring on switch will turn red when door is locked to unlock door and exit TO LOCK THIS DOOR WAIT FOR DOOR TO CLOSE 40 81C021 Place sign on t...

Страница 8: ...lack Vinyl English Label DOOR LOCKED WHEN RED UNLOCKED WHEN GREEN OCCUPIED WHEN RED VACANT WHEN GREEN 9 CM SFF1 Black Vinyl French Label OCCUP LIBRE PORTE BARR E PORTE D BARR E 10 CM SFFE1 Black Vinyl...

Страница 9: ...WC13PS SERIES RESTROOM CONTROL INSTALLATION INSTRUCTIONS Page 9 of 11 File WC13PS Restroom Controls Manual indd Rev February 26 2020 Part No 40 82B238 Questions Call us toll free at 1 877 226 3369 or...

Страница 10: ...gration Model 60 40E033 CM 2520 4855SE1 or similar PUSH TO OPEN PUSH TO LOCK Inside Push To Open always unlocks opens door Push to Lock combination Switch 12 24 Power Remote N O Relay Output Push To O...

Страница 11: ...Page 11 of 11 WC13PS SERIES RESTROOM CONTROL INS TA LLATIO N INS TR UCTIO NS CABINET BASE L C L C 7 7 8 200 2 mm Cabinet Base Mounting Template 6 152 7 mm 6 152 7 mm 9 5 8 243 9 mm 11 1 16 281 4 mm...

Отзывы: